Advanced Functions
More advanced functions of your DVS system are accessed via the Menu button. These include:
• Fan speed • Heat Recovery mode
• Air warmer or Tempervent operation (if
tted)
• Automatic summer ventilation operation
(if tted)
• Heat Retention mode • Air transfer operation (if tted)
• Clock • Temperature history
• Replace lter • Diagnostics
Adjusting the fan speed
Your system has been congured so the airow and settings are individually calibrated to the
size of your home and will run at these settings automatically. However, you are able to easily
ne tune the fan speed to optimise condensation or climate control to better suit your needs.
Fan speed tuning allows you to adjust the fan speed to a level higher or lower than the pre-set
calibrated level (represented by the ‘0%’ setting).
To adjust the fan speed:
• Press the Menu button briey.
• Use the down arrow to select Fan settings and press OK.
• Use the down arrow to select Fan speed and press OK.
• Use the up or down arrow to change the fan speed (from -15% to +15%).
• Press OK to conrm the fan speed.
• Press the Menu button repeatedly until you return to the Main Screen.
Adjusting the Heat Retention Function
You can adjust the way your DVS system responds to situations where the roof air is colder
than the house temperature (winter nights). Heat retention comes into play when the system
senses that the room is warmer than the roof space, and slowing the system down will keep
the room temperature closer to the desired Set temperature. In the O position the Heat
retention function is o. At other levels of Heat retention the fan speed decreases in proportion
to the dierence between the roof temperature and the Set temperature. Selecting a higher
setting decreases the fan speed more quickly to a low level.
Note: A high Heat retention setting may compromise the ability of the DVS system to control
condensation.
• Press the Menu button briey.
• Use the down arrow to select Fan settings and press OK.
• Use the down arrow to select Heat retention and press OK.
• Use the up and down arrows to adjust the Heat retention tuning - from OFF
through to MAX.
• Note: The higher the setting (closer to MAX) the quicker the fan speed will
drop.
• Press OK to conrm your selection, then press the Menu button repeatedly
until you return to the Main Screen.
Page 5
Fan Speed
Allows you to ne tune
the fan speed to your
house and climate
+15%
0%
-15%
Heat Retention
Increasing this setting
reduces the fan speed
during winter months.
MAX
OFF
Adjusting the Heat Recovery Function
You can adjust the way your DVS system responds to situations where the roof air is hotter
than the house temperature (autumn, summer and spring days). Heat recovery comes into play
when the system senses that heat is available in the roof space that can be used to get closer
to the desired Set temp more quickly if the system speeds up. In the OFF position the Heat
recovery function is o. At other levels of Heat recovery, the fan speed increases in proportion
to the dierence between the roof temperature and the room temperature. Selecting a higher
setting increases the fan speed more quickly to a high level.
• Press the Menu button briey.
• Use the down arrow to select Fan settings and press OK.
• Use the down arrow to select Heat recovery and press OK.
• Use the up and down arrows to adjust the Heat recovery tuning - from OFF
through to MAX.
• Note: The higher the setting (closer to MAX) the quicker the fan speed will
increase.
• Press OK to conrm your selection, then press the Menu button repeatedly until
you return to the Main Screen.
Adjusting the Air warmer or Tempervent settings
Note: The Air warmer or Tempervent(s) will not function if the room set temperature has
already been achieved or the roof temperature is equal to or warmer than the room set
temperature.
The Air warmer or Tempervent is designed to pre-warm the air in the system before bringing it
into the house. It is designed to take the chill o incoming air during the cooler months, not to
warm your home like a central heating system. It can be set to work manually or automatically.
Note: This feature will only activate in the control system if it has been installed as an optional
extra.
• In Manual mode, you can set the Air warmer or Tempervent to be on for a
specied period of time, or o.
• In Automatic mode you can set the Air warmer or Tempervent to come on:
• at certain times (timer), or
• when the air in the roof falls below a specied temperature, or
• a combination of both (i.e. you can set the Air warmer or Tempervent to
come on when the air in the roof falls below the temperature you specify,
during the “On” part of the timer’s cycle).
Manual mode
To set the Air warmer or Tempervent to be on or o manually:
• Press the Menu button briey.
• Use the down arrow to select Air warmer or Tempervent and press OK.
• Use the down arrow to select Manual [0] and press OK.
• Use the up and down arrows to select the amount of time you want the Air
warmer or Tempervent to run for (30, 60, 90 or 120 minutes), or to turn it OFF.
• Press OK to conrm your selection, then press the Menu button repeatedly until
you return to the Main Screen.
Heat Recovery
Increasing this setting
raises the fan speed
on sunny cooler days.
MAX
OFF
Air Warmer
Manual [0]
Roof Temp
Timer
Temp & timer
Select the desired
operating mode. Only
one mode can be used
at any one time.
Manual Time Set
OFF
30min
60min
90min
120min
Air warmer runs for
one of the above times
and then turns off.