RS
232
DC
9V
MODE
ENTER
HOLD
REC
Mx/Mn
START
8912
BTUP
SYCHROMETER
6-45/64
[170.3]
2-49/64
[70.4]
2-13/32
[61.1]
1-1/8
[28.8]
1-19/64
[33.0]
3-1/64
[76.5]
Model
DATALOGGING
AIR FLOW / RH / TEMP. 9671
6-47/64
[171.0]
2-3/4
[70.0]
3-1/64
[76.5]
1-9/16
[39.5]
PS/2 PLUG
L
TELESCOPING
9671
Multi-Function Vane Thermo-Anemometer
Measures Air Velocity, Air Volume, Temperature, Humidity, and BTU; Built-In Datalogging
Measure air velocity, air volume, temperature, humidity, and BTU with the Model
9671 Multi-function Anemometer. The large 1.8˝ (45 mm) display allows users to easily view
readings. User-selectable wind speed units include f t/min, m/s, knots, mph and km/hr. In
addition to these f unctions, the 9671 is capable of measuring relative humidity, wet bulb
temperature, dew point and BTU capacity. A built-in sensor records ambient temperature in
°F or °C. Model 9671 features include data hold, along with the ability to record minimum,
maximum a nd average readings on a single point. Additi onal features incl ude an RS-2 32
inter face setting that allows the unit to download data, as well as upload up t o 99
measurements through pre-edited PC files. The 9671 also has a detachable probe for easy
replacement, if necessar y, or to attach a miniature vane probe. Each unit includes hard
carrying case, batteries, software CD, cable and instruction manual.
Model 9671, Vane Thermo-Anemometer
ACCESSORIES
A-551, Replacement Probe with Vane
A-VT-300P, Replacement Probe with Miniature Vane
CONTACT US | U.S. 219/879-8000 | U.K. (+44) (0)1494-461707 | A.U. (+61) (0) 2 4272 2055 | China +852-23181007
SPECIFICATIONS
AIR VELOCITY
Range: 118 to 6299 ft/min (0.6 to 32
m/s).
Accuracy: ±5% of reading or last
significant digit (whichever is greater).
Resolution: 0.1 ft/min (0.1 m/s).
Response Time: 1 second.
TEMPERATURE
Range: -4 to 140°F (-20 to 60°C).
Accuracy: ±1°F (±0.6°C).
Resolution: 0.1°F/°C.
Response Time: 60 seconds.
RELATIVE HUMIDITY
Range: 0 to 100%.
Accuracy: ±3% @ 25°C from 10 to
90% RH. Outside this range: ±5%.
Resolution: 0.10%.
Response Time: 60 seconds.
AIR VOLUME
Range: 0 to 99999 (CFM or m
Accuracy: ±5% of reading or last
3
/s).
significant digit (whichever is greater).
Resolution: 0.1 (0 to 9999.9) or 1
(10000 to 99999).
Response Time: 1 second.
WET BULB
Range: -7.6 to 158°F (-22 to 70°C).
Resolution: 0.1°F/°C.
METER
Display: 1 x 1.8˝ (26 x 45 mm).
Serial Communications: 9600 bps, 8
data bits, no parity.
Power Requirements: (4) AAA
alkaline batteries, included, user
replaceable.
Battery Life: 100 hours.
Vane Diameter: 3˝ (77 mm).
Weight: 6 oz (170 g).
Agency Approvals: CE.
419