Series BPI/TC Battery Powered Digital Thermometer
Specifications - Installation and Operating Instructions
The Series BPI is a range of battery powered temperature
indicators. The Series BPI-XX2 accepts a thermocouple sensor.
The sensor type, temperature units and other flexible
configuration settings are selectable via a simple to use menu
system, which is navigated by the use of three push-button keys
located on the rear of the display. The entire assembly is sealed
into a cap that fits directly onto the connecting heads.
Please inspect the packaging and instrument thoroughly for any
signs of transit damage. If the instrument has been damaged,
please notify your shipper immediately.
INSTALLATION
Configuration - Fit the battery as described in Battery section,
then follow the simple configuration menus printed on the
reverse side of this sheet. This procedure can be performed with
or without the sensor connected. Fit the correct units legend to
the front panel face.
Enclosure - The case offers various options for sensor entry.
Please refer to the data sheet for further details. The sensor
may be fixed directly to the housing, or remotely connected
using cable and gland. Cable length must be no greater than 20
meters to comply with CE certification. All external
cabling/sensor entries must maintain IP67 rating.
Wiring
BPI/TC Connection
SPECIFICATION @ 68°F (20°C)
Inputs: Thermocouple or RTD depending on model.
Accuracy: Thermocouple input: ±0.1% FS, ±0.5°C
(plus sensor); RTD: ±0.2°C ±0.1% of reading (plus sensor error).
Power Requirements: 3.6 V Lithium battery.
Battery Life: >2 years.
Display: 4-digit LCD.
Resolution: 0.1°C.
Ambient Operating Temperature: 14 to 158°F (-10 to 70°C).
Storage Temperature: -4 to 185°F (-20 to 85°C).
Weight: 6.0 oz (170 g).
Front Panel Protection: NEMA 4X (IP65).
Agency Approval: CE.
Sensor
K
J
T
N
R
S
E
F
-328 to 2498°F (-200 to 1370°C)
-148 to 2192°F (-100 to 1200°C)
-292 to 2372°F (-180 to 1300°C)
-328 to 1832°F (-200 to 1000°C)
Range °F (°C)
-346 to 752°F (-210 to 400°C)
14 to 3200°F (-10 to 1760°C)
14 to 3200°F (-10 to 1760°C)
-148 to 1112°F (-100 to 600°C)
Note: For type R, S and B sensors accuracy only applies
between 1472 and 3200°F (800 and 1760°C).
Battery
WARNING
Fire, Explosion and severe burn hazard, DO NOT
Recharge, Crush, Disassemble, Heat above
100°C (212°F), Incinerate or expose contents to water. NEVER
short circuit the battery. Disposal, the battery may be regulated
by national and local regulations. Please follow the instructions
of the proper regulator.
To install battery, first gain access to the battery by unscrewing
the cap retaining nut and removing cap from base. To remove
old battery, ease out the positive end of the battery from the
holder, using a screw driver blade. To fit battery, insert battery
negative into the spring contact end of the battery holder, then
press battery into place.
The units monitor their batteries. When the battery approaches
the end of its lifetime (over 2 years under normal conditions), the
display will toggle the message “LO BAT”.
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
MAINTENANCE
Apart from battery replacement this equipment requires no user
maintenance. If re-calibration is required please contact your
supplier for further information. Under certain circumstances, it
may be possible to re-calibrate the device while it is still out in
an application.
Please observe the battery warning. Ensure the instrument is
nstalled with adequate protection against the environment. IP67
i
rating must be maintained. Try to avoid installing the equipment
close to sources of extreme temperature and electrical or
electromagnetic interference. Any cleaning of the instrument
should be carried out using a mild detergent and a soft cloth. No
solvents or abrasive cleaner should be used.
SERIES BPI/TC CONFIGURATION MENU GUIDE
The Series BPI/TC Battery Powered Temperature Indicator is
not field serviceable and should be returned if repair is needed
(field repair should not be attempted and may void warranty). Be
sure to include a brief description of the problem plus any
relevant application notes. Contact customer service to receive
a return goods authorization number before shipping.
There are three buttons, which the operator must
press in various combinations in order to configure
the device. These buttons are located on the
underside of the indicator’s circuit board. Viewed
from the front, the three buttons (CYCle ,
INCrement and DECrement
) are shown in the diagram
to the left. Pressing 2 buttons
simultaneously causes ENTer
or ESCape actions.
When cycling around menu, the
title (e.g. TYPE, UNIT, etc.) is
displayed for a second, then the
menu entry is displayed ready for
editing. Then use INC/DEC to
move through entries in a list, or
to edit a real number
.
CYCle around menu
If no buttons are pressed for a minute or more, the
device assumes run-time mode. The display shows
the PV (if the input is in range) or shows or
to indicate over/under range. In order to access
menu configurationmode, the user must press
ENTer followed immediately by CYCle . In
order to exit the menu and return to run-time, a user
must press ESCape .
INCrement menu entry
DECrement menu entry
ENTer to confirm entry, or:
CYCle to next menu entry
ESCape
©Copyright 2011 Dwyer Instruments, Inc. Printed in U.S.A. 4/11 FR# R5-443914-10
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Phone: 219/879-8000 www.dwyer-inst.com