SERIES 477AV
HANDHELD DIGITAL MANOMETER
Measures Pressure, Flow and Velocity; ±0.5% Accuracy
TEST EQUIPMENT
29/32
41/64
[16.27]
1-1/16
[26.99]
BARBED FO
1/8 OR 3/16
ID TUBING
5-57/64
[149.68]
The new, upgraded SERIES 477AV HANDHELD DIGITAL MANOMETER is now
available with pressure, ow, and velocity measurements along with a number of other
convenient features. The 477AV uses a highly accurate differential pressure sensor to
offer ± 0.5% full scale accuracy. It displays negative, positive, and differential pressure.
For pressure, ow, and velocity there are selectable English and metric units, as seen
in the specications. The built-in air velocity and ow calculations provide accuracy and
conserve time associated with cumbersome manual calculations. Additionally, up to 40
readings can be saved—perfect for HVAC technicians making Pitot tube traverses of
airow readings across a duct. The accuracy that the 477AV series provides is critical
to maintenance personnel and technicians who require a highly accurate standard to
check their instrumentation or equipment, to ensure proper performance.
The digital display offers a backlight feature for easier viewing in darker areas.
Meanwhile, battery conservation is monitored and displayed in the event of low battery
voltage. The digital manometer will automatically shut off after 20 minutes to prevent
battery drain. This shut-off time can be reduced or disabled if desired. Series 477AV
can be eld-calibrated by setting zero and span values. Furthermore, the damping
feature compensates for the uctuating readings by averaging input values to display
a more stable readout. Included is an audible and visual alarm to warn over ow, over
pressure or over velocity.
Manometer, Portable
The Series 477AV features a menu structure outline printed on the back of the
aluminum casing. Comprehensive written instructions, a wrist strap, and a 9 Volt
alkaline battery are also included.
FEATURES/BENEFITS
• Pressure, ow, and velocity measurements
• Measures positive, negative, and differential pressure
• Operates up to 100 hours on a single 9 volt battery
• Numerous selectable English and metric units
• Stores up to 40 readings
• Menu structure detailed on the back of aluminum casing
• Aluminum case protects instrument from damage during transport/use
SPECIFICATIONS
Service: Air and compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±0.5% FS, 60 to 78°F (15.6
to 25.6°C); ±1.5% FS from 32 to 60°F
and 78 to 104°F (0 to 15.6°C and 25.6
to 40.0°C).
Pressure Hysteresis: ±0.1% of fullscale.
Pressure Limits: See chart.
Temperature Limits: 0 to 140°F (-17.8
to 60°C).
Compensated Temperature Limits: 32
to 104°F (0 to 40°C).
Storage Temperature Limits: -4 to
176°F (-20 to 80°C).
Display: 0.42˝ (10.6 mm) 4 digit LCD.
Resolution: See chart.
ACCESSORIES
Model Description
A-402A
UHH-C1
OPTION
To order add sufx: Description
-NIST NIST traceable calibration certicate
Example: 477AV-1-NIST
Carrying case; tough gray nylon pouch protects any
Series 477AV Manometer; double zippered for quick
and easy access, with a belt loop that snaps closed;
7-1/2˝H x 3˝W x 2-1/4˝D (191 x 76 x 57 mm)
Soft carrying case
Units of Pressure: in w.c., ft. w.c., in Hg,
2
, mm w.c., cm w.c., mm Hg,
psi, oz/in
mbar, Pa, kPa, hPa.
Units of Velocity: fpm, fps, mph, m/h,
m/s, k/h, knot.
Units of Flow: cfm, m
Power Requirements: 9 V Alkaline
battery, installed non-functional, user
replaceable.
Weight: 10.2 oz (289 g).
Process Connections: Two barbed
connections for use with 1/8˝ (3.18
mm) or 3/16˝ (4.76 mm) ID tubing. Two
compression ttings for use with 1/8˝
(3.18 mm) ID x 1/4˝ (6.35 mm) OD tubing
for 477AV-7 and 477AV-8 only.
Agency Approvals: CE.
3
/h, m3/s.
A-402A
UHH-C1
MODEL CHART
Model
477AV-000
477AV-00
477AV-0
477AV-1
477AV-2
477AV-3
477AV-4
477AV-5
477AV-6
477AV-7
477AV-8
DWYER INSTRUMENTS, INC. | www.dwyer-inst.comXXX
Pressure
Range
0-1.000 in w.c.
0-4.000 in w.c.
0-10.00 in w.c.
0-20.00 in w.c.
0-40.00 in w.c.
0-200.0 in w.c.
0-10.00 psi
0-20.00 psi
0-30.00 psi
0-100.0 psi
0-150.0 psi
Velocity Range Available Pressure Units
0-4004
0-8009
0-1.266k
0-1.791k
0-1.791k
0-56.63k
0-66.62k
0-94.22k
0-115.4k
0-210.7k
0-258.0k
20.34
40.69
64.33
90.97
128.7
287.7
338.4
478.6
586.2
1070
1311
-
0.1445
0.3613
0.7225
1.445
7.225
10.00
20.00
30.00
100.0
150.0
0.0736
0.2942
0.7355
1.471
2.942
14.71
20.36
40.72
61.08
203.6
305.4
0.2491
0.996
2.491
4.982
9.96
49.82
68.95
137.9
206.9
689.5
1034
1.000
4.000
10.00
20.00
40.00
200.0
276.8
553.6
830.4
2768
4152
1.868
7.473
18.68
37.36
74.73
373.6
517.1
1034
1551
5171
7757
2.491
9.96
24.91
49.82
99.6
498.2
689.5
1379
2069
6895
-
25.40
101.6
254.0
508.0
1016
5080
7031
-
-
-
-
249.1
996
2491
4982
9964
-
-
-
-
-
-
0.0833
0.3333
0.8333
1.667
3.333
16.67
13.07
46.13
69.20
230.7
346.0
0.5780
2.312
5.780
11.56
23.12
115.6
160.0
320.0
480.0
1600
2400
2
hPa cm w.c.
2.491
9.964
24.91
49.82
99.64
498.2
689.5
1379
2068
6895
-
2.540
10.16
25.40
50.80
101.6
508.0
703.1
1406
2109
7031
-
Maximum
Pressurefpm m/s psi in Hg kPa in w.c. mm Hg mbar mm w.c. Pa ft w.c. oz/in
5 psig
5 psig
5 psig
10 psig
10 psig
30 psig
30 psig
60 psig
60 psig
150 psig
200 psig