dweLED CBWR1308, CBWR1307 Installation & Assembly

dweLED.com
Headquarters/Eastern Distribution Center
Western Distribution Center
dweLED retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Jan 2019 1

INSTALLATION INSTRUCTIONS

409 –LED PENDANT

PD-40901PD-40902
CAUTION: TO PREVENT ELECTRICAL SHOCK, ENSURE ELECTRICITY HAS BEEN TURNED OFF AT THE CIRCUIT BREAKER BEFORE BEGINNING.
- Read all instructions before installing.
- System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local
regulations.
- When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.
- Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or accessories designated for use by dweLED. Substitution of parts or accessories not designated for use with this product by dweLED could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are damaged or missing.
MAINTENANCE NOTE: Coastal conditions may cause mineral and residue build-up on the fixture. We recommend that customers in
coastal areas clean all external surfaces of the fixture once every two weeks with a wet cloth.
MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
- Lisez toutes les instructions avant l’installation.
- Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également
aux règlements locaux.
- Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec les pièces et/ou accessoires fournis pour être utilisés avec les produits dweLED. Remplacer des pièces ou accessoires non conçus pour ce produit dweLED pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
OTE D’ENTRETIEN:
N
Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous
recommendons aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec un chiffon humide.
HARDWARE
Phone (800) 526.2588 Fax (800) 526.2585
44 Harbor Park Drive Port Washington, NY 11050
1600 Distribution Ct
Lithia Springs, GA 30122
1750 Archibald Ave Ontario, CA 91761
dweLED.com
Headquarters/Eastern Distribution Center
Western Distribution Center
dweLED retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Jan 2019 2

INSTALLATION INSTRUCTIONS

Fig. 2 Wiring

409 –LED PENDANT

PD-40901PD-40902
PREPARATION
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) from the fixture.
4. Drill holes in the wall aligned with the key holes located on the back plate. Insert the plastic anchor (D).
5. Secure the mounting back plate to the junction box using the screws provided with the junction box. Fasten the back plate to the wall with the plastic anchors using the wood screws (C) provided.
NOTE: The side of the mounting plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 2)
6. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired.
a. Retract the wires close to the desired length within the
canopy before securing the fixture in place.
NOTE: Using the cable gripper to adjust more than 18” of wire length is not recommended. WARNING: Shortening the cables without professional help or electronic background is not advisable. Any modifications to the fixture will result in voiding the warranty of the product.
7. Connect the driver’s input/output wires with junction box wires as shown (Fig. 2). Make sure that all wire connectors (A) are secure. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
NOTE: This fixture features electronic low voltage (ELV) or 0-10V dimming capabilities. See notes below for specific dimming wiring information.
COMPLETING THE INSTALLATION
8. Secure the fixture to the mounting back plate using the mounting screw (B).
DIMMING WIRING INSTRUCTIONS (Fig. 3)
9. To utilize ELV dimming: use black (hot), white (neutral) and bare copper ground wires (ground).
10. To utilize 0-10V dimming: use purple (dim+), gray (dim-), black (hot), white (neutral) and bare copper ground wires (ground).
Phone (800) 526.2588 Fax (800) 526.2585
44 Harbor Park Drive Port Washington, NY 11050
1600 Distribution Ct
Lithia Springs, GA 30122
1750 Archibald Ave Ontario, CA 91761
dweLED.com
Headquarters/Eastern Distribution Center
Western Distribution Center
dweLED retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Jan 2019 1

INSTALLATION INSTRUCTIONS

409 –LED PENDANT

PD-40903
CAUTION: TO PREVENT ELECTRICAL SHOCK, ENSURE ELECTRICITY HAS BEEN TURNED OFF AT THE CIRCUIT BREAKER BEFORE BEGINNING.
- Read all instructions before installing.
- System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local
regulations.
- When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.
- Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or accessories designated for use by dweLED. Substitution of parts or accessories not designated for use with this product by dweLED could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are damaged or missing.
MAINTENANCE NOTE: Coastal conditions may cause mineral and residue build-up on the fixture. We recommend that customers in
coastal areas clean all external surfaces of the fixture once every two weeks with a wet cloth.
MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
- Lisez toutes les instructions avant l’installation.
- Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également
aux règlements locaux.
- Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec les pièces et/ou accessoires fournis pour être utilisés avec les produits dweLED. Remplacer des pièces ou accessoires non conçus pour ce produit dweLED pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
OTE D’ENTRETIEN:
N
recommendons aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec un chiffon humide.
Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous
HARDWARE
Phone (800) 526.2588 Fax (800) 526.2585
44 Harbor Park Drive Port Washington, NY 11050
1600 Distribution Ct
Lithia Springs, GA 30122
1750 Archibald Ave Ontario, CA 91761
dweLED.com
Headquarters/Eastern Distribution Center
Western Distribution Center
dweLED retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Jan 2019 2

INSTALLATION INSTRUCTIONS

Fig. 2 Wiring

409 –LED PENDANT

PD-40903
PREPARATION
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) from the fixture.
4. Drill holes in the wall aligned with the key holes located on the back plate. Insert the plastic anchor (D).
5. Secure the mounting back plate to the junction box using the screws provided with the junction box. Fasten the back plate to the wall with the plastic anchors using the wood screws (C) provided.
NOTE: The side of the mounting plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 2)
6. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired.
a. Retract the wires close to the desired length within the canopy
before securing the fixture in place. NOTE: Using the cable gripper to adjust more than 18” of wire length is not recommended. WARNING: Shortening the cables without professional help or electronic background is not advisable. Any modifications to the fixture will result in voiding the warranty of the product.
7. Hook the safety cord to the mounting back plate slot.
8. Connect the driver’s input/output wires with junction box wires as shown (Fig. 2). Make sure that all wire connectors (A) are secure. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
NOTE: This fixture features electronic low voltage (ELV) or 0-10V dimming capabilities. See notes below for specific dimming wiring information.
COMPLETING THE INSTALLATION
9. Secure the fixture to the mounting back plate using the mounting screw (B).
DIMMING WIRING INSTRUCTIONS (Fig. 3)
10. To utilize ELV dimming: use black (hot), white (neutral) and bare copper ground wires (ground).
11. To utilize 0-10V dimming: use purple (dim+), gray (dim-), black (hot), white (neutral) and bare copper ground wires (ground).
Phone (800) 526.2588 Fax (800) 526.2585