Model A-SPPM-TC Thermocouple Input Board for the SPPM
Installation and Operating Instructions
The Model A-SPPM-TC Thermocouple Input Board is an add-on
module that allows users to connect J, K, or T thermocouples directly to
any of the Series SPPM panel meters. A standard K-type thermocouple
comes supplied with the unit. Power is provided via USB to the panel
meter or through the terminal blocks on the board. The built-in coldjunction compensation removes the effect of voltages on the system,
therefore giving a more accurate temperature measurement. Standard
features allow for the user to set high and low alarms, as well as change
the temperature unit output using Panel Pilot software.
INSTALLATION
The A-SPPM-TC shares the power with the SPPM it’s attached to. It can
be powered either using the terminal block on the board or via the USB
when connected to a PC. Connect the 14-way connector IDC socket of
the board to the SPPM. The thermocouple is wired to the TC+ (green)
and TC- (white) via the screw terminal block. The power source would
be wired to 0V and V+. Alarm outputs will be connected between ALM1
or ALM2 and the 0V terminal. For information on downloading the
customization software, refer to the SPPM instruction manual.
WIRING
Model A-SPPM-TC features six screw terminal connections.
0V
V+
ALM2
ALM1
TC+
TC-
SPECIFICATIONS
Probe Measurement Range:
K-type: -328 to 2462°F (-200 to 1350°C);
J-type: -328 to 2174°F (-200 to 1190°C);
T-type: -328 to 734°F (-200 to 390°C).
Temperature Limits: 14 to 104°F (-10 to 40°C).
Resolution: 1.0°F (0.5°C).
Power Requirements: Powered by USB port through SPPM panel
meter.
Accuracy: ±2.0°F (±1.0°C).
Weight: 0.9 oz (25.5 g).
Agency Approvals: RoHS.
SET UP MENUS
When setting up new configurations, select a meter style that denotes
Thermocouple input.
0V Ground connection for the SPPM and TC board.
V+ Alternative power supply input for the SPPM.
ALM1/ALM2 Open-collector outputs of the SPPM. See bulletin
Meter Style
PC-SPPM for details.
TC+ Positive connection for the thermocouple.
TC- Negative connection for the thermocouple.
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Phone: 219/879-8000 www.dwyer-inst.com
The color scheme can be customized for the background, numbers, and
display objects.
Next, the alarm set points, color of the visual alarms, and whether the
alarm is a high or low alarm can be set.
Color and Appearance
The type of thermocouple, engineering units and the scale range can be
programmed on the next screen.
Scaling
The labels and meter graphics can be selected in the next section.
High and Low Alarms
A custom splash screen can be selected to display upon power up.
Splash Screen
A configuration can be saved or immediately uploaded to a smart panel
meter.
Text Displayed
MAINTENANCE/REPAIR
Upon final installation of the Series A-SPPM-TC, no routine maintenance
is required. The Series A-SPPM-TC is not field serviceable and should
be returned if repair is needed. Field repair should not be attempted and
may void warranty.
WARRANTY/RETURN
Refer to “Terms and Conditions of Sale” in our catalog and on our
website. Contact customer service to receive a Return Goods
Authorization number before shipping the product back for repair. Be
sure to include a brief description of the problem plus any additional
application notes.
©Copyright 2013 Dwyer Instruments, Inc. Printed in U.S.A. 8/13 FR# R6-444133-00
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
Configuration Summary
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com