SERIES HFT
IN-LINE FLOW TRANSMITTER
Local Flow Indication, Unrestricted Mounting, 4-20 mA, 0-5 V, and 1-5 V Output
In-Line
Flow Transmitters,
7-1/8
1.0 SP. GR.
[180.98]
FLOW
DIRECTION
3500 PSI/240 BAR MAX
The Series HFT In-Line Flow Transmitter provides continuous monitoring of ow
rate levels via a direct reading in-line owmeter with electronics to provide proportional
4-20 mA, 0-5 and 1-5 VDC analog outputs.
FEATURES/BENEFITS
• Provides analog output to monitor application ow and integral direct
reading scale to provide local indication of ow rate
• Increased application versatility with no inlet or outlet straight plumbing requirement
and can be mounted horizontally, vertically, or inverted
• Outdoor or harsh environment installation capable with rugged cast aluminum
construction and NEMA 4X (IP65) enclosure
APPLICATIONS
• Waste water processing
• Lubrication systems
• Process control
• Solar systems
MODEL CHART - DUAL SCALE RANGE
Model Connection Size
HFT-1112
HFT-1123
OPTIONS
Use order code: Description
NISTCAL-FT1 NIST traceable calibration certicate
1/4˝ female NPT
1/4˝ female NPT
• Drain lines
• Pump testing
• Drive data acquisition devices, meters
or analog input cards
Range, Air:
SCFM, SLPS
2 to 12, 1 to 5.5
4 to 23, 2 to 10
Body
Material
Aluminum
Aluminum
DWYER INSTRUMENTS, INC. 280
2-15/16
[74.61]
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials: Body: Aluminum,
brass or 304 SS; Seals: Buna-N or
Fluoroelastomer; Magnet: PTFE coated
Alnico; Other internal parts: 304 SS.
Viscosity: 500 SSU.
Temperature Limits: 170˚F (76˚C).
Pressure Limits: Aluminum body: 600
psig (41 bar); Brass body: 3500 psig
(240 bar); 304 SS body: 6000 psig (413
bar).
MODEL CHART
Model Connection Size
HFT-2205
HFT-2315
HFT-2320
HFT-2440
HFT-2550
HFT-3202
HFT-3210
USA: California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
1/2˝ female NPT
3/4˝ female NPT
3/4˝ female NPT
1˝ female NPT
1-1/2˝ female NPT
1/2˝ female NPT
1/2˝ female NPT
Range, Water:
GPM, LPM Body Material
0.5 to 5.0, 2 to 19
1 to 15, 5 to 55
2 to 20, 1 to 75
4 to 40, 15 to 150
6 to 50, 20 to 190
.2 to 2, 1 to 8
1 to 10, 3 to 3.75
4-1/2
[114.3]
Power Requirements: 12-35 VDC.
Enclosure Rating: NEMA 4X (IP66).
Accuracy: ±2% FS.
Repeatability: ±1% of FS.
Response Time: < 100 ms.
Output Signal: 4-20 mA; 0-5 V; 1-5 V.
Shipping Weight: 1/4 to 1/2˝ female
NPT models: 3 lb (1.4 kg); 3/4 to 1˝
female NPT models: 4.5 lb (2.0 kg);
1-1/2˝ female NPT models: 12 lb (5.4
kg).
Brass
Brass
Brass
Brass
Brass
304 SS
304 SS