Dwyer Instruments SERIES ADPS, SERIES EDPS, SERIES BDPA Catalog Page

2-9/16 [65]
2-17/64
SERIES ADPS/EDPS/BDPA
E
[P1]
[P2]
2-9/16 [65]
[P1]
[P2]
2-9/16 [65]
PRESSURE
HVAC DIFFERENTIAL PRESSURE SWITCHES
With Dual Scale Field Adjustable Set Point Knob
Audible
buzzer
Power
input
ADPS
E
O
D
I
V
O
N
L
I
N
EDPS
Ø11/64 [Ø4.5]
IP 54
CABLE GLAND INSERT
21/64 [8.5]
51/64 [18]
2-1/4 [57]
-
+
45/64 [18]
2-21/64
[59]
9/32 [7]
BDPA
EDPS
The Series ADPS/EDPS/BDPA HVAC Differential Pressure Switches are designed for pressure, vacuum, and differential pressures. The dual scaled adjustment knob in inches water column and pascals allows changes to the switching pressure to be made without a pressure gage. The ADPS/EDPS/BDPA are available with settings from 0.08 in w.c. (20 Pa) up to 20 in w.c. (5000 Pa). The silicone diaphragm and PA 6.6 body make the series ADPS ideal for use with air and other noncombustible gases. Series EDPS models meet UL508 and are constructed of plenum rated plastics. The series
BDPA Adjustable Differential Pressure Alarms offer a versatile range of congurations allowing utilization of their many features including buzzer and LED notication, and
battery or line powered. The compact size, adjustment knob and low cost make the ADPS/EDPS/BDPA the perfect choice for HVAC applications.
FEATURES/BENEFITS
• Adjustment knob changes switching pressure easily with a pressure gage reducing components for application
• Low cost device makes it an excellent solution in BAS and HVAC applications requiring duct control and monitoring
• Relay contact allows simple integration with DDC or building systems
APPLICATIONS
• Air lter and ventilator monitoring
• Industrial cooling circuits
• Fire-protection damper control
• Ventilation duct monitoring
• Fan heater overheating protection
• Heat exchanger frost protection
MODEL CHART - ADPS
Model ADPS-08-2-N ADPS-04-2-N ADPS-03-2-N ADPS-05-2-N ADPS-06-2-N ADPS-07-2-N Note: For optional 1/2˝ NPT conduit connection, change -2-N to-1-N. Models that include installer kit
add -C to the end of the model number (-2-N cable gland models only). Installer kit includes two static
tips and 7 ft of PVC tubing. Order installer kit separately with 1/2˝ NPT conduit connection models.
See A-481 in the accessories list. Consult factory for bulk packaging option.
Set Point Range in w.c. (Pa)
0.08 to 1.20 (20-300)
0.12 to 1.60 (30-400)
0.20 to 2.00 (50-500)
0.80 to 4.00 (200-1000)
2.00 to 10.00 (500-2500)
4.00 to 20.00 (1000-5000)
Approx. Dead Band @ Min Set Point in w.c. (Pa)
0.04 (10)
0.06 (15)
0.08 (20)
0.4 (100)
0.6 (150)
1.0 (250)
MODEL CHART - EDPS
Model EDPS-08-1-N EDPS-04-1-N EDPS-03-1-N EDPS-05-1-N EDPS-06-1-N EDPS-07-1-N Note: For optional M20 cable gland connection, change -1-N to-2-N.
MODEL CHART - BDPA
Model BDPA-08-2-N
BDPA-04-2-N BDPA-03-2-N BDPA-05-2-N BDPA-06-2-N BDPA-07-2-N
Set Point Range in w.c. (Pa)
0.08 to 1.20 (20-300)
0.12 to 1.60 (30-400)
0.20 to 2.00 (50-500)
0.80 to 4.00 (200-1000)
2.00 to 10.00 (500-2500)
4.00 to 20.00 (1000-5000)
Set Point Range in w.c. (Pa)
0.08 to 1.20 (20 to 300)
0.12 to 1.60 (30 to 400)
0.20 to 2.00 (50 to 500)
0.80 to 4.00 (200 to 1000)
2.00 to 10.00 (500 to 2500)
4.00 to 20.00 (1000 to 5000)
Approx. Dead Band @ Min Set Point in w.c. (Pa)
0.04 (10)
0.06 (15)
0.08 (20)
0.4 (100)
0.6 (150)
1.0 (250)
Approx. Dead Band @ Min Set Point in w.c. (Pa)
0.04 (10)
0.06 (15)
0.08 (20)
0.4 (100)
0.6 (150)
1.0 (250)
LED
Test/snooze button Battery
Contact output
1-31/32
[50]
Ø15/64 [Ø6]
SPECIFICATIONS Service: Air and non-combustible,
compatible gases. Wetted Materials: ADPS: Diaphragm material: Silicone; Housing material: POM; Switch body: PA 6.6; Cover: Polystyrene; EDPS: Diaphragm material: Silicone; Housing material: Switch body: PA 6.6; Cover: Polystyrene; Materials UL 94 V-0 rated. Temperature Limits: Process and ambient temperature from -4 to 185°F (-20 to 85°C).
Storage: -40 to 185°F (-40 to 85°C). Pressure Limits: Max. operating
pressure: 40 in w.c. (10 kPa) for all pressure ranges. Switch Type: Single-pole double-throw (SPDT).
Approx. Deadband @ Max Set Point in w.c. (Pa)
0.05 (12)
0.09 (23)
0.09 (23)
0.5 (130)
0.8 (200)
1.4 (350)
Approx. Dead Band @ Max Set Point in w.c. (Pa)
0.05 (12)
0.09 (23)
0.09 (23)
0.5 (130)
0.8 (200)
1.4 (350)
Approx. Dead Band @ Max Set Point in w.c. (Pa)
0.05 (12)
0.09 (23)
0.09 (23)
0.5 (130)
0.8 (200)
1.4 (350)
CABLE GLAND INSERT
IP 54
Ø11/64
[Ø4.5]
Ø11/64 [Ø4.5]
21/64 [8.5]
51/64 [18]
21/64
[8.5]
51/64 [18]
[P2] -+ [P1]
ACCESSORIES Model Description A-288
A-289 A-480 A-481
A-489
2-1/4 [57]
-
+
45/64 [18]
2-21/64
[59]
9/32 [7]
1-31/32
[50]
Ø15/64 [Ø6]
ADPS
[57.5]
7/8
[22]
2-21/64
[59]
19/64 [7.5]
1-31/32
[50]
Ø15/64
[Ø6]
BDPA
Electrical Rating: Max. 1.5 A res./0.4 A
ind./250 VAC, 50/60 Hz; Max. switching rate: 6 cycles/min. Electrical Connections: Push-on screw terminals. M20x1.5 with cable strain
relief or optional 1/2˝ NPT. Process Connections: 5/16˝ (7.94 mm) outside diameter tubing, 1/4˝ (6.0 mm)
inside diameter tubing. Enclosure Rating: NEMA 13 (IP54). Mounting Orientation: Vertically,
with pressure connections pointing downwards. Mechanical Working Life: Over 10 switching operations.
Weight: 4.4 oz (125 g). Agency Approvals: ETL approved to
UL508 and CSA C22.2#14 (EDPS only).
“L” type metal mounting bracket with screws “S” type metal mounting bracket with screws Plastic static pressure tip Installer kit, includes 2 plastic static pressure
tips & 7´ (2.1 m) of PVC tubing 4˝ straight static pressure tip with ange
A-480
YEAR LIMITED
WARRANTY
6
Differential Pressure Switches
DWYER INSTRUMENTS, INC.
45
Loading...