Dwyer Instruments IS626 Specifications

1/4 NPT
1-1/16 [26.00] HEX
ø1 [25.40]1-1/16 [26.99] HEX
1/4 NPT
ø1 [25.40]
®
E
SERIES IS626
INTRINSICALLY SAFE PRESSURE TRANSMITTER
For Use In Hazardous Locations
PRESSURE
OR
1/4 BSPT
1-1/16 [26.99] HEX
ø1 [25.40]
5-1/16 [128.58]
5-21/32 [143.67]
Male NPT/BSPT Connector with Male M-12 Connector Male NPT/BSPT Connector with Cable Gland
OR
1/4 BSPT
FEMALE
E
O
D
I
V
O
N
L
I
N
5-1/16 [128.58]
5-21/32 [143.67]
Female NPT/BSPT Connector with Male M-12 Connector Female NPT/BSPT Connector with Cable Gland
The Dwyer SERIES IS626 Intrinsically Safe Pressure Transmitter can be used to accurately measure compatible gases and liquids compatible with its 316/316L stainless steel wetted parts. Series IS626 full-scale accuracy is 0.25%. Designed for industrial environments with a NEMA 4X (IP66) housing, this transmitter resists most effects of shock and vibration. Models are available with a 3´ cable or M-12 4 pin connection.
The IS626 is UL listed for use in Hazardous (Classied) Locations. The protection
method is by Intrinsic Safety, “ia”. It was investigated by UL under UL Standard 913 Sixth Edition and CSA Standard No. 157-92.
FEATURES/BENEFITS
• Exceptional accuracy for insuring tight-control and minimizing costly out of
specication conditions
• NEMA 4x rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists
• Robust sensor provides shock and vibration resistance insuring stability in controlling
Single Pressure Transmitters
pressure for process applications
APPLICATIONS
• Monitoring pressure in hazardous environments
• Process
1/4 NPT OR 1/4 BSPT
1-1/16 [26.99] HEX
5-3/16 [131.75]
6-1/4 [158.75] MAX
1/4 NPT OR
1/4 BSPT
FEMALE
5-3/16 [131.76]
5-1/4 [158.75]
SPECIFICATIONS Service: Compatible gases and liquids. Wetted Materials: Type 316, 316L SS. Accuracy: 0.25% FS; Absolute range:
0.5% FS (includes linearity, hysteresis, and repeatability). Temperature Limit: 0 to 176°F (-18 to 80°C).
Compensated Temperature Range:
0 to 176°F (-18 to 80°C). Thermal Effect: ±0.02% FS/°F (includes zero and span). Pressure Limits: See Pressure Range Table.
Power Requirements: 10 to 28 VDC. Output Signal: 4 to 20 mA. Response Time: 50 ms. Loop Resistance: 0 - 900 Ω max. Current Consumption: 38 mA (max). Electrical Connections: 3 ft cable or
4-pin M-12 connector.
Process Connection: 1/4˝ male or
female NPT and BSPT.
ø1 [25.40]
Enclosure Rating: NEMA 4X (IP66). Mounting Orientation: Mount in any
position.
Weight: 8.9 oz (252 g). Agency Approvals: CE, cULus
Intrinsically Safe to UL Standard 913.
For use in Hazardous (Classied)
Locations: Class I Div. 1 Groups A,B,C,D Class II Div. 1 Groups E,F,G Class III Div. 1 Temperature Code: T4 @ 80°C ambient Install in accordance with control drawing 01-700797-00. WARNING To prevent ignition
of ammable or combustible
atmospheres, disconnect power before servicing. Use with approved safety barriers using entity evaluation.
MODEL CHART
Model Range IS626-00-GH-P1-E1-S1 IS626-07-GH-P1-E1-S1 IS626-08-GH-P1-E1-S1 IS626-09-GH-P1-E1-S1 IS626-10-GH-P1-E1-S1 IS626-11-GH-P1-E1-S1 IS626-12-GH-P1-E1-S1 IS626-13-GH-P1-E1-S1 IS626-14-GH-P1-E1-S1 IS626-15-GH-P1-E1-S1 IS626-16-GH-P1-E1-S1
15 psia* 15 psig 30 psig 50 psig 100 psig 150 psig 200 psig 300 psig 500 psig 1000 psig 1500 psig
Maximum
Pressure (psig)
30 30 60 100 200 300 400 600 1000 2000 3000
Over Pressure
(psig)
150 150 300 300 500 750 1000 1500 2500 5000 5000
*Absolute pressure ranges are not UL approved.
Note: For optional M-12 4 pin electrical connection, change E1 to E6.