Dwyer Instruments SERIES GFT2 Catalog Page

Totalizers
T R RST
1-1/2
[38.89]
1-1/4
[28.58]
1-9/16
[40.09]
2-61/64
[75.18]
9-PIN FEMALE
I/O PORT
47/64 [18.8]
3
[76.2]
3-13/32
[86.36]
GFT2 FLOW TOTALIZER INPUT/OUTPUT
STATUS
Flowmeters,
Series
GFT2
Flow Totalizer
Graphic LCD, Digital RS-232 or RS-485 Interface
The Series GFT2 Flow Totalizer is a microcontroller driven device designed to linearize the flow meter and controller flow curve plus display the instantaneous flow rate, total, and accumulated total. The totalizer is intended to be used with analog flow meters and controllers with analog 0 to 5 VDC, 0 to 10 VDC, or 4 to 20 mA interface. RS-232 or RS­485 digital interface is available.
FEATURES
• Up to 47 different volumetric and mass flow engineering units (including user­ defined)
• User adjustable LCD back light and contrast level
• Compact design for unit mount, panel mount, wall mount, or field mount applications
• Low and high flow alarms with programmable action delay
• Free configuration and mounting utility software
• 0.51˝ (13 mm) LCD digits for flow rate, and 0.21˝ (5.5 mm) digits for total
228
DWYER INSTRUMENTS, INC.
SPECIFICATIONS Input Analog Range: 0 to 5 VDC, 0 to 10 VDC, or 4 to 20 mA. Accuracy: ±0.1% FS. Operating Temperature: 14 to 158°F (-10 to 70°C). Power Supply: 12 to 26 VDC. Weight: 0.3 lb (125 g).
Model GFT2-05-RS232 GFT2-10-RS232 GFT2-15-RS232 GFT2-05-RS485 GFT2-10-RS485 GFT2-15-RS485
Model GFT2-20C A-645 A-646
Input
0 to 5 VDC 0 to 10 VDC 4 to 20 mA 0 to 5 VDC 0 to 10 VDC 4 to 20 mA
Description
Flow controller mounting kit, power supply Flow controller mounting kit, no cables Flow meter mounting kit, no cables
Serial Communication
RS-232 RS-232 RS-232 RS-485 RS-485 RS-485