SERIES DCT1000
DUST COLLECTOR TIMER CONTROLLER
Modular Design, User Friendly, Up to 22 Channels
PROCESS CONTROL
8-1/4
[209.55]
8-3/4
[222.25]
6-1/4
[158.75]
6-7/8
[174.62]
[69.85]
1-13/16
[46.04]
1/16
[1.59]
The Series DCT1000 Dust Controller Timer Controller simplies on-demand
cleaning requirements by eliminating the need for external devices such as pressure
switches, relays, and timers. The modular design allows for use as a continuous
cleaning control or on-demand cleaning control using the optional plug-in pressure
module. The DCT1000 is the same size for 6, 10, and 22 channels, allowing one board
size to be the standard on one enclosure.
FEATURES/BENEFITS
• Universal power requirements for both domestic and overseas use
• Standard mounting holes to other dust collector controllers for use in existing
installations
• Able to automatically detect any channel expander connected
APPLICATIONS
• Dust collection
• Pneumatic conveying
Timer Controllers
MODEL CHART
Model Description No. of Channels D.P. Range
DCT1022
DCT1010
DCT1006
DCT1122
DCT1110
DCP200A
DCP100A
Master controller
Master controller
Master controller
Channel expander
Channel expander
Pressure module
Pressure module
22
10
6
22
10
-
-
-
-
-
-
-
20 in w.c.
10 in w.c.
SPECIFICATIONS
DCT1000 TIMER CONTROLLER
Output Channels: 6, 10, & 22 channels.
Expandable to 255 channels using
DCT1122 & DCT1110 channel expander
boards.
Power Requirements: 85-270 VAC, 50
or 60 Hz.
Power Consumption: 5 W.
Solenoid Supply: 3 A max per channel.
Fuse: 3 A @ 250 VAC. Low voltage
control circuitry is isolated from the line
voltage for system safety.
Temperature Limits: -40 to 140°F (-40
to 60°C).
Storage Temperature Limits: -40 to
176°F (-40 to 80°C).
On Time: 10 ms to 600 ms, 10 ms steps.
On Time Accuracy: ±10 ms.
Off Time: 1 s to 255 s, 1 s steps.
Off Time Accuracy: ±1% of the value or
±50 ms, whichever is greater.
Weight: 1 lb 3.0 oz (538.6 g).
Agency Approvals: cULus.
DCP PRESSURE MODULE
Pressure Ranges: 10 in w.c. or 20 in
w.c.
Temperature Limits: -40 to 140°F (-40
to 60°C).
Pressure Limit: 10 psi (68.95 kPa).
Pressure Limit (differential): 10 psi (68.95
kPa).
Accuracy: ±1.5% FS @ 73°F (22.8°C).
Output Signal: 4-20 mA.
Alarm Contacts: 1.5 A inductive load, 3
A resistive load @ 30 VAC or 40 VDC.
Process Connections: Two barbed
connections for use with 1/8˝ (3.18 mm)
or 3/16˝ (4.76 mm) ID tubing.
Weight: 5.5 oz (155.9 g).
OPTIONS
To order add sufx: Description
-WP
-WPP
-WPPS
-EXPL
Note: Multiple boards stacked in enclosure.
ACCESSORIES
Model Description
DPMA-402 Process indicator
Note: DCA channel expander cable
available in 1 ft, 2 ft, and 4 ft lengths.
Weatherproof housing only
Weatherproof housing with pressure ports
Weatherproof housing with pressure ports, three position
rotary switch installed
Explosion-proof housing
DWYER INSTRUMENTS, INC. | 370
DCT in optional NEMA
4/4X weatherproof
enclosure
DCT in optional
Explosion-proof
enclosure
Master board stacked
with channel expander
DCAC02 cable
connection for
connecting multiple
boards