Dwyer RDCS User Manual

Bulletin V-DCS/RDCS
Series DCS/RDCS Springless Diaphragm Valves
Specifications - Installation and Operating Instructions
DCS35T1D
DCS35C1D
The Series DCS/RDCS Springless Dust Collection Valves are ideal
for use with the Series DCT1000 and Series DCT500 duct collection timer boards. A springless design offers not only durability, but also reliability for an exceptional cleaning pulse. Both the Series DCS and RDCS have the option for either coupling or NPT connections. The coupling connection allows for a quick and simple installation. Only the stub pipe and blowtube need to be cleaned and deburred before the valve is fit into position. The “T” Series DCS has female threaded connections and the “C” Series DCS has a coupling connection. Both the “T” and “C” versions have a 90° angle between the inlet and outlet: the most suitable configuration for pulse valve applications. The valves are offered in both integrated and remote coil configurations.
Models
Size
Model RDCS20T RDCS20C DCS20T1D DCS20C1D RDCS25T RDCS25C DCSS25T1D DCSS25C1D RDCS35T RDCS35C DCS35T1D DCS35C1D
*110 VAC with DIN Connector
3/4˝
1-1/2˝
Solenoid
Remote Remote Integral* Integral* Remote Remote Integral* Integral* Remote Remote Integral* Integral*
Connection
NPT Coupling NPT Coupling NPT Coupling NPT Coupling NPT Coupling NPT Coupling
Number of Diaphragms
1
1
1
Cv Factor (gal/min)
14
23
42
RDCS20C
RDCS35T
SPECIFICATIONS Service: Compatible gases, filtered and oil free. Wetted Materials:
Body: Aluminum; Diaphragm disc: Thermoplastic polyurethane; Solenoid seals: NBR.
Other Materials:
Cover: Aluminum; Body bolts: Zinc plated SS;
Solenoid: Nylon. Pressure Limits: Minimum of 4.4 psi (0.3 bar), maximum of 124.7 psi (8.6 bar).
Temperature Limits:
Ambient: -4 to 140°F (-20 to 60°C);
Operating: -4 to 185°F (-20 to 85°C).
Power Requirements: 110 VAC, 220 VAC, or 24 VDC for DCS models. Power Consumption: 12 W, inrush: 17 VA; H olding: 14.5 VA for DCS
models.
Electrical Connection: DIN connection for DCS models. Enclosure Rating: NEMA 4X (IP65) for DCS models. Process Connection: See model chart. Mounting Orientation: Any position.
RDCS35C
Series DCS/RDCS Model Guide
Construction
Size
Connection
Voltage
DWYER INSTRUMENTS, INC.
DCS RDCS
20 25 35
Integrated coil Remote coil 3/4˝ 1˝ 1-1/2˝
T
NPT
C
Coupling
1D
110 VAC DIN (for integrated coil only)
2D
220 VAC DIN (for integrated coil only)
3D
24 VDC DIN (for integrated coil only)
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
C
C
B
E
D
A
B
E
D
A
C
C
B
E
D
A
B
E
D
A
DCSxxCxD
DCS Dimensional Chart
Connection NPT
Model DCS20TxD DCS25TxD DCS35TxD
Coupling
DCS20CxD DCS25CxD DCS35CxD
A (mm)
3-1/8˝ (79.38) 3-19/64˝ (83.74) 4-11/32˝ (110.33) 4-9/64˝ (105.17) 4-7/16˝ (112.71) 5-23/64˝ (136.13)
B (mm)
4-57/64˝ (124.22) 5-9/16˝ (141.29) 6-3/64˝ (153.59) 5-9/16˝ (141.29) 7-1/32˝ (178.59) 7-45/64˝ (195.68)
C (mm)
2-45/64˝ (68.66) 2-53/64˝ (71.83) 3-1/2˝ (88.9) 2-45/64˝ (68.66) 2-53/64˝ (71.83) 3-1/2˝ (88.9)
DCSxxTxD
D (mm)
1-37/64˝ (40.08) 1-55/64˝ (47.23) 2-17/32˝ (64.29) 2-39/64˝ (66.28) 3˝ (76.20) 3-35/64˝ (90.09)
E (mm)
1-15/64˝ (31.35) 1-31/64˝ (37.70) 1-15/32˝ (37.31) 1-51/64˝ (45.64) 2-49/64˝ (70.25) 2-61/64˝ (75.01)
RDCSxxC
RDCSxxT
RDCS Dimensional Chart
Connection NPT
Coupling
Model RDCS20T RDCS25T RDCS35T RDCS20C RDCS25C RDCS35C
A (mm)
3-1/8˝ (79.38) 3-19/64˝ (83.74) 4-11/32˝ (110.33) 4-9/64˝ (105.17) 4-7/16˝ (112.71) 5-23/64˝ (136.13)
B (mm)
2-47/64˝ (69.45) 3-7/32˝ (81.76) 3-43/64˝ (93.27) 3-25/64˝ (86.1) 4-43/64˝ (118.67) 5-21/64˝ (135.33)
C (mm)
2-45/64˝ (68.66) 2-53/64˝ (71.83) 3-1/2˝ (88.9) 2-45/64˝ (68.66) 2-53/64˝ (71.83) 3-1/2˝ (88.9)
D (mm)
1-37/64˝ (40.08) 1-55/64˝ (47.23) 2-17/32˝ (64.29) 2-39/64˝ (66.28) 3˝ (76.20) 3-35/64˝ (90.09)
E (mm)
1-15/64˝ (31.35) 1-31/64˝ (37.70) 1-15/32˝ (37.31) 1-51/64˝ (45.64) 2-49/64˝ (70.25) 2-61/64˝ (75.01)