Dwyer TLVT1 User Manual

Model TLVT1
Digital Touchscreen Programmable Thermostat with Heat Pump 120515
CAUTION:
2. The installer must be a trained service engineer.
3. Disconnect the supply before battery replacement.
4. Do not dispose the used up battery with the household waste. Please refer to your local area for proper disposal.
5. It must be mounted on a dry clean indoor place.
Feature List
Thermostat / Heat-pump Selection (software selectable) Fan On / Auto Battery Powered (2 “AA” alkaline batteries) 7-day (Monday to Sunday), 4-timezone section and
temperature program settings
Temperature display in
o
F or oC
Temperature Measurable Range : 32 ~ 99
o
F / 0 ~ 40oC
Program Copy for fast programming EEPROM stores heat and cool program settings Program Override Mode (Temporary / Permanent) Real clock in 12 hr / 24 hr Filter, energy and UV lamp usage record Adjustable interval time for filter, energy and UV usage Energy Saving Index Defrost function Cleaning Screen mode Calendar Holiday Mode Security Mode
Wiring
When two-transformer system is used, connect the wires to
R
H
and RC accordingly to the diagram shown. When single-transformer system is used, connect RH and RC together.
There are two wiring configurations: thermostat or
heat-pump. Please select the configuration to be used and then connect the appliances accordingly.
Thermostat
Terminals
Device
RH
24Vac supply for heater
RC 24Vac supply for cooler
W 1st stage heating
W2
2nd stage heating
Y 1st stage cooling
Y2
2nd stage cooling
G
Fan
Heat-pump
Terminals
Device
RH
24Vac supply
RC
E
Emergency Heat
W2
Auxiliary Heat
Y 1st stage compressor
Y2
2nd stage compressor
G
Fan
B
Changeover valve for heat
O
Changeover valve for cool
Pull all cables back into wall prior to avoid trapping wires. Do not use metal conduit or of cable provided with a metal sheath. Recommend adding fuse or protective device in the live circuit.
Mounting
1. Base housing I. Adjust the base on the wall or junction box and ensure
the base is at surface level and cover the junction box comfortably.
II. If necessary, pull the cables out at the middle hole of the
base.
III. If necessary, place the 2 pcs of wall anchors at the wall. IV. Fasten the base with the 2 pcs of long screws. V. Place the cables at the hole near the terminal block.
2. Insert 2 AA batteries into the battery case on the thermostat (Please observe polarity).
3. Hold the thermostat on the base. Align the screw blocks with the pins on the back of the thermostat.
4. Push the thermostat straight onto the base until snaps into place.
Setup Mode
There are 10 settings in the setup mode:
1. Calendar
2. 12 / 24 hour selection
3. oC / oF display selection
4. HE / HG selection
5. Thermostat / Heat-pump selection
6. Control system selection
7. Span and Differential selection
8. Delay / Long Delay selection
9. DST (Daylight Saving Time) Selection
10. Screen lock selection
To enter setup mode, press and hold SYSTEM for 5 seconds. In setup mode, press EXIT to discard changes made to current setting and exit setup mode. Press CONFM to apply changes and proceed to next setting.
Set Calendar
Press / to change year, month and day accordingly. Press CONFM to apply changes and proceed to next setting.
12/24 hour
Press / to toggle between 12 and 24 hour mode. Press CONFM to apply changes and proceed to next setting.
o
C / oF Selection
Press / to toggle between oC or oF temperatuire unit. Press CONFM to apply changes and proceed to next setting.
HE / HG Selection
Press / toggle between HE / HG selection. Press CONFM to apply changes and proceed to next setting. When fan is in auto mode and HE is selected, fan will be turned on as long as heater / cooler is turned on. When fan is in auto mode and HG is selected, fan will only be turned on during cool mode.
HE
HG
Heat On
Fan On
Fan Off
Cool On
Fan On
Fan On
* Heat-pump discard HE/HG selection except for emergency heat
Thermostat / Heat-pump
Press / to toggle between thermostat and heat-pump selection.
“th” represents thermostat. “HP represents heat-pump.
Press CONFM to apply changes and proceed to next setting.
Control System Selection
Press / to toggle between control system selection. Press CONFM to apply changes and proceed to next setting.
Selectable configurations are shown as follow :
Thermostat
Configuration
Display
Terminal Conection
1 heat 1 cool
1H1C
RH, RC, W, Y
1 heat 2 cool
1H2C
RH, RC, W, Y, Y
2
2 heat 1 cool
2H1C
RH, RC, W, W2, Y
2 heat 2 cool
2H2C
RH, RC, W, W2, Y, Y
2
* Connect fan ( terminal : G ) if necessary.
Heat-pump
Configuration
Display
Terminal Conection
1 heat 1 cool
1H1C
RH, RC, Y,, B, O
2 heat 2 cool
2H2C
RH, RC, Y, Y2, B, O
2 heat 2 cool
Axuliary heat
3H2C
RH, RC, W2, Y, Y
2
* Connect fan ( terminal : G ) if necessary. * Emergency Heat ( terminal : E ) is used for defrost control. Connect it if necessary.
Span and differential Selection
“P” represents span setting. “d” represents differential setting. Span and differential setting units will be changed according to the temperature unit selected by user. The selectable values are 0.5°C(1°F) / 1.0°C(2°F) / 1.5°C(3°F). The default span and differential settings are 0.5oC / 1oF. Press / to change the values. Press CONFM to apply changes and proceed to next setting.
Delay / Long Delay Selection
Press / to toggle between delay and long delay selection. Press CONFM to apply changes and proceed to next setting. Delay for heat / cool on to prevent short cycling of system that may damage the appliance. “dE” represents delay. “L dE” represents long delay.
Delay
Long delay
Heat mode
5~10 sec
4~5 min
Cool mode
4~5 min
4~5 min
For Heat-pump configuration, it will always be a long delay irrespecting to this selection setting.
DST (Daylight Saving Time)
Press / to toggle on/off of the DST function.
* The DST used is based on USA time-zone.
Secure Lock Selection
Press or to enable(ON) or disable(OFF) the security
lock. If it is enabled, user is required to input a 4-digits password.
Press or on the left to change the password. P1 indicates
that the 1st digit password (read from left) is selected. Press or
on the right to select the digit.
After setting all 4 digits, press CONFM to activate the security
mode.
When security mode is activated, “ ” is shown on the LCD and
all keys are disabled expect SYSTEM .
* If the password is 8888, all settings will restore to default upon
pressing CONFM .
Disable the security lock
1. Press SYSTEM and user is required to enter the correct password.
2. If the password is correct, the security lock will be disabled. Otherwise, it remains locked.
* Security Lock cannot be maintained once power is lost.
View Calendar
1. Press the current weekday to view current date.
2. Press EXIT to exit the viewing.
Clock Setting
1. Press CLOCK to enter the clock setting mode.
2. Firstly, the hour is shown. Press or to change the
hour. Press CONFM to save the setting.
3. Then, the minute is shown. Press or to change the
minute. Press CONFM to save the setting and exit clock setting.
Clean Screen Mode
1. Press CLEAR to enter the cleaning screen mode.
2. The screen will show a 20-second countdown immediately after
the key press.
3. During countdown, all keys are disabled.
4. When countdown reaches zero, press EXIT to exit clean
screen mode, or press CLEAR to repeat the countdown.
Usage
TLVT1 can record the Filter, UV and energy usage. These counters count hourly. Each count is 4 digits long (0~9999). Filter usage counts when the fan is turned on; UV usage counts as long as TLVT1 is powered on. Energy usage counts when heater / cooler is turned on. When the counts reach the set limit, the corresponding usage icon will be shown on the screen.
View Usage
1. Press USAGE to enter the usage mode.
2. Filter, UV and Energy counter are shown alternatively by
pressing USAGE .
3. Press CLEAR to clear the current counter records.
4. Press EXIT to exit the usage mode.
Adjusting Usage limit
1. Press and hold USAGE for 3 seconds during the usage mode.
2. Press or to change the internal time (0~9999).
3. Press CONFM to save the setting.
4. Press EXIT to exit the limit setting.
Defrost
When the room temperature is below 5 oC / 41 oF, HEATER will always be turned ON and COOLER will be turned OFF irrespective of the current control temperature set. 2nd stage heater, emergency and auxiliary heater may be turned on depending on
the control system configuration. “ ”Defrost indicator will be shown on screen.
Program mode
Default programs are as the below:
Heat settings :
Wake
Out
Back
Sleep
Mon
6:00
(21 oC/70 oF)
8:00
(16 oC /61 oF)
18:00
(21 oC /70 oF)
22:00
(16 oC /61 oF)
Tue
6:00
(21 oC /70 oF)
8:00
(16 oC /61 oF)
18:00
(21 oC /70 oF)
22:00
(16 oC /61 oF)
Wed
6:00
(21 oC /70 oF)
8:00
(16 oC /61 oF)
18:00
(21 oC /70 oF)
22:00
(16 oC /61 oF)
Thu
6:00
(21 oC /70 oF)
8:00
(16 oC /61 oF)
18:00
(21 oC /70 oF)
22:00
(16 oC /61 oF)
Fri
6:00
(21 oC /70 oF)
8:00
(16 oC /61 oF)
18:00
(21 oC /70 oF)
22:00
(16 oC /61 oF)
Sat
6:00
(21 oC /70 oF)
10:00
(16 oC /61 oF)
18:00
(21 oC /70 oF)
23:00
(16 oC /61 oF)
Sun
6:00
(21 oC /70 oF)
10:00
(16 oC /61 oF)
18:00
(21 oC /70 oF)
23:00
(16 oC /61 oF)
Cool setting:
Wake
Out
Back
Sleep
Mon
6:00
(26 oC /79 oF)
8:00
(29.5 oC /85 oF)
18:00
(26 oC /79 oF)
22:00
(28 oC /82 oF)
Tue
6:00
(26 oC /79 oF)
8:00
(29.5 oC /85 oF)
18:00
(26 oC /79 oF)
22:00
(28 oC /82 oF)
Wed
6:00
(26 oC /79 oF)
8:00
(29.5 oC /85 oF)
18:00
(26 oC /79 oF)
22:00
(28 oC /82 oF)
Thu
6:00
(26 oC /79 oF)
8:00
(29.5 oC /85 oF)
18:00
(26 oC /79 oF)
22:00
(28 oC /82 oF)
Fri
6:00
(26 oC /79 oF)
8:00
(29.5 oC /85 oF)
18:00
(26 oC /79 oF)
22:00
(28 oC /82 oF)
Sat
6:00
(26 oC /79 oF)
10:00
(29.5 oC /85 oF)
18:00
(26 oC /79 oF)
23:00
(28 oC /82 oF)
Sun
6:00
(26 oC /79 oF)
10:00
(29.5 oC /85 oF)
18:00
(26 oC /79 oF)
23:00
(28 oC /82 oF)
1. Press PROG to enter the program mode.
2. Default start from “MON” and “WAKE”.
3. Current program of setting is without .
4. Press / to change the time, heat and cool setting temperature.
5. Press EXIT to go back to normal mode.
6. Press CONFM to save setting and go back to normal mode.
7. Press COPY to copy the program.
8. During copying, the heat and cool setting temperatures are not set but still can be checked by pressing WAKE, OUT , BACK and SLEEP.
9. Press the other days to copy the program. The days that are copied will also be without .
10. Press “COPY” again to finish the copy mode and return to program setting mode.
Override mode
1. Press to select permanent override, temporary
override and program.
2. Default heat and cool setting temperature for override and
permanent override mode is 26 oC / 79 oF.
3. Press / to change the override setting temperature in
heat and cool mode respectively. Temporary override mode returns to normal mode when new program starts if override time does not set.
Holiday Mode
1. Select system to temporary override.
2. Press and hold OVERRIDE for about 3 seconds to enter
holiday mode setting.
3. User may set the time interval for the holiday mode
duration. Value on the left refers to number of hours and that on the right refers to number of days.
4. Press / to adjust the values.
5. Press CONFM to apply changes, or EXIT to discard
changes.
6. When holiday mode is activated, OVERRIDE flashes.
7. The thermostat will keep using the current setting
temperature until the holiday time duration reaches zero. It then returns to program mode.
8. To disable holiday mode, any one of the three methods can
be done.
i. Change system to permanent override mode.
ii. Change system to normal mode.
iii. Set the holiday time interval to zero.
System setting
In Normal mode, press and release SYSTEM to enter system
mode.
User may set the system used by pressing SYSTEM.
It follows the sequence below:
(HEAT EM)  HEAT COOL AUTO OFF HEAT
HEAT EM
It is the same as HEAT mode, except that it would turn on emergency heat instead of compressor ( Heat-pump
MODE
only ).
HEAT MODE
Heating appliances will be activated when the room temperature is lower than the setting temperature.
COOL MODE
Cooling appliances will be activated when the room temperature is higher than the setting temperature.
AUTO MODE
The unit will use the current heat and cool setting temperature to turn on heating or cooling appliances.
OFF MODE
No heating and Cooling will be activated at any temperature.
“LO” will be shown on the screen when room temperature is below 0 oC / 32 oF. “HI” will be shown on the screen when room temperature is above 40 oC / 99 oF.
When one appliance is turned on, will be shown on the screen as indication.
Similarly, will be shown on the screen when second appliance is turned on.
Emergency Heat
When it is activated, “EM.” will be shown on the screen.
Auxiliary Heat
When it is activated, “AUX” will be shown on the screen.
FAN mode
Press FAN to enter fan mode. In the fan mode, press FAN to
toggle the Fan controls (FAN ON or FAN AUTO).
FAN ON: Fan stays on all the time. FAN AUTO: Fan turns ON whenever heating or Cooling is on
(Depends on HE/HG setting).
Energy saving index
The energy saving index is calculated based on the setting of your program. It is used as a reference for the user to know how likely the program is to conserve energy or consume more. If the user sets a comfort program setting, the appliances are likely to be turned on a lot and “LOSE” may be shown on the screen. If the appliances are less likely to be turned on, “SAVE” may be shown on the screen. The likelihood of saving energy or losing energy is converted to a percentage value for reference. If the value is higher than 99%, “HI” will be shown instead.
Low battery
If the voltage batteries drop below 2.7V, icon will be on.
Electrical Interface
Temperature measurement: 0~40 oC / 32~99 oF Control temperature range: 5~35 oC / 41~95 oF Temperature resolution: 0.5 oC 1 oF Temperature accuracy: ±0.5 oC / ±1 oF Battery: 2 AA alkaline battery Relay contact Voltage: 24Vac 50/60Hz Relay contact Current: 1A Max