Bulletin H-2-TG
Series TG Polycarbonate Wall Mount Thermostat Covers
Specifications - Installation and Operating Instructions
3.000
2.890
[73.4]
MAXIMUM
INTERNAL
FOOTPRINT
FOOTPRINT
2.000
[50.8]
MAXIMUM
INTERNAL
[76.2]
2.125
[53.98]
[118.1]
MAXIMUM
INTERNAL
FOOTPRINT
4.750
[120.7]
MAXIMUM
INTERNAL
FOOTPRINT
2.930
[74.4]
4.840
[122.9]
MAXIMUM
INTERNAL
FOOTPRINT
6.650
[168.9]
4.650
MAXIMUM
INTERNAL
FOOTPRINT
6.890
[175]
6.750
[171.5]
9.450
[240]
The Series TG Polycarbonate Thermostat Cover
prevents physical damage and unauthorized adjustments of
thermostats. Two sizes of covers are available to fit most
common thermostats and transmitters. The low profile
design with ventilation slits allows exceptional air flow in
order to obtain accurate measurements.
TOOLS LIST
Included:
1 Series TG Thermostat Cover
2 Keys
4 Concrete Screws
4 Drywall Screws
4 Plastic Anchors
Tools Required:
Pencil
Hammer
#2 Phillips Screwdriver
5/16˝ (8 mm) nut driver (for concrete screws)
Hand Drill
9/32˝ (7.1 mm) drill bit (drywall screws)
5/32˝ (4 mm) drill bit (concrete screws)
Fig. 1
Mounting Screws, Concrete screw on the left,
Drywall screw on the right.
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
MOUNTING
Note: The Series TG cover comes off the mounting
base (it does not rotate on hinge).
Step 1: Removing the Cover
A) Use the key to unlock the cover.
B) Open the cover approximately 15 degrees.
C) Slide the cover off the hinge.
Step 2: Mount the Base
A) Place the cover over the device to be protected and
mark the mounting holes using a pencil.
B) Cover the device to be protected with a damp towel
to prevent dust from getting into the device.
C) For drywall applications, drill four 9/32˝ (7.1 mm)
holes in the marked location from step 2A. For
concrete or cinder block applications, drill four
5/32˝ (4 mm) holes to a depth of 1-3/4˝ (45 mm) in
the marked location from step 2A. Skip step 2D for
concrete and cinder block applications.
D) Insert the plastic anchors until they are flush with the
wall surface.
E) Attach the base to the wall using the appropriate
screws provided.
Fig. 2
Mounting Diagram
Step 3: Re-Attach Cover
A) Slide cover hinge slots over the hinge tabs on the
base.
B) Close cover to base.
C) Use the key to lock the cover in place.
Note: Replacement keys may be purchased from the
factory using model number TG-KEY.
MAINTENANCE
Upon final installation of the Series TG Polycarbonate Wall
Mount Thermostat Covers, no routine maintenance is
required. The Series TG is not field serviceable and should
be returned if repair is needed (field repair should not be
attempted and may void warranty). Be sure to include a
brief description of the problem plus any relevant
application notes. Contact customer service to receive a
return goods authorization number before shipping.
©Copyright 2008 Dwyer Instruments, Inc. Printed in U.S.A. 6/08 FR# R6-443634-00
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Phone: 219/879-8000 www.dwyer-inst.com