Wiring & Installation Diagram
for
SSR-2 Solid State Relay
Typical Wiring Diagram
Brass Term.
SW. LOAD
Sensor
Switch
Wires connecting external sensor switches to SSR-2 relays should not be placed in raceways or conduits containing
high voltage lines. Voltages induced from these lines may trigger the low-power, solid-state triac; causing it to turn "on"
momentarily.
SSR-2
(Top View)
LOAD
VAC
Neutral
Surge Current Ratings
(Non-Repetitive)
Part
Number
SRR-25
SRR-210
SSR-2 Rating
5 Amps, AC
10 Amps, AC
.010 Sec.
Overload Time
1.0 Sec.
Overload, Amps
30
50
20
30
10 Sec.
10
15
Note: Mechanical holding or latching
contacts (contactors) may cause some
loads to latch under transient conditions.
Hot
Specifications
Operating & Load Voltage Range
Voltage Loss
Sensor Current, Max.
Allowable Resistance in Sensor
Circuit to Turn "ON" (Max.)
Leakage Current Thru Load Term.
Switching Mode
Operating Temperature
DWYER INSTRUMENTS,INC.
P .O.BOX 373 MICHIGAN CITY, INDIANA 46361, U.S.A.
24 to 260 VAC
2 VAC
20 mA
4 kΩ@ Nom. Volt.
12 mA @ 240 VAC
SPST, N.O.
0°F to 120°F (-17.8°C to 48.9°C)
Phone: 219/879-8000 www.dwyer-inst.com
Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Lit-By Fax: 888/891-4963