29/32
[23.10]
1-5/32
[29.36]
1-9/32
[32.54]
1/4
[6.35]
1/64
[0.51]
WARNING: DO NOT DISCONNECT
WHEN CIRCUIT IS LIVE UNLESS
AREA IS KNOWN TO BE
NON-HAZARDOUS
QUALIFIED FOR CLASS 1
DIVISION 2. GROUPS A, B, C, D
HAZARDOUS LOCATIONS
WHEN USED WITH APPROVED
SOCKETS. USE HOLD DOWN
CLIP WHEN SOCKET MOUNTED
T-CODE T4A
BOTTOM VIEW
CONTACTS
5 AMP 120/240 VAC, 30 VDC
IND. CONT. EQ.
FOR USE IN
HAZARDOUS LOCATIONS
31BN
CHINA
D932ADL
782XDXH21-
XXX VXC
11/16
[17.60]
3-41/64
[92.40]
9/16
[14.30]
1-13/32
[35.60]
9/64
[3.40]
1-23/64
[34.60]
5/8
[16.00]
3-35/64
[90.00]
2-5/8
[66.80]
1-25/32
[45.30]
2-9/16 [65.00]
Caution!
High Temperature
861HSSRXXX-XX-X
INPUT: (VOLTAGE)
INPUT
24-280 VAC
OUTPUT
10A
(VOLTAGE)
861HSSRXXX-XX-X
CERTIFIED FOR
CLASS 1
DIVISION 2
HAZARDOUS
LOCATIONS
GROUPS 1, B, C, & D
Patent Pending
#14 AWG COPPER WIRE MAXIMUM
RATED AT 75°C
7.1 lb-in TORQUE MAXIMUM
DIN RAIL
Derating
Derating
Series
861H
Hazardous Rated Solid State Relays
15 Amp Rating, SPST-NO, Internal Heat Sink
The Series 861H Hazardous Rated Solid State Relay provides reliable switching
and long life operation in some of the most demanding applications, such as medical
equipment, mining, oil and gas. It integrates an internal heat sink and internal snubber
into a compact housing to save space in the panel. In order to reduce installation time,
integral tabs can be used to snap the relay onto a DIN rail or surface mount to a wall inside
the panel. LED indicator lights give the user quick visual indication of the switch status.
The 861H is intrinsically safe rated for Class 1, Division 2 Groups A, B, C and D.
Model
861HSSR210-AC-1
861HSSR210-DC-1
861HSSR115-DD
Input Voltage
90 to 280 VAC
3 to 32 VDC
3.5 to 32 VDC
Load Voltage
24 to 280 VAC
24 to 280 VAC
3 to 50 VDC
Rated Current
10 amp
10 amp
15 amp
SPECIFICATIONS
Electrical Connection: Screw terminals.
Switching Operation: SPST normally open.
Switching Type: AC/DC: Zero cross; DD: DC switching.
Temperature Limits:
Storage: -40 to 212°F (-40 to 100°C);
Operation: -22 to 176°F (-30 to 80°C).
Voltage Loss: AC/DC: 1.6 VAC max; DD: 0.5 VDC max.
Output Leakage Current: AC/DC: 10 mA max; DD: 0.25 mA max.
Housing: Polycarbonate.
Hazardous Classification: Class 1 Division 2; Hazardous Locations: Groups A, B,
C and D.
Weight: 4.1 oz (127.1 g).
Agency Approvals: RoHS, cUR, UR.