Dwyer Instruments DW-WIFI Specifications

SERIES DW-WIFI
WIRELESS WI-FI DATA LOGGER
Measures Temperature/Humidity, Integral LCD
Data Loggers, Wireless
The SERIES DW-WIFI Wireless Wi-Fi Data Logger measures and records up to
1,000,000 temperature and/or humidity readings and shares the data with any PC or server on the same Wi-Fi network. If the Wi-Fi connection is lost, the sensor will continue to store any records until it can regain communication with the network. The
downloadable Windows
rate, and the temperature scale.
FEATURES/BENEFITS
• Continues to record values even if Wi-Fi connection is lost
• Able to record up to 1,000,000 data points, which can be downloaded to a PC
• Large LCD allows users to view data directly from unit
APPLICATIONS
• Building/site monitoring
• Environment monitoring
• Weather monitoring
MODEL CHART
Model Input Range Accuracy (Typ.) DW-WIFI-T
DW-WIFI-TH
DW-WIFI-TP DW-WIFI-TC DW-WIFI-T-HA DW-WIFI-TH-HA
DW-WIFI-TP-HA
*Probe dependent
®
based software allows users to set high/low alarms, sampling
Internal temperature Internal temperature/humidity
Remote temperature probe Remote thermocouple Internal temperature Internal temperature/humidity
Remote temperature probe
-4 to 140°F (-20 to 60°C)
-4 to 140°F (-20 to 60°C), 0 to 100% RH
-40 to 257°F (-40 to 125°C)
-454 to 2372°F (-270 to 1300°C)*
-4 to 140°F (-20 to 60°C)
-4 to 140°F (-20 to 60°C), 0 to 100% RH
-40 to 257°F (-40 to 125°C)
3-7/8
[97.30]
SPECIFICATIONS Memory Size: 1,000,000 readings; 500,000 each for DW-WIFI-TH(-HA).
Sampling Mode: Continuous recording. Sampling Rate: Selectable from 10 s to 12 hr. Transmission Rate: Selectable from 1 min to 24 hr. Temperature Limits: -4 to 140°F (-20 to 60°C). Power Requirements: 3.7 V lithium ion battery, installed functional, factory
replaceable (cable for charging included).
Alarms: Programmable high/low. Interface: Wi-Fi connection. Probe Length: DW-WIFI-TP: 11.8˝ (30 cm); DW-WIFI-TC: 59˝ (150 cm). Weight: 7.2 oz (204 g).
±1.0°F (±0.5°C) @ 14 to 122°F (-10 to 50°C) ±0.6°F (±0.3°C) @ 41 to 140°F (5 to 60°C) ±2.5% RH @ 20 to 80% RH ±1.2°F (±0.6°C) @ 14 to 158°F (-10 to 70°C) ±3.0°F (1.5°C) ±0.2°F (±0.1°C) @ 14 to 140°F (-10 to 60°C) ±0.4°F (±0.2°C) @ 41 to 140°F (5 to 60°C) ±2.5% RH @ 10 to 90% RH ±0.2°F (±0.1°C) @ 14 to 158°F (-10 to 70°C)
1
[26.36]
Display Resolution
0.1°F (0.1°C)
0.5°F (0.5°C)
1.0% RH
0.1°F (0.1°C)
0.1°F (0.1°C)
0.1°F (0.01°C)