Dwyer Instruments 629C series Specifications-installation And Operating Instructions

Series 629C Wet/Wet Differential Pressure Transmitter
L
®
Specications - Installation and Operating Instructions
5-15/16 [150.88]
1/4 NPT FEMALE FITTING
OPTIONAL 1/4 NPT MALE FITTING
7 [177.80]
Bulletin P-629C
43/64
[17.15]
1-11/32
[34.29]
3-7/64 [78.83]
1-31/32
1-27/64
[35.98]
[50.16]
OPTIONA
LCD
The SERIES 629C Wet/Wet Differential Pressure Transmitter monitors differential pressure of compatible gases and liquids with 0.5% accuracy. The design employs dual pressure sensors converting pressure changes into a 4 to 20 mA or voltage output signal. Small internal volume and minimal moving parts result in exceptional response and reliability. The wiring terminals and zero adjustment button are easily accessed under the removable cover. The Series 629C is designed to meet NEMA 4X (IP66) weatherproof construction.
RANGE Range Number Range Working Pressure* Over Pressure
01 02 03 04 05 06 07 08 09 11 12 13 14 15 16 17 18 19
*Pressures exceeding the working pressure limit may cause a calibration shift
of up to ±3% of full scale. Note: Over pressure of all models with 3-way valve is 100 psi.
0 to 5 psid 0 to 10 psid 0 to 25 psid 0 to 50 psid 0 to 100 psid 0 to 150 psid 0 to 200 psid 0 to 300 psid 0 to 500 psid 0 to 0.5 bar differential 0 to 1 bar differential 0 to 2 bar differential 0 to 4 bar differential 0 to 6 bar differential 0 to 10 bar differential 0 to 15 bar differential 0 to 20 bar differential 0 to 30 bar differential
Table 1: Pressure Limits
10 psi 20 psi 50 psi 100 psi 200 psi 300 psi 400 psi 600 psi 1000 psi 1 bar 2 bar 4 bar 8 bar 12 bar 20 bar 30 bar 40 bar 60 bar
50 psi 50 psi 120 psi 250 psi 500 psi 750 psi 1000 psi 1200 psi 2000 psi 3 bar 8 bar 8 bar 18 bar 18 bar 50 bar 60 bar 80 bar 120 bar
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Without valve: 316, 316L SS. Additional wetted parts with valve option: Buna-N, silicone grease, PTFE, brass 360, copper, and reinforced copolymer. Accuracy: ±0.5% FS (includes linearity, hysteresis & repeatability). Stability: ±1% FS/year. Temperature Limits: 0 to 200°F (-18 to 93°C). Compensated Temperature Limits: 0 to 175°F (-18 to 79°C).
Pressure Limits: See Table 1. Thermal Effects: Avg 0.04%/°F
(0.072%/°C) (includes zero and span). Power Requirements: 2-wire: 10 to 35 VDC; 3-wire: 13 to 35 VDC or isolated 16 to 33 VAC (reverse polarity protected). Output Signal: 2-wire: 4 to 20 mA; 3-wire: Field selectable 0 to 5, 1 to 5, 0 to 10, or 2 to 10 VDC.
Zero and Units: Push buttons inside conduit enclosure.
Response Time: 400 msec. Loop Resistance: Current output: 0
to 1250 Ω (max), Rmax = 50(Vps-10);
Voltage output: Minimum load resistance
= 5 kΩ.
Current Consumption: 28 mA (max). Electrical Connections: Removable
terminal block; 1/2˝ female NPT conduit. Process Connections: 1/4˝ female or
male NPT.
Display: Optional 4-1/2 digit LCD eld
attachable display. Enclosure Rating: Designed to meet NEMA 4X (IP66) for non-LCD models. Mounting Orientation: Not position sensitive.
Weight: 10.1 oz (286 g). Agency Approvals: CE.
DWYER INSTRUMENTS, INC.
P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Phone: 219/879-8000
Fax: 219/872-9057
www.dwyer-inst.com
e-mail: info@dwyermail.com
MODEL CHART Example 629C -01 -CH -P1 -E1 -S1 -3V 629C-01-CH-P1-E1-S1-3V
Series 629C Wet/wet differential pressure transmitter
Range 01
Housing CH Conduit housing, NEMA 4X (IP66) Process Connection
Electrical
Connection
Signal Output S1
Options 3V
*Pressures exceeding the working pressure limit may cause a calibration shift of up to ±3% of full scale.
02 03 04 05 06 07 08 09 11 12 13 14 15 16 17 18 19
P1 P2
E1 E2 E3 E5 E6
S3
AT FC LCD NIST
PRESET
0 to 5 psid 0 to 10 psid 0 to 25 psid 0 to 50 psid 0 to 100 psid 0 to 150 psid 0 to 200 psid 0 to 300 psid 0 to 500 psid 0 to 0.5 bar differential 0 to 1 bar differential 0 to 2 bar differential 0 to 4 bar differential 0 to 6 bar differential 0 to 10 bar differential 0 to 15 bar differential 0 to 20 bar differential 0 to 30 bar differential
1/4˝ male NPT 1/4˝ female NPT
Cable gland with 3´ of prewired cable Cable gland with 6´ of prewired cable Cable gland with 9´ of prewired cable
1/2˝ female NPT conduit
M-12 4 pin connector 4-20 mA Field selectable 0-5, 1-5, 0-10, 2-10 VDC 3-way valve Aluminum tag
Factory calibration certicate
LCD indication
NIST traceable certicate
Preset transmitter
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Loading...
+ 2 hidden pages