Dwyer 43000 User Manual

Bulletin B-34
(4) 6-32 HOLES
EQUALLY SPACED ON A
5-1/8 [130.18] B.C.
1/4 FEMALE NPT LOW PRESSURE
CONNECTION
(AIR OR GAS)
1/4 FEMALE NPT HIGH PRESSURE CONNECTION (AIR OR GAS)
1/4 FEMALE NPT HIGH PRESSURE CONNECTION (LIQUID)
3/4 [19.05] TYP
Ø [101.60]
FACE
5-1/2 [139.70] OD
MOUNTING RING
1/4 FEMALE
NPT LOW
PRESSURE
CONNECTION
(LIQUID)
Ø5
[127.00]
Ø4-47/64
[120.25]
5/8 [15.88]
5/8 [15.88]
PANEL MAX
3/16 [4.76]
3-7/8 [98.43]
5-1/8 [130.18]
7-5/16 [185.74]
8-9/16 [217.49]
4-3/8 [111.13]
HOUSING REMOVAL
3/4 CONDUIT
CONNECTION
Ø4-3/4
[120.65]
3-7/8 SQ
[98.43]
3-1/16 [77.79] TYP
Series 43000 Capsu-Photohelic®Pressure Switch/Gage
Specifications - Installation and Operating Instructions
Figure 1
The Capsu-Photohelic®Switch/Gage is a most versatile, precise pressure switch
combined with the Capsuhelic phototransistor actuated relays. Gage reading is unaffected by switch operation. Easy to adjust set points with knob controls. Applied pressure and switch set points are fully visible at all times. Deadband is one pointer width – less than 1% of full scale. Double-pole double-throw relays can be easily interlocked to provide variable deadband control. For positive, negative or differential pressures as low as 0 to .5 in w.c. and as high as 0 to 6000 psig full scale; set points as low as .01 in w.c. on a 5˝ scale unit.
PHOTOHELIC SENSING – HOW IT WORKS
In a typical control application, the Capsu-Photohelic between high and low pressure set-points. When pressure changes, reaching either set-point pressure, the beam from an LED to the limiting phototransistor will be cut off by the helix-driven light shield. The resulting signal change is electronically amplified to actuate its DPDT slave relay and switching occurs. Deadband between make and break is 1% of full scale or less – just enough to assure positive, chatter-free operation.
®
pressure gage. Available with one or two
®
switch/gage controls
SPECIFICATIONS GAGE SPECIFICATIONS Service: Compatible gases and liquids. Brass case option required for water
based liquids.
Wetted Materials: Consult factory. Accuracy: ±3% of FS at 70°F (21.1°C). ±2% on 43000S models; ±4% on 43215,
43220 and 43500.
Pressure Limits: -20 Hg to 500 psig (-0.677 to 34.5 bar). Temperature Limits: 20 to 120°F (-6.67 to 48.9°C). Low temperature option
available.
Process Connections: 1/4˝ female NPT. Size: 4˝ (101.6 mm) dial face, 5˝ (127 mm) OD x 9-3/16˝ (233.36 mm). Weight: 5 lb, 8 oz (2.49 kg). SWITCH SPECIFICATIONS Switch Type: Each setpoint has 2 form C relays (DPDT). Repeatability: ±1% of FS. Electrical Rating: 10 A @ 120 VAC, 6 A @ 240 VAC, 60 Hz res. 10 A @ 28
VDC.
Electrical Connections: Screw terminals. Power Requirements: 120 VAC, 50/60 Hz; 240 VAC & 24 VAC power optional. Mounting Orientation: Diaphragm in vertical position. Consult factory for other
position orientations.
Set Point Adjustment: Adjustable knobs on face.
Through Panel Mounting
Figure 2
*For convenience, this hole can be made with Model 730E, 120 MM chassis punch manufactured by Greenlee Tool Co. Contact your machine tool distributor. Not available from Dwyer Instruments.
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Phone: 219/879-8000 www.dwyer-inst.com
INSTALLATION
1. Location: All parts of the Capsu-Photohelic
®
pressure switch/gage
are ruggedly constructed and will stand a moderate amount of vibration, physical shock and handling. Normal care in handling and installation is all that is required. In cases where instrument panel vibration is severe, the panel should be mounted or the amplifier-relay unit mounted remotely on a more stable surface.
Select a location where the ambient temperature will not exceed 120°F. Pneumatic pressure sensing lines may be run any necessary distance. For example, 250 foot sensing lines will not affect accuracy but will damp the reading slightly. Do not restrict lines. If pulsating pressure or vibration causes excessive pointer oscillation or relay chatter, consult factory for additional damping means. See accessory Bulletin S-101 for fittings.
2. Position: The Capsu-Photohelic
®
may be mounted as an integral package
or the amplifier-load relay assembly and housing may be mounted remotely from
the indicating gage-phototransistor unit. Extension cords with 7 pin plugs and receptacles are available from Dwyer for interconnection of the two units.
All standard units are calibrated for use with the diaphragm and scale in a
vertical position. Special factory calibration is available for applications requiring inclined or horizontal positions. The exceptions are ranges under 5 in w.c. which are only available for vertical installation.
3. Mounting: The Capsu-Photohelic
®
is normally mounted before making electrical connections, as the electrical enclosure is independent of the mounting means and may be removed at any time.
A. Panel Mounting: Normal mounting is flush or through panel as shown in
Figure 2. Be sure to allow 4-3/8˝ extra space behind the unit for electrical enclosure removal. Make a single 4-13/16˝* diameter hole in the panel. Insert the entire Capsu-Photohelic
®
unit from the front, then slip on the mounting ring and snap ring from the rear. Seat the snap ring in its groove, back up the mounting ring against snap ring and tighten the four (4) 1-1/4˝ No. 6-32 clamp screws provided. If behind panel space is critical, the amplifier-relay unit can be mounted remotely. See the Remote-Relay Mounting Instructions for details.
(2) 1/4 DIA. HOLES FOR
BLOWOUT PASSAGE
7/8˝ DIA. HOLE
ø4-1/8
[103.58]
Ø4-3/8
[110.33]
42° TYP.
(2) HOLES
35° TYP.
(4) HOLES
(4) 3/16 DIA. HOLES
B: Hole Layout (Front)
Figure 3
C. Remote Relays Mounting: The amplifier – relay unit may be mounted remotely
as shown in Figure 4A. Use the hole layout as shown in Figure 4B for this option. Additional mounting information for special requirements is available from the factory.
B. Gage Mounting with Relay Package Remote: Where it is preferred to
install the amplifier-relay unit separate from the gage, (usually due to space limitations) the gage may either be panel mounted as shown in Figure 2 or surface mounted as in Figure 3A. For surface mounting, use the hole layout in Figure 3B.
CAUTION
When the gage is surface mounted, two 1/4˝ diameter holes
must be located as shown for blow-out protection. This assures that if the gage is overpressured, thus causing a failure, pressure will be safely vented out the back. Failure to keep these holes clear could result in personal injury and/or property damage since the excessive pressure could be forced into the front cover which would then blow off.
A: Surface Mounting
A: Remote Amplifier-Relay Unit
[108.74]
4-9/32
[108.74]
5
[127.00] SQ
B: Hole Layout
Figure 4
ø3/16
TYP 4 PLACES
4-9/32