Dwyer Instruments SERIES DPM Catalog Page

4-11/32
SERIES DPM
PARTICULATE MONITOR AND CONTROL
Real-Time Leak Gage, Adjustable Alarm Points
PROCESS CONTROL
4-3/8
[11.13]
6-19/64 [159.94]
The Series DPM Particulate Monitor and Control and Series PMS particulate sensor
combine to provide a basic baghouse and cartridge lter leak detector designed for general maintenance planning and process protection. Leakage is gauged in real­time, on-the-spot, without prior baseline data and without signal tuning and displayed
on the digital readout in a bar graph and an absolute digital readout. An alarm point
can be set by simply moving an indicator up and down the gauge with the key pad.
FEATURES/BENEFITS
• Rugged cast aluminum housing with lockable membrane keypad
• Programmable alarm points
• Large LCD to display readouts digitally
APPLICATIONS
• Baghouses
• Bin vents
• Cartridge lters
MODEL CHART Model System Rating Range Input Power DPM-A111 DPM-A112 DPM-A113 DPM-A121 DPM-A122 DPM-A123 DPM-AHZ111 DPM-AHZ112 DPM-AHZ113 DPM-AHZ121 DPM-AHZ122 DPM-AHZ123
*DPM models listed intrinsically safe are to be used with corresponding intrinsically safe PMS models making an intrinsically safe control loop. The PMS model can then be installed in a hazardous location according to approval ratings listed. The DPM itself is not intrinsically safe and must be installed outside the hazardous
location.
Weatherproof/NEMA 4X (IP66) Weatherproof/NEMA 4X (IP66) Weatherproof/NEMA 4X (IP66) Weatherproof/NEMA 4X (IP66) Weatherproof/NEMA 4X (IP66) Weatherproof/NEMA 4X (IP66) Intrinsically safe* Intrinsically safe* Intrinsically safe* Intrinsically safe* Intrinsically safe* Intrinsically safe*
5.0-5000 pA
5.0-5000 pA
5.0-5000 pA
0.5-5000 pA
0.5-5000 pA
0.5-5000 pA
5.0-5000 pA
5.0-5000 pA
5.0-5000 pA
0.5-5000 pA
0.5-5000 pA
0.5-5000 pA
115 VAC 50/60 Hz 230 VAC 50/60 Hz 24 VDC 115 VAC 50/60 Hz 230 VAC 50/60 Hz 24 VDC 115 VAC 50/60 Hz 230 VAC 50/60 Hz 24 VDC 115 VAC 50/60 Hz 230 VAC 50/60 Hz 24 VDC
6-5/16
[160.34]
SPECIFICATIONS Inputs: From PMS sensor. Output Ratings: Alarm relays: 2 form A (SPST) rated 5 A @ 240 V res. (must
provide an 8 A (max) fuse in series with relay load); Analog: 4-20 mA (option RC).
Power Requirements: 115 VAC 50/60 Hz, 230 VAC 50/60 Hz, or 24 VDC. Power Consumption: 6 W max. Accuracy: Standard: ±5% of range, Optional: ±1% of range. Display: LCD. Display Resolution: Standard: 5 pA; Optional: 0.5 pA. Memory Backup: For set point storage only. Temperature Limits: -13 to 160°F (-25 to 70°C). Weight: 4.5 lb (2.0 kg). Enclosure: Cast aluminum, weatherproof, NEMA 4X (IP66). Loop Power Supply (Isolated): 17 VDC loop supply provided by DPM control unit
for PMS sensor. Agency Approvals: CE & CSA.* *DPM models listed intrinsically safe are to be used with corresponding intrinsically safe PMS models making an intrinsically safe control loop. The PMS model can then be installed in a hazardous location according to approval ratings listed. The DPM itself is not intrinsically safe and must be installed outside the hazardous
location.
MOUNTING
4-11/32 [110.33]
MOUNTING
4-3/8
[111.13]
6-19/64 [159.94]
Particulate (Dust or Broken Bag)
Sensors
OPTIONS To order add sufx: Description
-RC Analog output (4-20 mA)
DWYER INSTRUMENTS, INC.
373