Dwyer Instruments 9671 Data sheet

RS
232
DC
9V
MODE
ENTER
HOLD
REC
Mx/Mn
START
8912
BTUP
SYCHROMETER
6-45/64
[170.3]
2-49/64
[70.4]
2-13/32
[61.1]
1-1/8
[28.8]
1-19/64
[33.0]
3-1/64
[76.5]
Model
DATALOGGING
AIR FLOW / RH / TEMP. 9671
6-47/64
[171.0]
2-3/4
[70.0]
3-1/64
[76.5]
1-9/16
[39.5]
PS/2 PLUG
L
TELESCOPING
9671
Multi-Function Vane Thermo-Anemometer
Measures Air Velocity, Air Volume, Temperature, Humidity, and BTU; Built-In Datalogging
Measure air velocity, air volume, temperature, humidity, and BTU with the Model 9671 Multi-function Anemometer. The large 1.8˝ (45 mm) display allows users to easily view readings. User-selectable wind speed units include f t/min, m/s, knots, mph and km/hr. In addition to these f unctions, the 9671 is capable of measuring relative humidity, wet bulb temperature, dew point and BTU capacity. A built-in sensor records ambient temperature in °F or °C. Model 9671 features include data hold, along with the ability to record minimum, maximum a nd average readings on a single point. Additi onal features incl ude an RS-2 32 inter face setting that allows the unit to download data, as well as upload up t o 99 measurements through pre-edited PC files. The 9671 also has a detachable probe for easy replacement, if necessar y, or to attach a miniature vane probe. Each unit includes hard carrying case, batteries, software CD, cable and instruction manual.
Model 9671, Vane Thermo-Anemometer
ACCESSORIES A-551, Replacement Probe with Vane A-VT-300P, Replacement Probe with Miniature Vane
CONTACT US | U.S. 219/879-8000 | U.K. (+44) (0)1494-461707 | A.U. (+61) (0) 2 4272 2055 | China +852-23181007
SPECIFICATIONS AIR VELOCITY Range: 118 to 6299 ft/min (0.6 to 32
m/s). Accuracy: ±5% of reading or last significant digit (whichever is greater).
Resolution: 0.1 ft/min (0.1 m/s). Response Time: 1 second.
TEMPERATURE Range: -4 to 140°F (-20 to 60°C). Accuracy: ±1°F (±0.6°C). Resolution: 0.1°F/°C. Response Time: 60 seconds.
RELATIVE HUMIDITY Range: 0 to 100%. Accuracy: ±3% @ 25°C from 10 to
90% RH. Outside this range: ±5%.
Resolution: 0.10%. Response Time: 60 seconds.
AIR VOLUME Range: 0 to 99999 (CFM or m Accuracy: ±5% of reading or last
3
/s).
Response Time: 1 second.
WET BULB Range: -7.6 to 158°F (-22 to 70°C). Resolution: 0.1°F/°C.
METER Display: 1 x 1.8˝ (26 x 45 mm). Serial Communications: 9600 bps, 8
data bits, no parity. Power Requirements: (4) AAA alkaline batteries, included, user replaceable.
Battery Life: 100 hours. Vane Diameter: 3˝ (77 mm). Weight: 6 oz (170 g). Agency Approvals: CE.
419