Dwyer Instruments SERIES DCT1000DC Catalog Page

[222.25]
2-3/4
®
SERIES DCT1000DC
DUST COLLECTOR TIMER CONTROLLER
For Low Voltage Applications
PROCESS CONTROL
The Series DCT1000DC Dust Collector Timer Controller simplies on-demand cleaning requirements in low voltage applications by eliminating the need for external devices such as pressure switches, relays, and timers. The modular design allows for use as a continuous cleaning control or on-demand cleaning control using the optional plug-in pressure module. The DCT1000 is the same size for 6, 10, and 22 channels, allowing one board size to be the standard on one enclosure.
• 10 to 30 VDC power requirement for low voltage applications
• Standard mounting holes to other dust collector controllers for use in existing installations
• Able to automatically detect any channel expander connected
APPLICATIONS
• Dust collection
• Pneumatic conveying
MODEL CHART Model Description No. of Channels D.P. Range DCT1022DC DCT1010DC DCT1006DC DCP200A DCP100A
Master controller Master controller Master controller Pressure module Pressure module
22 10 6
-
-
-
-
­20 in w.c. 10 in w.c.
6-7/8
[69.85]
1/16
[1.59]
®
6-1/4
[158.75]
[174.62]
8-1/4
[209.55]
8-3/4
SPECIFICATIONS DCT1000DC TIMER CONTROLLER Output Channels: 6, 10, & 22 channels. Power Requirements: 10-30 VDC. Solenoid Supply: 3 A maximum per channel. Fuse: 3 A @ 250 VAC. Temperature Limits: -40 to 140°F (-40 to 60°C). Storage Temperature Limits: -40 to 176°F (-40 to 80°C). On Time: 10 ms to 600 ms, 10 ms steps. On Time Accuracy: ±10 ms. Off Time: 1 s to 255 s, 1 s steps. Off Time Accuracy: ±1% of the value or ±50 ms, whichever is greater. Weight: 1 lb 3.0 oz (538.6 g).
DCP PRESSURE MODULE Pressure Ranges: 10 in w.c. or 20 in w.c. Temperature Limits: -40 to 140°F (-40 to 60°C). Pressure Limit: 10 psi (68.95 kPa). Pressure Limit (differential): 10 psi (68.95 kPa). Accuracy: ±1.5% FS @ 73°F (22.8°C). Output Signal: 4-20 mA. Alarm Contacts: 1.5 A inductive load, 3 A resistive load @ 30 VAC or 40 VDC. Process Connections: Two barbed connections for use with 1/8˝ (3.18 mm) or
3/16˝ (4.76 mm) ID tubing.
Weight: 5.5 oz (155.9 g). Agency Approvals: CE.
Timer Controllers
OPTIONS To order add sufx: Description
-WP
-WPP
-WPPS
-EXPL
ACCESSORIES Model Description DPMA-402 Process indicator
Weatherproof housing only Weatherproof housing with pressure ports Weatherproof housing with pressure ports, three position rotary switch installed Explosion-proof housing
DCT in optional NEMA 4/4X
weatherproof enclosure
DWYER INSTRUMENTS, INC. |
DCT in optional
Explosion-proof enclosure
371