MODEL CHART
Example AP - - 153 - 36
Construction AP
Reset
Options
Housing
Options
Circuit
(Switching)
Options
Wetted
Materials
Adjustable
Pressure
Ranges
and Maximum
Operating
Pressures
*See chart below
AS
F
R
R
S
WT
W
H
-
-
-
-
-
-
-
70__
70__
80__
__
41
7021
8021
7041
8041
ULManual reset - operates on decrease automatically. NEMA-1 only.
2
3
26
36
88
89
153
( )
153
804
153
AP-153-36 Pressure Control, xed deadband, automatic reset, SPDT mercury switch, adjustable
range 1-20 psig (0.07-1.4 bar), maximum pressure 60 psig (4.1 bar)
General purpose enclosure, NEMA-1.
Low pressure steam switch, NEMA-1, range 34 only. Circuits, 2, 3, 26, 36, 153 only.
PTFE covered diaphragm, plated steel pressure port.
Factory mutual approved, NEMA-1, circuit 153 only. Range 37 only.
APF-153-37 or APF-7021-153-37 only.
Not available with circuit 88, 89 or snap switch type.
Manual reset - operates on increase automatically. NEMA-1 only.
Not available with circuit 88, 89 or snap switch type.
Less enclosure
Weather-proof enclosure, NEMA-4.
Weather-proof enclosure with condensate drain, NEMA-2, 3R.
Explosion-proof enclosure, NEMA-7, 9, Class I Group, C & D; Class II Group E, F & G.
SPST mercury switch, Electrical code P* - opens on pressure increase.
SPST mercury switch, Electrical code P*- closes on pressure increase.
SPST mercury switch, Electircal code R* - closes on pressure increase.
Not available with range 33.
SPST mercury switch, Electrical code R* - opens on pressure increase.
Not available with range 33.
SPST magnetic mercury switch, Electrical code T* - closes on pressure increase.
SPST magnetic mercury switch, Electrical code T* - opens on pressure increase.
SPDT mercury switch, Electrical code S*.
Other circuits available, consult factory.
SPDT snap acting switch, rated 15A at 120 VAC, 8A at 240 VAC, 0.5A at 120 VDC, 0.25A at 240 VDC, 3/4
hp at 120 VAC, 1 hp at 240 VAC.
DPDT: 2 each SPDT snap acting switches, rated 5A at 120/240 VAC, 5A at 30 VDC resistive
SPDT snap acting switch, rated 15A at 120 VAC, 8A at 240 VAC, 4A at 480 VAC, 6A at 24 VDC resistive,
0.5A at 120 VDC, 0.25A at 240 VAC, 3/4 hp at 120 VAC, 1.5 hp at 240 VAC.
Mercury switch type. Plated steel pressure port, Buna-N diaphragm.
Mercury switch type. 316 SS pressure port, PTFE diaphragm.
Snap switch type. Plated steel pressure port, Buna-N diaphragm.
Snap switch type. Plated steel pressure port, Buna-N diaphragm.
Snap switch type, 316 SS pressure port, PTFE diaphragm.
Snap switch type, 316 SS pressure port, PTFE diaphragm.
33
Adjustable range 10˝ wc VAC -50 in w.c (250 mm VAC to 1250 mm w.c.), maximum pressure 15 psig.
Adjustable range 1-15 psig (0.07 to bar), AS only, maximum pressure 30 psig (2.1 bar), maximum
34
temperature 275°F (135°C) psig.
36
Adjustable range 1-20 psig (0.07-1.4 bar), maximum pressure 60 psig (4.1 bar).
37
Adjustable range 1-30 psig (0.07-2.1 bar), maximum pressure 60 psig (4.1 bar).
39
Adjustable range 10-125 psig (0.7-8.6 bar), maximum pressure 160 psig (11 bar).
UL
UL
UL FM
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
ELECTRICAL RATING MERCURY SWITCH
Circuit
Code
Sufx No.
P -2, -3 10A 5A 3A 10A 5A 3/4 1/3
R -26, -36 17A AT 120/240/277 VAC, Resistive balance same as above.
S -153 4A 2A NA 4A 2A 1/8 NA
T -88,-89 0.5A 0.25A NA 0.125A 0.125A
AC Capacity DC Capacity Horsepower
120V 240V 440V 120V 240V AC DC