Dwyer BBV-0N Manual

Series BBV-0 2-Valve Block Manifold
PROCESS
ISOL
INSTRUMENT
By Dwyer
Specications - Installation and Operating Instructions
Bulletin V-BBV-0
BBV-0F
BBV-0N
The SERIES BBV-0 2-Valve Block Manifold is perfect for use over a broad range of
industrial applications including oil reneries, nuclear power stations, petrochemical processing, and more. The Series BBV-0 is forged from 316 stainless steel bar stock and designed to withstand repeated open and close operations. Suited to control oil, water, toxic uids, chemicals, air, and steam; the 2-valve block manifold has (1) isolate and (1) vent valves. Each valve stem is precision machined with hard seats to reduce operating torque.
The BBV-0F and BBV-0N are designed to mount directly to industrial pressure transmitters. The BBV-0F comes with two 7/16-20 UNF mounting bolts and one PTFE gasket.
INSTALLATION
Refer to the drawing shown above. The connections to the device must be made accordingly. The BBV-0 2-Valve Block Manifold can be mounted in any position. The BBV-0 is tted with color-coded caps for valve identication:
ISOLATE (Blue) VENT (Red) The BBV-0 2-Valve Block Manifold require periodic maintenance. It is recommended to change the sealing gaskets periodically for safety.
VENT
ATE
FLOW DIAGRAM
SPECIFICATIONS
Service: Compatible liquids, gases, or steam.
End Connections: Process connection: 1/2˝ male NPT; Instrument connection: No ange: 1/2˝ female NPT; Flange: 1/2˝ DIN 19213 ange; Vent/test: 1/4˝ female NPT.
Wetted Materials: Body, stem, valve assembly: 316 SS; Stem packing: PTFE. Pressure Limit: 6000 psi (400 bar). Temperature Limit: 464°F (240°C). Other Materials: Handle: 304 SS.
MAINTENANCE
After nal installation of the block valve, some routine maintenance is required. The Series BBV-0 is not eld repairable, with the exception of previously stated maintenance, and should be returned if repair is needed (eld repair should not be attempted and may void the warranty). Be sure to include a brief description of the problem plus any relevant application notes. Contact customer service to receive a return goods authorization (R.G.A.) number before shipping.
CAUTION
2. Do not remove the safety pin provided on the body.
3. Do not use the BBV-0 2-Valve Block Manifold above the recommended working pressure and temperature given in the specications.
W.E. ANDERSON
1. Do not remove the instrument from BBV-0 2-Valve Block Manifold when the system is under pressure.
A DIVISION OF DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
Phone: 219/879-8000
Fax: 219/872-9057
www.dwyer-inst.com
e-mail: info@dwyermail.com
[118.00]
[60.00]
MOUNTING HOLES
4-17/32
FEMALE
[190.15]
DIMENSIONS
7-31/64
4-41/64
1-47/64
[44.00]
1-17/64
[32.00]
3-15/64
[82.00]
PORT (PLUGGED)
2-23/64
1/4˝ NPT VENT
1-17/64
[32.00]
1/2˝ NPT PROCESS
CONNECTION
BBV-0F
1/2˝ NPT MALE
3-3/4
[95.00]
MAX OPEN
1-5/8
[41.30]
[115.00]
3-5/8
[92.00]
MAX. OPEN
2X Ø15/32
[Ø12.00]
1/2˝ NPT
BBV-0N