Dwyer Instruments SERIES 43000 Catalog Page

[4] 6-32 HOLES
MOUNTING RING
SERIES 43000
CAPSU-PHOTOHELIC® PRESSURE SWITCH/GAGES
Lo-Limit and Hi-Limit Control, Aluminum or Brass Case Available
Set points are instantly adjusted with front knobs.
PRESSURE
3-1/16 [77.79] TYP
Ø4-3/4
[120.65]
Series 43000
®
Capsu-Photohelic
Series 43000
Capsu-Photohelic
Series 43000 Capsu-Photohelic® Pressure Switch/Gages function as versatile,
FEATURES/BENEFITS
• Gage capsule permits high-pressure usage with small differentials
• Zero and range adjustments outside of gage means no disassembly in normal service
• Time-proven, simple, frictionless movement that permits full-scale readings as low as 0.5 in w.c.
• Photo-electronic relays provide fast-acting switching with variable deadband control for chatter-free operation
APPLICATIONS
• Pump control
• Pumping systems
• Wastewater
• Compatible liquid or gas applications
®
switch/gage
switch/gage with brass body
®
gage design. The Capsu-Photohelic® switch/
3-7/8 SQ
[98.43]
3/4 CONDUIT
CONNECTION
4-3/8 [111.13]
HOUSING REMOVAL
3-7/8 [98.43]
5-1/8 [130.18]
EQUALLY SPACED ON A
5-1/8 [130.18] B.C.
1/4 FEMALE NPT
LOW PRESSURE
CONNECTION
[AIR OR GAS]
Ø5
[127.00]
Ø4-47/64
[120.25]
5/8 [15.88]
7-5/16 [185.74]
8-9/16 [217.49]
SPECIFICATIONS GAGE SPECIFICATIONS
Service: Compatible gases and liquids. Brass case option required for water based
liquids.
Wetted Materials: Consult factory. Accuracy: ±3% of FS at 70°F (21.1°C). ±4% on 43215, 43220 and 43500. Pressure Limits: -20 Hg to 500 psig (-0.677 to 34.5 bar). Temperature Limits: 20 to 120°F (-6.67 to 48.9°C). Low temperature option
available.
Process Connections: 1/4˝ female NPT. Size: 4˝ (101.6 mm) dial face, 5˝ (127 mm) OD x 9-3/16˝ (233.36 mm). Weight: 5 lb, 8 oz (2.49 kg). Brass 11 lb, 2 oz (5.05 kg).
SWITCH SPECIFICATIONS Switch Type: Each set point has 2 form C relays (DPDT). Repeatability: ±1% of FS. Electrical Rating: 10 A @ 120 VAC, 6 A @ 240 VAC, 60 Hz res. 10 A @ 28 VDC. Electrical Connections: Screw terminals. Power Requirements: 120 VAC, 50/60 Hz; 240 VAC and 24 VAC power optional. Mounting Orientation: Diaphragm in vertical position. Consult factory for other
position orientations. Set Point Adjustment: Adjustable knobs on face.
PANEL MAX
3/16 [4.76]
5/8 [15.88]
1/4 FEMALE
NPT LOW
PRESSURE
CONNECTION
[LIQUID]
1/4 FEMALE NPT HIGH PRESSURE CONNECTION [AIR OR GAS]
Ø [101.60]
FACE
5-1/2 [139.70] O.D.
1/4 FEMALE NPT HIGH PRESSURE CONNECTION [LIQUID]
3/4 [19.05] TYP
Gages/Switches, Dial
Differential Pressure
MODEL CHART Model Range in w.c. Model Range in w.c. 43000-0
0-.5
43001
0-1.0
43002
0-2.0
43003
0-3.0
43004
0-4.0
43005
0-5.0
43006
0-6.0
43008
0-8.0
43010
0-10
43015
0-15
43020
0-20
43025
0-25
43030
0-30
43040
0-40
ACCESSORIES Model Description A-298 Flat aluminum bracket for ush mounting
43050 43060 43080 43100 43150 43200 43300 43400 43500 43302 43304 43310 43320 43330
0-50 0-60 0-80 0-100 0-150 0-200 0-300 0-400 0-500 1-0-1 2-0-2 5-0-5 10-0-10 15-0-15
OPTIONS To order
add sufx: Description
-SRH
-SRL
-24VAC
-240VAC
-RMR
-TAMP
-WP
-EXPL
-NIST
Example: 43001-NIST
B Brass body; For water based liquids order optional brass case
Example: 43001B
Note: Contact Customer Service for detailed dimension drawings.
USA: California Proposition 65 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Single relay activates on increase Single relay activates on decrease 24 VAC relay pack 240 VAC relay pack Remote mounted relay Tamper proof knobs
Weatherproof (NEMA 4) Explosion-proof (NEMA 7 C, D, 9 E, F, G; NEC Class I, Div. 1 and 2,
Groups C, D, Class II, Div. 1 and 2, Groups E, F, G, Class III
NIST traceable calibration certicate
Process Tubing Options: See page 453 (Gage Tubing Accessories)
DWYER INSTRUMENTS, INC.
41