Bulletin F-76-SSV
Series SSV Solenoid Valves
Specifications - Installation and Operating Instructions
SSV-B SSV-S
Series SSV Solenoid Valves are compact, general-service, two-way guide type
solenoid valves for air, gas, water, and other liquid applications. They are available
n brass and stainless steel with a normally open design and can be oriented in any
i
osition. The solenoid enclosure provides protection against dust, while also
p
rotecting against seepage of oil and non-corrosive coolants. The Series SSV have
p
a maximum process temperature of 248°F (120°C). The series offers a wide range
of valve sizes and flow ranges, with connection sizes from 1/8˝ to 2˝ NPT and
orifices from 3 mm to 50 mm.
50 Hz (VA)
Voltage
220 VAC
110 VAC
24 VDC
Model
SSV-B1N1
SSV-B2N1
SSV-B3N1
SSV-B4N1
SSV-B5N1
SSV-B6N1
SSV-B7N1
SSV-B8N1
SSV-B9N1
Note: Add -BSPP to the end of the model number for
female BSPP end connections.
Inrush
82
82
-
SSV-S1F1
SSV-S2F1
SSV-S3F1
SSV-S4F1
SSV-S5F1
SSV-S6F1
SSV-S7F1
SSV-S8F1
SSV-S9F1
Holding
33
33
-
60 Hz (VA)
Inrush
82
82
-
Connection,
NPT
1/8˝
1/4˝
3/8˝
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
Holding
28
28
-
Orifice
in (mm)
0.12 (3)
0.12 (3)
0.51 (13)
0.51 (13)
0.79 (20)
0.98 (25)
1.38 (35)
1.57 (40)
1.97 (50)
DC
(W)
-
32
Voltage
110 VAC
110 VAC
110 VAC
110 VAC
110 VAC
110 VAC
110 VAC
110 VAC
110 VAC
odel
M
SV-S1FX
S
SV-S2FX
S
SV-S3FX
S
SSV-S4FX
SSV-S5FX
SSV-S6FX
SSV-S7FX
SV-S8FX
S
SV-S9FX
S
PECIFICATIONS
S
ervice: Compatible gases and liquids.
S
ine Size: 1/8 to 2˝ NPT or BSPP.
L
End Connections: Female NPT or BSPP.
Operating Pressure:
1/8 to 1/4˝: 0 psi (0 bar) to 87 psi (6 bar);
3/8 to 2˝: 7.3 psi (0.5 bar) to 116 psi (8 bar).
Pressure Limit: 174 psi (12 bar).
Wetted Material:
SSV-B: Body: Brass; Spring: 304 SS; Seal: NBR;
SSV-S: Body: 316 SS; Spring: 304 SS; Seal: Fluoroelastomer.
Temperature Limits:
Process: 248°F (120°C);
Ambient: 32 to 149°F (0 to 65°C).
Power Requirements: Standard: 110 VAC; Optional: 220 VAC; 24 VDC consult
factory. See Series SRC Solenoid Coils.
Power Consumption: See table.
Enclosure Rating: NEMA 13 (IP54).
Electrical Connection: DIN connection.
Other Materials: Nylon.
Mounting Orientation: Any position, best if solenoid vertically above valve.
Weight: See table.
Type of Operation: NO.
A
in [mm]
-5/8 [41]
1
-5/8 [41]
1
-19/32 [66]
2
2-19/32 [66]
2-61/64 [75]
3-25/32 [96]
5-5/32 [131]
-5/32 [131]
5
-1/2 [165]
6
B
in [mm]
-9/64 [29]
1
-9/64 [29]
1
-57/64 [48]
1
1-57/64 [48]
2-9/32 [58]
2-3/4 [70]
3-25/32 [96]
-25/32 [96]
3
-47/64 [120]
4
C
in [mm]
-15/32 [88]
3
-17/64 [83]
3
-57/64 [124]
4
4-57/64 [124]
5-1/8 [130]
5-5/8 [143]
6-7/32 [158]
-7/32 [158]
6
-3/64 [179]
7
Weight lb [kg]
SSV-S
.88 [0.40]
0
.86 [0.39]
0
.09 [0.95]
2
1.98 [0.90]
2.42 [1.10]
3.30 [1.50]
6.16 [2.80]
.94 [2.70]
5
0.1 [4.60]
1
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyermail.com
NSTALLATION
I
heck the product label for correct catalog number and voltage.
C
OSITIONING/MOUNTING
P
The solenoid is designed to perform properly when mounted in any position. However
for optimum life and performance, the solenoid should be mounted vertical and
upright so as to reduce the possibility of foreign matter accumulating in the core tube
rea.
a
MPORTANT: For the protection of the solenoid valve, install a strainer or filter
I
uitable for the service involved on the inlet side of the valve as close to the valve as
s
possible.
WIRING
iring must comply with local codes and the National Electrical Code. To facilitate
W
iring, the solenoid may be rotated 360°.
w
1. The open-frame solenoid is provided with DIN terminals to accommodate the
plug connector kit.
2. Remove center screw from plug connector. Remove the screw from the terminal
block and using a small screwdriver, pry the terminal block from the connector
over.
c
. Use #12-18 AWG stranded copper wire rated at 90°C or greater for connections.
3
trip the wire leads back approximately 1/4˝ for installation in socket terminals. The
S
use of wire-end sleeves is also recommended for these socket terminals. Maximum
length or wire-end sleeves to be approximately 1/4˝. Thinning of the ends of the
lead wires is not recommended.
4. Thread wire through gland nut, gland gasket, washer and connector cover. NOTE:
onnector cover may be rotated in 90° increments for alternate positioning of cable
C
ntry.
e
. Check DIN connector terminal block for electrical markings. Then make electrical
5
connection to terminal block according to markings on it. Snap terminal block into
connector cover and install the terminal block and center screw.
6. Install the plug connector on the solenoid.
SOLENOID TEMPERATURE
Standard catalog valves are supplied with coils designed for continuous duty service.
When the solenoid is energized for a long period, the solenoid enclosure becomes hot
and should not be touched.
WARNING
pipelines for repairs.
Turn off electrical power supply and depressurize valve before
making repairs. It is not necessary to remove the valve from the
LEANING
C
periodic cleaning of all solenoid valves is desirable. The time between cleaning will
A
ary depending on medium and service conditions. In general, if the voltage to the coil
v
s correct, sluggish valve operation, excessive noise or leakage will indicate cleaning
i
is required. Clean valve strainer or filter when cleaning the solenoid valve.
PREVENTIVE MAINTENANCE
. Keep the medium flowing through the valve as free from dirt and foreign material
1
s possible.
a
. While in service, operate the valve at least once a month to insure proper opening
2
nd closing.
a
3. Periodic inspection (depending on medium and service conditions) of internal valve
parts for damage or excessive wear is recommended. Thoroughly clean all parts.
Replace any parts that are worn or damaged.
MPROPER OPERATION
I
. Faulty Control Circuit: Check the electrical system by energizing the solenoid. A
1
metallic click signifies the solenoid is operating. Absence of the click indicates loss
of power supply. Check for loose or blown fuses, open-circuit or grounded coil,
broken lead wires or spliced connections.
2. Burned-Out Coil: Check for open-circuit coil. Replace coil if necessary.
. Voltage: Check voltage across the coil leads. Voltage must be at least 85% of
3
tated rating.
s
SOLENOID REPLACEMENT
1. Disconnect the conduit, coil leads, and grounding wire.
2. Remove the center screw from the DIN plug connector. Disconnect the DIN plug
connector from the adapter. Remove the locknut, DIN terminal adapter, and gasket
rom the solenoid.
f
. Remove the coil from the plunger tube assembly.
3
. Reassemble reversing the previous steps.
4
MAINTENANCE/REPAIR
Upon final installation of the Series SSV, no routine maintenance is required. The
Series SSV is not field serviceable and should be returned if repair is needed. Field
repair should not be attempted and may void warranty.
WARRANTY/RETURN
Refer to “Terms and Conditions of Sales” in our catalog and on our website. Contact
customer service to receive a Return Goods Authorization number before shipping the
product back for repair. Be sure to include a brief description of the problem plus any
additional application notes.
©Copyright 2014 Dwyer Instruments, Inc. Printed in U.S.A. 3/14 FR# RV-443574-00 Rev.1
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyermail.com