Dwyer Instruments SERIES 200, SERIES 300 Catalog Page

Ø1/2 [12.70]
[47.63]
[14.29]
MOUNTING
SERIES 200 & 300
DURABLOCK® SOLID PLASTIC STATIONARY GAGES
Suitable for Total Pressures Up to 100 psig, Temperatures Up to 150°F, Accuracy ±2% of Full-Scale (1% on Models 215, 244, 246 Only)
Manometers, Stationary
G
Ø1/2
[12.70]
HOLES
TYP 6
PLACES
1
[25.40] TYP
®
Series 200 & 300 Durablock® Solid Plastic Stationary Gages, or draft gages,
Dwyer
are offered in inclined and vertical (well-type) styles for highly accurate laboratory or general industrial service, for measurement of low range gas and air pressures, positive, negative or differential. To assure the accuracy required in instruments of this type, all machining of bores and wells is to the highest standards of precision backed by Dwyer’s years of experience in the fabrications of acrylic instruments.
FEATURES/BENEFITS
• High-accuracy measurement of low range gas and air pressure suitable for laboratory or general industry
• Precision built assures device meets the highest standards
• No moving parts mean no calibration or nothing to wear out
• Over-pressure trap prevents liquid from being expelled from gage, preventing disruption of operation
APPLICATIONS
• Low pressure laboratory and industrial service applications
Exclusive Dwyer® over-pressure safety traps assure that over range pressures whether gradual or a sudden surge will not force the liquid out of the gage. Over-pressures simply raise the oat, force the O-ring over the opening and seal the uid in the gage. When pressure is reduced, the oat drops down releasing the O-ring safety trap which allows the gage to continue operation.
[76.20]
Model 310
F TYP
B
E TYP
E TYP
3
A
1/2
[12.70]
TYP
1-7/8
[47.63]
9/16
[14.29]
MOUNTING HOLES
TYP 6 PLACES
D
E
TYPFTYPFTYP
B
Dimensions, Inches
Model
1/2 [12.70] TYP
1 [25.40] TYP
C
A
9/16
1-7/8
Model 200.5
MODEL CHART Incline Type
Model
200.5
202.5 209 215 244 246
Vertical or Well-Type Model
310 0-10 .10 11-1/8 3-10 Note: Model 200.5 replaces Model 200. Model 202.5 replaces Model 202.
OPTIONS To order add sufx: Description
-NIST NIST traceable calibration certicate
Example: 244-NIST
Range Inches of Water
.10-0-1.0 .20-0-2.0 .20-0-3.0 .05-0-.25 0-4 0-6
Range Inches of Water
A B C D E F G
200.5
7
13
3-15/16
202.5 209 215 244 246 310
9 9 7 11
13-1/2
7
Minor Scale Divisions
.01 .01 .02 .005 .02 .02
Minor Scale Divisions
13 13 10 16-1/2 23
16
5-5/8
7
3-1/16 3-1/8
11
-
Scale Length
8-1/4 8-3/4 8-3/4
6
13-1/4 20
Scale Length
11-3/8 12 11-1/4 9-1/2 15-5/8 22
-
Weight lb-oz
3-11 4-7 4-11 2-14 9-11 13-14
Weight lb-oz
2
4-1/2 4-1/2 4-1/2 3 8-1/2 15
4
-
-
-
-
-
­15-1/4
2 2 2
4 4 4
29