Dwyer Instruments SERIES 636D Catalog Page

#22
G
[44.45]
SERIES 636D
PRESSURE
FIXED RANGE DIFFERENTIAL PRESSURE TRANSMITTER
AWG SHIELDED CABLE
Explosion-Proof, 0.5% Accuracy
Series 636D Fixed Range Differential Pressure Transmitter can be used for measuring pressures of liquids, gases & vapors. All available ranges have an excellent
0.5% FS accuracy with a 4-20 mA Output standard or optional 1-5 VDC output. The NEMA 4 housing is an all 316 welded construction that is designed to withstand the
harshest environmental conditions. With all 316L wetted materials, this transmitter is compatible with most media. These units are CSA approved explosion-proof for use in
the specied hazardous locations and meet NACE standards for off-shore applications.
FEATURES/BENEFITS
• NEMA 4X rated enclosure provides protection in harsh environments permitting
outdoor monitoring or in areas where dust and particulate matter exists
• Explosion-proof device for use in hazardous areas
• Versatile, high-accuracy device for liquid or gas supports designs requiring more precise measurements in support of application
APPLICATIONS
• Pump differential pressure
MODEL CHART Model
4 to 20 mA Out Range 636D-0
636D-1 636D-2 636D-3 636D-4 636D-5 636D-6 636D-7 636D-8
0 to 6 psid 0 to 15 psid 0 to 30 psid 0 to 60 psid 0 to 100 psid 0 to 150 psid 0 to 200 psid 0 to 300 psid 0 to 500 psid
• Critical process monitoring • Off shore applications
Model 1 to 5 VDC Out Range
636D-0-LP 636D-1-LP 636D-2-LP 636D-3-LP 636D-4-LP 636D-5-LP 636D-6-LP 636D-7-LP 636D-8-LP
0 to 6 psid 0 to 15 psid 0 to 30 psid 0 to 60 psid 0 to 100 psid 0 to 150 psid 0 to 200 psid 0 to 300 psid 0 to 500 psid
SPECIFICATIONS Service: Compatible gases, liquids, or
vapors.
Wetted Materials: Types 316L SS. Accuracy: BFSL: ±0.5% FS (includes linearity, hysteresis, and repeatability). Stability: ±1.0 FS/yr. Pressure Limits: 3 x FS differential
pressure; Burst: 2500 psig. Temperature Limits: Ambient operating:
-40 to 140°F (-40 to 60°C); Process interface: -40 to 212°F (-40 to 100°C); Storage: -40 to 212°F (-40 to 100°C). Compensated Temperature Range: -20 to 160°F (-29 to 71°C). Thermal Effect: ±2% FS/50°F (reference to 77°F). Power Requirements: 12-30 VDC for 4-20 mA outputs; 8-14 VDC for 1-5 VDC outputs, both with reverse polarity protection.
Output Signal: 4-20 mA DC or 1-5 VDC.
OPTIONS Use order code: Description NISTCAL-PT1 NIST traceable calibration certicate
24 INCHES LONG
1/2-14 NPT
FEMALE
CONNECTION
4-5/32 [105.4]
1-1/8 [28.5]
4-1/8 [104.7]
3/4-14 NPT FEMALE CONDUIT THREAD
1-1/4 HEX
1˝ HEX TYPICAL
Zero and Span Adjustment: Fixed. Response Time: 20 ms. Loop Resistance: 900 Ω max @ 30
VDC for current outputs. For voltage outputs, minimum lead resistance 50k ohms. Current Consumption: 4-20 mA for current output models; 3 mA for voltage output models. Electrical Connections: 2 ft, 22 AWG
cable; 3/4˝ female NPT conduit. Process Connections: Two 1/2˝ female NPT.
Enclosure Rating: NEMA 4 (IP56). Mounting Orientation: ±0.05 psi/90°
rotation from horizontal.
Weight: 1.8 lb (0.82 kg). Agency Approvals: CSA approved
explosion-proof for Class I, Division 1, Groups B, C, and D; Class II, Groups E, F, and G; Class III.
Ø1-3/4 [44.45]
1-3/4
SS TA
1-5/16 [33.02]
Differential Pressure Transmitters,
Loading...