Dwyer Instruments SERIES CCT40, SERIES CCT50 Catalog Page

[102.00]
Ø13/64
]
3-1/2
[25.00]
[102.00]
[17.00]
Ø13/64
]
3-1/2
[25.00]
SERIES CCT40/50
PROCESS CONTROL
CURRENT TRANSFORMERS
Solid or Split Core, Field Selectable Range
The Series CCT40/50 Current Transformers are a low cost alternative for measuring power and monitoring the operation of fans, pumps, or other equipment. For use on existing installations, split core models can be installed without disconnecting cables. Each model offers three jumper selectable ranges and a choice of three different outputs.
FEATURES/BENEFITS
• Integral mounting ange for quick installation
• Solid core or split core congurations
• Jumper selectable range
MODEL CHART Model Range Output Power Requirements Case CCT40-202
CCT50-202 CCT40-102 CCT50-102 CCT40-203 CCT50-203 CCT40-200 CCT50-200 CCT40-100 CCT50-100
10/20/50 A 100/150/200 A 10/20/50 A 100/150/200 A 10/20/50 A 100/150/200 A 10/20/50 A 100/150/200 A 10/20/50 A 100/150/200 A
0-5 V 0-5 V 0-5 V 0-5 V 0-10 V 0-10 V 4-20 mA 4-20 mA 4-20 mA 4-20 mA
Self-powered Self-powered Self-powered Self-powered Self-powered Self-powered 15 to 42 VDC, loop powered 15 to 42 VDC, loop powered 15 to 42 VDC, loop powered 15 to 42 VDC, loop powered
APPLICATIONS
• BAS
• HVAC
Solid core Solid core Split core Split core Solid core Solid core Solid core Solid core Split core Split core
YEAR LIMITED
WARRANTY
33/64
[13.00]
2-7/16
[62.00]
2X Ø13/64
[Ø5.00]
45/64
[18.00]
1-17/64
[32.00]
55/64
[22.00]
19/32
[15.00]
2-29/32
63/64
33/64
[13.00]
1-9/64
[29.00]
55/64
[22.00]
SPECIFICATIONS Amperage Range: Field selectable; up to 200 A (depending on model).
Output: 0-5 V, 0-10 V, or 4-20 mA (depending on model). Power Requirements: Self-powered or 15-42 VDC loop powered (depending on
model).
Accuracy: 1%. Temperature Limits: -22 to 158°F (-30 to 70°C). Humidity Limits: 0 to 95% (non-condensing). Response Time: 250 ms to 90%. Isolation Voltage: 2000 V. Frequency: 10 to 400 Hz. Enclosure Rating: UL 94 V-0 ammability rated, ABS plastic housing. Agency Approvals: CE, cULus.
[74.00]
2-31/64 [63.00]
[Ø19.00]
3-1/2
[89.00]
Solid
Ø3/4
55/64
[22.00]
[89.00]
2-3/4
[70.00]
4-1/64
Split
[Ø5.00
2-33/64 [64.00]
2X
43/64
Current Transformers/
SERIES CCT60/70
TRUE RMS CURRENT TRANSFORMERS
Solid or Split Core, Field Selectable Range
The Series providing true RMS outputs on distorted AC waveforms. True RMS outputs are ideal for nonlinear loads or noisy circuits. For existing installations, split core models can be installed without disconnecting cables. Each model offers three jumper selectable
ranges to reduce the risk of ordering the wrong model.
FEATURES/BENEFITS
• Integral mounting ange for quick installation
• Solid core or split core congurations
• Jumper selectable range
• True RMS
MODEL CHART Model Range Case CCT60-200
CCT70-200 CCT60-100 CCT70-100
CCT60/70 True RMS Current Transformers are a low cost alternative for
APPLICATIONS
• BAS
• HVAC
10/20/50 A 100/150/200 A 10/20/50 A 100/150/200 A
Solid core Solid core Split core Split core
[18.00]
33/64
[13.00]
2-7/16 [62.00]
2X Ø13/64
[Ø5.00]
45/64
1-17/64 [32.00]
55/64
[22.00]
19/32
[15.00]
2-29/32
63/64
33/64
[13.00]
1-9/64 [29.00]
55/64
[22.00]
SPECIFICATIONS Amperage Range: Up to 200 A (depending on model).
Output: 4-20 mA, true RMS. Power Requirements: 24 VDC nominal. Accuracy: 1%. Temperature Limits: -22 to 158°F (-30 to 70°C). Humidity Limits: 0 to 95% (non-condensing). Response Time: 250 ms to 90%. Isolation Voltage: 2000 V. Frequency: 10 to 400 Hz. Enclosure Rating: UL 94 V-0 ammability rated, ABS plastic housing. Agency Approvals: CE, cULus.
[74.00]
2-31/64
[63.00]
[Ø19.00]
3-1/2
[89.00]
Solid
Ø3/4
55/64
[22.00]
[89.00]
2-3/4
[70.00]
4-1/64
Split
[Ø5.00
2-33/64
[64.00]
YEAR LIMITED
WARRANTY
2X
43/64
[17.00]