Dwyer Instruments SERIES 3100 Catalog Page

UNF FOR MOUNTING
[54.00]
3-25/64
®
E
SERIES 3100 | MERCOID® BY DWYER
EXPLOSION-PROOF DIFFERENTIAL PRESSURE TRANSMITTER
HART®, Push-Button Conguration, Rangeability (100:1)
PRESSURE
E
O
D
I
V
O
N
L
I
N
3100D
Mercoid® Series 3100 Explosion-Proof Smart Pressure Transmitter is
a microprocessor-based high performance transmitter, which has exible pressure calibration, push-button conguration, and programmable using HART® Communication. The Series 3100 is capable of being congured for differential pressure or level applications with the zero and span buttons. A eld calibrator is not required for conguration. The transmitter software compensates for thermal effects, improving performance. EEPROM stores conguration settings and stores sensor correction coefcients in the event of shutdowns or power loss. The Series 3100 is FM or ATEX approved for use in hazardous (classied) locations. The 100:1 rangeability allows the smart transmitter to be congured to t any
application.
FEATURES/BENEFITS
• Congurable using zero/span buttons means no calibrator required reducing time to
install and running
• Range-ability and selectable engineering units, allows transmitter to t many applications reducing the number of different transmitters to meet specications
• High accuracy (±0.075%) provides exceptional measurement for ensuring tight­ control and minimizing costly out of specication conditions
• Automatic sensor temperature compensation improves performance of device for accurate measurement under different operating environments
• Fail-mode process function stores conguration settings in the event of shutdown or
power-loss provides for faster restart to getting application back on-line
• A HART® Communication programmable device provides a reliable, long-term
solution for plant operators who seek the benets of intelligent devices with digital
communication
APPLICATIONS
Differential Pressure Transmitters
• Flow measurement
• Level monitoring
• Filter or pump differential pressure
• Critical process monitoring
7-37/64 [192.50]
4-13/32 [112.00]
2X DRAIN VALV E
1/4˝ NPT
PROCESS
CONNECTION
[86.00]
2-1/8
1-21/32
[42.00]
4X 7/16-20
3100D
SPECIFICATIONS Service: Compatible gases, steam, liquids or vapors.
Wetted Materials: 316L SS, uoroelastomer. Accuracy: ±0.075% FS (@ 20°C). Rangeability: 100:1 turn down. Stability: ±0.125% FSO/yr. Temperature Limits: Process: -40 to 248°F (-40 to 120°C); Ambient: Without
LCD: -40 to 185°F (-40 to 85°C); With LCD: -22 to 176°F (-30 to 80°C). Pressure Limits: Max pressure: Range: -14.5 to 2000 psi; Burst pressure: 10000
psi.
Thermal Effect: ±0.125% span/32°C. Power Requirements: 11.9-45 VDC. Output Signal: 4-20 mA / HART Response Time: 0.12 s. Damping Time: 0.25 to 60 s. Loop Resistance: Operation: 0 to 1500 Ω; HART® Communication: 250 to 500 Ω. Electrical Connection: Two 1/2˝ female NPT conduit, screw terminal. Process Connection: 1/4˝ female NPT. Display: Optional 5 digit LCD. Enclosure Rating: NEMA 4X (IP66) and explosion-proof for Class I, Div I, Groups
A, B, C and D.
Weight: 8.6 lb (3.9 kg). Agency Approvals: CE, FM, ATEX option available (consult factory).
®
Communication.
MODEL CHART Model Calibrated Span (Min. to Max.) Lower Range Limit Upper Range Limit LCD Display 3100D-2-FM-1-1
3100D-3-FM-1-1 3100D-4-FM-1-1 3100D-5-FM-1-1 3100D-6-FM-1-1 3100D-2-FM-1-1-LCD 3100D-3-FM-1-1-LCD 3100D-4-FM-1-1-LCD 3100D-5-FM-1-1-LCD 3100D-6-FM-1-1-LCD
0.6 to 30 in w.c.
1.5 to 150 in w.c.
7.5 to 750 in w.c. 1 to 100 psi 3 to 300 psi
0.6 to 30 in w.c.
1.5 to 150 in w.c.
7.5 to 750 in w.c. 1 to 100 psi 3 to 300 psi
0.15 to 7.5 kPa
0.373 to 37.3 kPa
1.865 to 186.5 kPa
6.9 to 690 kPa
20.68 to 2068 kPa
0.15 to 7.5 kPa
0.373 to 37.3 kPa
1.865 to 186.5 kPa
6.9 to 690 kPa
20.68 to 2068 kPa
-30 in w.c.
-150 in w.c.
-750 in w.c.
-100 psi
-300 psi
-30 in w.c.
-150 in w.c.
-750 in w.c.
-100 psi
-300 psi
-7.5 kPa
-37.3 kPa
-186.5 kPa
-690 kPa
-2068 kPa
-7.5 kPa
-37.3 kPa
-186.5 kPa
-690 kPa
-2068 kPa
30 in w.c. 150 in w.c. 750 in w.c. 100 psi 300 psi 30 in w.c. 150 in w.c. 750 in w.c. 100 psi 300 psi
7.5 kPa
37.3 kPa
186.5 kPa 690 kPa 2068 kPa
7.5 kPa
37.3 kPa
186.5 kPa 690 kPa 2068 kPa
No No No No No Yes Yes Yes Yes Yes
Note: Consult factory for custom calibration.
DWYER INSTRUMENTS, INC. | 70
HART® is a registered trademark of Hart Communication Foundation
®
SERIES 3100 | MERCOID® BY DWYER
EXPLOSION-PROOF DIFFERENTIAL PRESSURE TRANSMITTER
HART®, Push-Button Conguration, Rangeability (100:1)
MODEL CHART Example 3100D -2 -FM -3 -1 -LEC S2 A1 05 S 2 -05 -10 -LCD 3100D-2-FM-3-1-LECS2A105S2-05-10-LCD Series 3100D Explosion-proof differential pressure transmitter Range 1
Approval FM
Process Connection 1
Electrical Connection 1 1/2˝ female NPT Diaphragm Seal Type LEC
Mounting Flange S2
Mounting Flange Rating A1
Extension Length 00
Diaphragm Material S
Fill Fluid 2 Silicon oil (-40 to 400°F) Capillary Length High Side XX 0 to 20 feet Capillary Length Low Side XX 0 to 20 feet Options LCD
2 3 4 5 6 7
ATEX WP
3
LED LEH LEL LFC LFD LFH LFL
S3
A2 D1 D2 J1 J2
05 10 15
P H T
0 to 6 in w.c. 0 to 30 in w.c. 0 to 150 in w.c. 0 to 750 in w.c. 0 to 100 psi 0 to 300 psi 0 to 1000 psi
FM approved ATEX approved Weatherproof only (only available with 316 SS housing)
1/4˝ female NPT
Diaphragm seal
2 extended diaphragm seals capillary type 1 extended diaphragm seal direct mount high side 1 extended diaphragm seal capillary type high side 1 extended diaphragm seal capillary type low side
2 ush diaphragm seals capillary type 1 ush diaphragm seal direct mount high side 1 ush diaphragm seal capillary type high side 1 ush diaphragm seal capillary type low side
2˝ (50 mm) 316L SS 3˝ (80 mm) 316L SS
ANSI class 150# ANSI class 300# DIN PN 10/16 DIN PN 25/40 JIS 10 K JIS 20 K
No extension [standard for ush mount] 2˝ extension 4˝ extension 6˝ extension
316L SS diaphragm PTFE and 316L SS diaphragm Hastelloy C-276 diaphragm Tantallum diaphragm
5 digit LCD
SSH
316 SS housing (Only available with WP approval)
NIST
NIST calibration
CC
Custom calibration
PRESSURE
Differential Pressure Transmitters
CUSTOM CALIBRATION VALUES Primary Units
Upper Range Limit Lower Range Limit Output Damping Time Display Mode Display Units Engineering Units*
Engr. Upper Range Limit* Engr. Lower Range Limit* Engr Function*
*Engineering Units, Engr. Upper Range Limit, Engr. Lower Range Limit and Engr. Function values are only required if engineering unit is selected.
ACCESSORIES Model Description A-630
A-631 BBV-1F BBV-22F DevCom2000
Stainless steel angle type bracket with SS bolts
Stainless steel at type bracket with SS bolts
Flanged 3-valve block manifold Flanged 5-valve block manifold
®
HART
in w.c., ft in w.c., mm in w.c., in Hg, psig, g/cm 20 mA value 4 mA value Linear or square root 0 to 60 seconds Unit, %, mA, rotate Primary unit or Engineering unit Volumetric Flow Units US gal/s, US gpm, US gal/hr, US gpd, imp gal/s, imp gpm, imp gal/hr, imp gpd, l/s, l/min, l/hour, ft/s, m/s, metric gal/day, metric l/day, ft3/s, ft3/min, ft3/h, ft3/day, m3/s, m3/min, m3/hr, m3/day, normal l/hr, normal m3/hr, standard ft3/min, barrels/s, barrels/min, barrels/hr, barrels/day
Mass Flow Units
g/s, g/min, g/hr, kg/s, kg/min, kg/hr, kg/day, metric ton/min, metric ton/hour, metric ton/day, lb/s, lb/min, lb/hr, lb/day, short ton/min, short ton/ hr, short ton/day, long ton/hr, long ton/day Volume Units gallons, liters, imp gallons, m3, barrels, bushels, yd3, ft3, in3, bbl liq, normal cubic meter, normal liter, standard cubic feet, hectoliters Engr. upper value Engr. lower value Linear or square root
Communication Protocol Software
2
, kg/cm2, MPa, Pa, kPa, bar, mbar, Torr, Atm, mm Hg
HART® is a registered trademark of Hart Communication Foundation
DWYER INSTRUMENTS, INC. |