Dwyer Instruments MTL5041 Data sheet

PROCESS CONTROL
41/64
[16.27]
HAZARDOUS
AREA TERMINAL
SAFE AREA TERMINAL
4-3/32
[103.98]
4-11/32
[110.33]
Barriers
Intrinsically Safe
MTL5041/
5045
MTL5041
Galvanic Barrier
Intrinsically Safe Isolators for Hazardous Locations
The MTL5041/5045 Galvanic Barrier provide total intrinsically safe isolation for communication with Dwyer®pressure transmitters approved for location in hazardous areas. Galvanic barrier eliminates the need for a high integrity earth ground required when using shunt diode type safety barriers. DIN rail mounting and plug-in signal and power connectors simplify installation and maintenance
Compatible Models:  637, 638, 608, 2700, 2800, 2900,
392
Galvanic Barrier MTL5041
MTL5041
MTL5041
MTL5041
MTL5045
MTL5045
MTL5041/5045
Region (Authority)
USA (FM) (UL)
Canada (CSA)
UK (BASEEFA) UK (BASEEFA) Systems
Approval
FM for Class I, II, II; Div. 1 Groups C, D, F, G UL for Class I; Div. 1 Groups A, B, C, D Class II Div. 1 Groups E, F, G Class III Div 1
FM for Class I, II, III; Div. 1 Groups B, C, D, E, F, G FM for Class I, II, III; Div. 1 Groups A, B, C, D, E, F, G FM for Class I, II, III; Div. 1 Groups C, D, E, F, G FM for Class I, II, III; Div. 1 Groups C, D, E, F, G
Group A & B C D
Group IIC IIB IIA
FM
µF
0.13
0.30
1.04
BASEEFA (ATEX)
µF
mH
0.083
3.05
0.85
9.15
2.15
244
DWYER INSTRUMENTS, INC. | www.dwyer-inst.com
SBLTX, PBLTX, IS626
mH
4.2
12.6
33.6
µH/Ω 55 210 444
Standard
3600, 3610 entity 3611, 3810 UL913 UL1604
CAN/CSA E60070, IEC60079, C22.2
EN 50014, EN 50020 EN 50039
Dwyer Series
638
IS626, SBLTX, PBLTX 637
608
2900
2700/2800
Approved For
AIS/I,II,III/1/Entity ABCDEFG­SCI-942; NI/I/@/ABCD/T4 [I/0] AEx[ia]IIC-SCI-942 Entity; NI/1/2/IIC/T4; Ta=140°F (60°C) Class I, Div.2, Gps A, B, C, D; Ex nA [iA] IIC T4 Class I, Xone 2, Aex nA IIC T4 EEx ia IIC EEx ia IIC
SPECIFICATIONS Hazardous Area Input:
Signal range: 0 to 24 mA (including over-range); Transmitter voltage: 16.5 V at 20 mA.
Safe Area Output: 
Signal range: 4 to 20 mA; Safe-area load resistance: 0 to 1kΩ; Safe-area output resistance: > 2 MΩ.
Power Requirement: 20 to 35 VDC. Response Time: Settles to within 10% of final value within 250 µs. Current Consumption (20 mA signal):
70 mA at 24 VDC; 85 mA at 20 VDC; 55 mA at 35 VDC.
Maximum Power Dissipation (20 mA signal): 1.2 W at 24 VDC. Isolation: 250 V rms between input, output and power supply terminals. Transfer Accuracy at 68°F (20°C): Better than 20 µA (typically 5 µA). LED Indicator: Green: Power indication. Temperature Limits: Operating: -4 to 140°F (-20 to 60°C); Storage: -40
to 176°F (-40 to 80°C).
Temperature Drift: <1 µA/°C. Humidity: 5 to 95% RH. Mounting: 1.4˝ (35 mm) top hat rail to:
EN 50022-35 x 7.5; BS 5584; 35 x 27 x 7.3 DIN 46277.
Terminals: Accommodate up to 2.5 mm Safety Description: 28 V, 300Ω, 93 mA; Um=250 rms or dc. Weight: 3.9 oz (110 g). Agency Approvals: See table below.
Certificate/file no.
3010737
1345550
BAS01ATEX7217 Ex01E2219
ACCESSORY A-360, Aluminum DIN Rail 1 m
2
stranded or single-core.
Loading...