Series VBS Vibration Switch
Specifications - Installation and Operating Instructions
The Series VBS Vibration Switch is small, compact, and uses two easy
set up dials that adjust the maximum RMS velocity set point and false trip time delay. The Series VBS is intended to continuously monitor the changes in a machine’s vibration level. The VBS takes real-time RMS vibration input and provides an analog output of velocity, as well as a switching output when an alarm value is exceeded.
SAFETY INSTRUCTIONS
• The unit conforms to the relevant regulations and EC directives.
• Improper or unintended use may lead to malfunctions of the unit or to unwanted effects in your application.
• Installation, electrical connection, setup, operation and maintenance of the unit must only be carried out by qualified personnel authorized by the machine operator.
INSTALLATION
SPECIFICATIONS Housing Material: PBT, PC, FPM, and 316 SS. Temperature Limit: -22 to 221°F (-30 to 105°C). Accuracy: < ±3%. Measuring Range: 0 to 50 mm/s. Connections: M12 connector. Enclosure Rating: NEMA 6 (IP67). Electrical Rating: 18 to 32 VDC. Mounting Orientation: All. Nonlinearity: < ±0.25% of span. Switch Output Range: VBS-1: 0 to 25 mm/s Vrms;
VBS-2: 0 to 50 mm/s Vrms.
Analog Output Range: 10 to 1000 Hz. Output Signal: 4 to 20 mA. Switch Time Delay: 1 to 60 seconds. Switch Type: PNP normally open (500 mA max). Repeatability: < 0.5%. Weight: 0.25 lb (0.114 kg). Agency Approval: CE.
Figure 1
1. Mount only in a thick housing wall.
2. Ensure a safe vibration transmission and the signal direction is correct,
and allow no elastic intermediate layers. See Figure 1.
3. Tighten the sensor with a tightening torque of 15 Nm.
Phone: 219/879-8000 www.dwyer-inst.com
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyermail.com
OPERATION AND DISPLAY
1. Locking ring
2. Setting rings (manually adjustable after unlocking)
3. LED green: voltage supply
4. M8 process connection
5. LED yellow: lights when switching threshold and time delay exceeded.
See Figure 2.
Figure 2
WIRING
The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. See Figure 3.
RMS Set Effective value of the switching threshold, defining the limit value of the vibration velocity.
Delay Set Time in seconds during which the limit value must be effectively above the switching threshold (RMS Set) to activate the switching output (normally closed pin 4).
Output Behavior
Figure 3
1. Time delay after the switching threshold has been exceeded
2. Time delay after the switching threshold has been exceeded
3. Switch-off
4. Switching threshold
5. Delay Vss = Vibration velocity t = time
Figure 3
Implementation of the Time Delays
The time delay starts when the defined switching threshold is exceeded (1) / (2). The time delay is cancelled when the value falls below the switching threshold (without switch-off). The switch-off is triggered when the switching threshold is exceeded during a full time delay (3).
MAINTENANCE/REPAIR
Upon final installation of the Series VBS no routine maintenance is required. The Series VBS is not field serviceable and should be returned if repair is needed. Field repair should not be attempted and may void warranty.
WARRANTY/RETURN
Refer to “Terms and Conditions of Sales” in our catalog and on our website. Contact customer service to receive a Return Goods Authorization number before shipping the product back for repair. Be sure to include a brief description of the problem plus any additional application notes.
©Copyright 2014 Dwyer Instruments, Inc. Printed in U.S.A. 4/14 FR# R6-443973-00 Rev. 1
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyermail.com
Loading...