SERIES DA/DS | MERCOID® BY DWYER
BOURDON TUBE PRESSURE SWITCH
Pressure Ranges to 8000 psi (551.6 bar)
PRESSURE
[57.15]
8 [203.20]
3-1/2
[88.90]
3-7/8
[98.43]
1-3/4
[44.45]
10
3/4
CONDUIT
E
O
D
I
V
O
N
L
I
N
Customers tell us that the Series DA/DS Bourdon Tube Pressure Switch is the
best pressure switch made. The Mercoid DA/DS Series is one of the world’s broadest
lines of pressure switches. The DA/DS Series has extremely high sensitivity and
great repeatability. The DA Models are equipped with two external adjustments, one
for setting high pressure operating point, the other for setting low pressure operating
point. Deadband, the difference between high and low setpoints, is adjustable over the
full-scale. The DS Models are equipped with a single external adjustment for setting
operating point only. For mercury-free switches, choose between the snap action
switch or hermetically sealed snap action switch. Hermetically sealed mercury switch
also available.
Single Pressure Switches
FEATURES/BENEFITS
• Visible calibrated dial provides an easy and fast check without having to open device
causing dangerous conditions to operators
• On/off indication (except hermetically sealed snap switch models) gives operator
clear indication of state of switched equipment that could be located in another
location
• Adjustableorxeddeadbandsupportscontrolapplicationsbyreducingequipment
wear-out by unnecessary recycling
• External switch set point adjustment reduces set-up time
• Pressure ranges of full vacuum to 8000 psig gives application designers the ability to
specify standard equipment, simplifying install and training, and reducing servicing
costs
• UL listed, CSA approved, many models FM approved to support rigorous process
applications and regulations
• General purpose, weatherproof or explosion-proof enclosures for a variety of indoor
or outdoor environments meeting the needs of multiple applications and uses
APPLICATIONS
• Compressors
• Mechanical HVAC or process equipment
• Pump control
7-3/4 [196.9]
Ø6-1/64
[152.8]
1/4 NPT
3-1/2
[88.90]
[2] STD.
Ø13/32
MOUNTING
HOLES
"U"
"L"
1/2
NPT
DAH DAW
CONDUIT HOLE
CONTROL
ADJUSTMENTS
SPECIFICATIONS
Wetted Materials: Brass, 403 SS, or 316 SS.
Temperature Limit: 180°F (82°C).
Pressure Limit: Maximum pressure of the operating range.
Enclosure Rating: General purpose, weatherproof or explosion-proof.
Repeatability: ±1% of full operating range, ±1.5% on DS-7300 models.
Switch Type: SPST mercury switch, SPDT mercury switch, SPDT snap switch, or
SPDT hermetically sealed snap switch. Other circuit types available.
Electrical Rating: See model charts.
Electrical Connections: Screw terminal.
Conduit Connection: Generalpurpose:1/2˝holeforconduithub;Weatherproof:
1/2˝conduithub;Explosion-proof:3/4˝femaleNPT.
Process Connection: Generalpurposeandweatherproof:1/4˝maleNPT,1/2˝
maleNPTonranges15Sand16S;Explosion-proof:1/2˝maleNPTand1/4˝female
NPT.
Mounting Orientation: Vertical.
Set Point Adjustment: Thumbscrew.
Weight: Generalpurpose:4lb(1.8kg);Weatherproof:6lb(2.7kg);Explosion-
proof: 8 lb (3.5 kg).
Deadband: See model chart.
Agency Approvals: CSA, FM, UL (mercury switch units are not CE approved)
(Consult factory for FM approved models).
7/8
[22.23]
5-3/8
[134.97]
3/4 PIPE THD.
1-5/8
[41.28]
ADJUSTMENT
SCREWS
REAR MOUNTING
2-3/4
[69.08]
1-1/4
[30.40]
FLANGE [3] .203 [5.16]
DIA HOLES AT 120° ON
6-1/2 [165.1] DIA. BOLT CIRCLE
5/8
[15.82]
ADJUSTMENTS
1/4
NPT
1/2˝ CONDUIT HOLE
5/8
[15.88]
GASKETED
COVER
GASKET
3-5/8
[92.27]
[26.39]
2-7/8
[71.63]
7
[177.80]
1-5/8
8
[201.79]
1/2˝
CONDUIT
1
HUB
USA: California Proposition 65
DWYER INSTRUMENTS, INC. | 90
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
®
SERIES DA/DS | MERCOID® BY DWYER
BOURDON TUBE PRESSURE SWITCH
Pressure Ranges to 8000 psi (551.6 bar)
PRESSURE
MODEL CHART - D SERIES PRESSURE SWITCH WITH SNAP ACTION SWITCH AND GENERAL PURPOSE ENCLOSURE
Bourdon
Tube
Material
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
Adjustable
Operating
Range (psig)
0 to 30˝ Hg VAC
10˝ Hg VAC to 12
25˝ Hg VAC to 50
1/8 to 15
1/8 to 20
1 to 35
2 to 60
5 to 100
5 to 150
10 to 200
10 to 300
30˝ Hg VAC to 60
30˝ Hg VAC to 75
2 to 60
5 to 100
10 to 200
10 to 300
40 to 350
25 to 600
50 to 1000
100 to 1500
300 to 2500
500 to 5000
800 to 8000
30˝ Hg VAC to 75
5 to 75
10 to100
10 to 150
10 to 300
30 to 400
75 to 800
100 to 1000
200 to 2500
Adjustable Deadband
SPDT: 10 A @ 120/240 VAC
Minimum
Deadband
(psig) Model Fixed Model Fixed Model
13.5˝ Hg
6
12
6
6
7.5
9
13.5
24
24
37.5
18
22.5
13.5
19.5
22.5
28.5
30
67.5
142.5
195
390
1350
2250
15
12
15
16.5
42
78
180
285
600
DA-7031-153-2
DA-7031-153-3
DA-7031-153-27
DA-7031-153-1
DA-7031-153-3A
DA-7031-153-4
DA-7031-153-5
DA-7031-153-6
DA-7031-153-7
DA-7031-153-8
DA-7031-153-9
DA-7021-153-25S
DA-7021-153-26S
DA-7021-153-5S
DA-7021-153-6S
DA-7021-153-8S
DA-7021-153-9S
DA-7021-153-9AS
DA-7021-153-10S
DA-7021-153-11S
DA-7021-153-12S
DA-7021-153-13S
DA-7021-153-15S
DA-7021-153-16S
DA-7041-153-26E
DA-7041-153-23E
DA-7041-153-6E
DA-7041-153-24E
DA-7041-153-9E
DA-7041-153-21E
DA-7041-153-22E
DA-7041-153-11E
DA-7041-153-13E
Fixed Deadband
SPDT: 15 A @ 120/240 AC
3˝ Hg
1.5
2.5
1.5
1.5
1.5
2
2.5
3
4
5
3.5
3
3.5
4
6
6
10
20
30
60
200
500
3.5
4
3.5
4
8
10
25
35
75
DS-7231-153-2
DS-7231-153-3
DS-7231-153-27
DS-7231-153-1
DS-7231-153-3A
DS-7231-153-4
DS-7231-153-5
DS-7231-153-6
DS-7231-153-7
DS-7231-153-8
DS-7231-153-9
DS-7221-153-25S
DS-7221-153-26S
DS-7221-153-5S
DS-7221-153-6S
DS-7221-153-8S
DS-7221-153-9S
DS-7221-153-9AS
DS-7221-153-10S
DS-7221-153-11S
DS-7221-153-12S
DS-7221-153-13S
DS-7221-153-15S
DS-7221-153-16S
DS-7241-153-26E
DS-7241-153-23E
DS-7241-153-6E
DS-7241-153-24E
DS-7241-153-9E
DS-7241-153-21E
DS-7241-153-22E
DS-7241-153-11E
DS-7241-153-13E
Hermetically Sealed, Fixed Deadband
SPDT: 5 A @ 120/240 VAC, 5 A res. @ 30 VDC
5˝ Hg
3
3.75
3
3
3
3
3.75
5.25
6.75
9
5.25
5.25
4.5
5.25
7.125
10.5
10.5
18
33
52.5
90
300
5.25
6
5.25
6.75
12
18
37.5
52.5
112.5
DS-7331-153-2
DS-7331-153-3
DS-7331-153-27
DS-7331-153-1
DS-7331-153-3A
DS-7331-153-4
DS-7331-153-5
DS-7331-153-6
DS-7331-153-7
DS-7331-153-8
DS-7331-153-9
DS-7321-153-25S
DS-7321-153-26S
DS-7321-153-5S
DS-7321-153-6S
DS-7321-153-8S
DS-7321-153-9S
DS-7321-153-9AS
DS-7321-153-10S
DS-7321-153-11S
DS-7321-153-12S
DS-7321-153-13S
DS-7321-153-15S
DS-7341-153-26E
DS-7341-153-23E
DS-7341-153-6E
DS-7341-153-24E
DS-7341-153-9E
DS-7341-153-21E
DS-7341-153-22E
DS-7341-153-11E
DS-7341-153-13E
Single Pressure Switches
MODEL CHART - D SERIES PRESSURE SWITCH WITH MERCURY SWITCH AND GENERAL PURPOSE ENCLOSURE
Bourdon
Tube
Material
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
403 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
Adjustable
Operating
Range (psig)
30˝ to 0 Hg VAC
10˝ Hg VAC to 12
25˝ Hg VAC to 50
1/8 to 15
1/8 to 20
1 to 35
2 to 60
5 to 100
5 to 150
10 to 200
10 to 300
30˝ Hg VAC to 60
30˝ Hg VAC to 75
2 to 60
5 to 100
10 to 200
10 to 300
40 to 350
25 to 600
50 to 1000
100 to 1500
300 to 2500
500 to 5000
800 to 8000
30˝ Hg VAC to 75
5 to 75
10 to100
10 to 150
10 to 300
30 to 400
75 to 800
100 to 1000
200 to 2500
Adjustable Deadband
Minimum
Deadband
(psig)
2˝ Hg
1
3.5
1
1
1.75
3
3.75
6
8
12
6
8
4
6
8
14
14
25
60
90
150
450
750
7
3
7
6
18
30
75
100
210
SPDT
4 A @ 120 V,
2 A @ 240 V
AC/DC
DA-31-153-2
DA-31-153-3
DA-31-153-27
DA-31-153-1
DA-31-153-3A
DA-31-153-4
DA-31-153-5
DA-31-153-6
DA-31-153-7
DA-31-153-8
DA-31-153-9
DA-21-153-25S
DA-21-153-26S
DA-21-153-5S
DA-21-153-6S
DA-21-153-8S
DA-21-153-9S
DA-21-153-9AS
DA-21-153-10S
DA-21-153-11S
DA-21-153-12S
DA-21-153-13S
DA-21-153-15S
DA-21-153-16S
DA-41-153-26E
DA-41-153-23E
DA-41-153-6E
DA-41-153-24E
DA-41-153-9E
DA-41-153-21E
DA-41-153-22E
DA-41-153-11E
DA-41-153-13E
SPST
Open on Increase
10 A @ 120 V,
5 A @ 240 V
AC/DC
DA-31-2-2
DA-31-2-3
DA-31-2-27
DA-31-2-1
DA-31-2-3A
DA-31-2-4
DA-31-2-5
DA-31-2-6
DA-31-2-7
DA-31-2-8
DA-31-2-9
DA-21-2-25S
DA-21-2-26S
DA-21-2-5S
DA-21-2-6S
DA-21-2-8S
DA-21-2-9S
DA-21-2-9AS
DA-21-2-10S
DA-21-2-11S
DA-21-2-12S
DA-21-2-13S
DA-21-2-15S
DA-21-2-16S
DA-41-2-26E
DA-41-2-23E
DA-41-2-6E
DA-41-2-24E
DA-41-2-9E
DA-41-2-21E
DA-41-2-22E
DA-41-2-11E
DA-41-2-13E
SPST
Close on Increase 10
A @ 120 V
5 A @ 240 V
AC/DC
DA-31-3-2
DA-31-3-3
DA-31-3-27
DA-31-3-1
DA-31-3-3A
DA-31-3-4
DA-31-3-5
DA-31-3-6
DA-31-3-7
DA-31-3-8
DA-31-3-9
DA-21-3-25S
DA-21-3-26S
DA-21-3-5S
DA-21-3-6S
DA-21-3-8S
DA-21-3-9S
DA-21-3-9AS
DA-21-3-10S
DA-21-3-11S
DA-21-3-12S
DA-21-3-13S
DA-21-3-15S
DA-21-3-16S
DA-41-3-26E
DA-41-3-23E
DA-41-3-6E
DA-41-3-24E
DA-41-3-9E
DA-41-3-21E
DA-41-3-22E
DA-41-3-11E
DA-41-3-13E
OPTIONS
Weatherproof Enclosure - Series DAW
Note: To order, add “W” to model number after
DA or DS, change 1 to 3.
Example: DAW-33-153-7
Explosion-Proof Enclosure - Series DAH
Suitable for Class I, Groups C and D; NEMA 7;
Class II, Groups E, F, G; Class III NEMA 9 and
9A, Division 1.
Note: To order, add “H” to model number after
DA or DS. Example: DAH-31-153-7
FM Approved
For general purpose and explosion-proof models
see agency approvals.
Note: To order, add “F” to model number after
DA, DS, DAH or DSH.
Examples: DAF-31-153-7 or DAHF-31-153-7
Other Options (Consult Factory)
DPDT switches or other switch types, xed
deadband mercury switch units for low deadband
applications, manual reset operation, twostage operation, acetal bushed movement for
applications with high amounts of vibration and/
or pulsation, fungus proong, siphon, diaphragm
seals, mounting ange and remote connection.
USA: California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
DWYER INSTRUMENTS, INC. |