Dwyer Instruments SERIES BTT Catalog Page

3-21/32
1-1/16
3X-5/32
1-3/32
3-21/32
[92.96]
3-9/16
[90.42]
1-1/16 [27.05]
3X-3/8
[9.36]
21/64 [8.38]
1-3/16 [30.00]
1-5/32 [29.39]
3X-5/32
[3.87]
E
CONNECTOR
8-51/64 [223.58]
3-55/64
[98.06]
ø5-7/64
[ø129.59]
7-3/32
[180.18]
CONNECTOR
ø3-5/16
2-13/16
4-21/64
GASKET
BALL CHAIN CONNECTOR
BALL CHAIN CONNECTOR
1/8 [3.30] GASKET
8-51/64 [223.58]
3-55/64
[98.06]
ø5-7/64
[ø129.59]
ø3-5/16 [ø84.08]
PROBE
LENGTH
2-51/64
[71.09]
4-19/64
[109.29]
4-3/64
[102.94]
2-15/64 [56.63]
7-3/32
[180.18]
2X ø13/64
[ø5.08]
SLOT
ø3-5/16
[ø84.07]
2-13/16
[71.48]
PROBE
LENGTH
1/8 [3.30] GASKET
2-15/64
ø5-7/64
E
SERIES BTT
TEMPERATURE TRANSMITTERS
Current or Voltage Output, NEMA 4X Enclosures
4-19/64 [109.29]
4-3/64
[102.94]
BALL CHAIN
Duct mount
2X ø13/64
[ø5.08]
SLOT
ø3-5/16
[ø84.07]
[84.14]
E
O
D
I
V
O
N
L
I
N
Immersion mount
The Series BTT Temperature Transmitters offer transmitter output signals with
the same form and t as our popular TE thermistor and RTD sensors for building
HVAC applications. Thermowells are required when using immersion models in liquid applications.
FEATURES/BENEFITS
• Duct, immersion, and outside air models available
• Radiation shield available for mounting in direct sunlight
• Transmitter output allows for longer wire runs than standard thermistor sensors
APPLICATIONS
• Building automation system temperature monitoring
MODEL CHART
Example BTT -D 04 -1 BTT-D04-1 Series BTT Temperature transmitter Mounting
CongurationDI
Probe Length*
Output 1
Options Blank
*For BTT-I models, actual probe length is approximately 0.75˝ longer than listed probe length to ensure maximum immersion into thermowells.
O
R
Duct mount Immersion mount
Outside air
25
04
06 08 12 18
Outside air with radiation shield
2.5˝ (required for “O” and “R” models) 4˝ 6˝ 8˝ 12˝ 18˝ 4-20 mA
2
0-10 V None
FC
Factory calibration certicate
NIST
NIST calibration certicate
2-51/64
[71.09]
BALL CHAIN
[71.44]
PROBE
LENGTH
1/8 [3.30] GASKET
1/8 [ø3.18]
Outside air without
[109.93]
ø47/64 [18.65]
1/2 NPS
radiation shield
Outside air with radiation shield
5-1/8
[130.00]
3-45/64
94.00
6-47/64
170.90
[ø129.59]
[56.60]
3-55/64
[98.06]
8-51/64 [223.58]
2X ø13/64
[ø5.00]
3-7/64 [79.00]
27/32
[21.50]
7-3/32
[180.18]
4-17/32 [115.00]
115
79
90
2-15/64 [56.63]
SPECIFICATIONS Temperature Sensor: Pt1000 RTD.
Range: -40 to 140°F (-40 to 60°C). Temperature Limits: Operating: -40 to 302°F (-40 to 150°C). Accuracy: ±0.5°C @ 25°C. Thermal Effect: ±0.01%/°C. Response Time: 100 ms. Wetted Materials: All models: 304 SS (probe), polycarbonate (housing); Duct and
immersion models: Neoprene (gasket); Outside air models: Nylon (insert), silocone (O-ring).
Process Connection: 1/2˝ NPS (immersion models only). Electrical Connection: Removable terminal block, knocks out for conduit tting. Conduit Connection: 1/2˝ NPT. Probe Lengths: 2.5 to 18˝ (depending on conguration). Power Requirements: 13-36 VDC for current models, 13-36 VDC or 16-28 VAC for
voltage models.
Output Signal: 4-20 mA or 0-10 VDC (depending on model). Enclosure Rating: NEMA 4X (IP66) (immersions models require thermowell). Weight: 5.11 oz (145 g) (duct/immersion); 8.4 oz (238 g) (OSA without radiation
shield); 1 lb 7.4 oz (663.4 g) (OSA with radiation shield).
Agency Approvals: CE.
THERMOWELLS - WELDED
Model Material TE-TNS-N253N-00 TE-TNS-N043N-00 TE-TNS-N063N-00 TE-TNS-N083N-00 TE-TNS-N123N-00 TE-TNS-N183N-00
304 SS 304 SS 304 SS 304 SS 304 SS 304 SS
Connection (Internal/External)
1/2˝ NPSM/1/2˝ NPT 1/2˝ NPSM/1/2˝ NPT 1/2˝ NPSM/1/2˝ NPT 1/2˝ NPSM/1/2˝ NPT 1/2˝ NPSM/1/2˝ NPT 1/2˝ NPSM/1/2˝ NPT
Insertion Length
2.5˝ 4˝ 6˝ 8˝ 12˝ 18˝
DWYER INSTRUMENTS, INC. |
50
YEAR LIMITED
WARRANTY
Temperature Transmitters
133
Loading...