DVS AC01-001 Operating Instructions Manual

Page 1
Handheld Programmer
Operating Instructions
AC01-001
Step 1 : Basic operation
These instructions relate to the use of the Handheld Programmer only.
To turn on the programmer lift the rubber flap on the base, this will expose the switch and USB connection, move the switch in to the ON position, the unit will now power up. Refit the rubber flap (see Program­mer layout). Once powered on, the clock and date must be reset.
Using the left and right navigation buttons you can switch from menu to menu.
Once you have selected the menu you wish to change, use the up and down buttons to enter the part of the program you wish to change, when you have done this, use the left and right buttons to change the settings.
When you are happy with the settings, point the programmer at the sensor and press the send button (see Programmer layout). When the sensor is set a confirmation tick will appear on the screen.
IM PORTAN T: You must point the programmer away
from the sensor and leave for a minimum of 30 seconds before attempting to use, this allows the sensor to recalibrate. Attempting to use before this time may cause the sensor to lock up or false trigger.
9
T=000000 P=0000 R=00000
1
2
3
Step 2 : Data processing
To upload data on the programmer ensure the computer is on and Microsoft Excel is loaded. Turn on the Programmer using the isolation switch and connect the USB cable via the USB port. The cable will then need to be connected to the computer. The Programmer will then display a menu giving the option to ‘download’ or ‘charge’, press the ‘OK’ button to begin download, then ‘download’ will be displayed on screen. The data will then automatically upload into the Excel spread sheet and display ‘complete’.
IM PORTAN T: Microsoft Excel must be opened prior to download.
Step 3 : Charging
The Programmer requires a universal USB charging device. If being charged by computer connect the USB cable to the Programmer and then to the computer. The Programmer will then display a menu giving the option to ‘download’ or ‘charge’, follow prompts to ‘press any button’ to begin charging and display ‘charging’ on screen. Allow to trickle charge for a minimum of 8 hours.
IM PORTAN T: Charging for longer than 8 hours will not affect battery life or cause damage to the Programmer.
4
Key
1
Navigation button (x4) Switch cover
2
OK button Isolation switch
3
On/Off button USB / charging port
4
Receive button Screen legend:
5
Send button
5
The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste.
6
7 8
6
7
8
9
T= No. of Operations P= No. of Purges R= Total Run Time (mins)
Page 2
Step 4 : Menu options
NOTE : The default settings above can be restored at any time if needed via the
‘System Settings’ menu on the Programmer.
SETUP CLOCK
Day Month Year Hour Minutes Seconds
V2 TAP MENU
Run time Range Anti-vandal time Automatic Purge Purge run time
TAP MENU
Run Time Sensor Range Wave On/Off operation Anti Vandal Time Automatic Purge Purge Run Time Lock Outs
SHOwER MENU
Run Time Sensor Range Wave On/Off operation Anti Vandal Time Automatic Purge Purge Run Time Lock Outs
DEFAULT SETTINGS
(Once powered on, the clock and date must be reset).
2 Seconds 5 30 seconds OFF 1 Minute
2 Seconds 5 OFF 1 Minute OFF 1 Minute OFF
1 Minute 2 OFF Run+10s OFF 1 Minute OFF
OPTIONAL SETTINGS
1 - 31 1 - 12 Current year onwards 0 - 23 0 - 59 0 - 59
2, 5, 10, 20, 30, 40 & 60 Seconds 1-10 30, 60, 75, 90 Seconds & 2 Minutes OFF, 3, 6, 12, 24, 36 & 48 Hours 30 Seconds, 1, 2, 4 & 8 Minutes
2, 5, 10, 15, 20 & 30 Seconds 1 - 10 ON/OFF 30 Seconds, 1, 2, 4 & 8 Minutes OFF, 3, 6, 12, 24, 36 & 48 Hours 30 Seconds, 1, 2, 4 & 8 Minutes OFF, 4, 6, 8 & 10 Ops
30 Seconds, 1, 2, 3, 4 & 5 Minutes 1 - 3 ON/OFF Run+10s OFF, 3, 6, 12, 24, 36 & 48 Hours 30 Seconds, 1, 2, 4 & 8 Minutes OFF, 4, 6, 8 & 10 Ops
URINAL MENU
Pre-Flush Wait Pre-Flush Time Main Flush Time Sensor Range Automatic Purge Purge Run Time
BATH MENU
Run Time Sensor Range Wave On/Off operation Anti Vandal Time Automatic Purge Purge Run Time Lock Outs
AUTO FLUSH VALVE MENU
Range User Detect Time Dual Detect Time Flush Time(s) Walk Away Time Automatic Purge Purge Run Time Lock Outs
wAVE FLUSH VALVE MENU
Flush Type Flush Time(s) Range Automatic Purge Purge Run Time Lock Outs
1 Second OFF 2 Seconds 5 OFF 4 Seconds
2 Minutes 2 OFF Run+10s OFF 1 minute OFF
5 5 Seconds 20 Seconds 4 Seconds 2 Seconds OFF 4 Seconds OFF
Single 4 Seconds 2 OFF 4 Seconds OFF
1 & 2 Seconds OFF, 1, 2 & 3 Seconds 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6 & 6.5 Seconds 1 - 10 OFF, 6, 12, 24, 36, 48 & 72 Hours 2, 4, 6, 8 & 10 Seconds
1, 2, 3, 4, 8 & 10 Minutes 1 - 3 ON/OFF Run+10s OFF, 6, 12, 24, 36, 48 & 72 Hours 30 Seconds, 1, 2, 4 & 8 Minutes OFF, 2, 4, 6 & 8 Ops
1-10 1-10 Seconds 10, 12, 14, 16, 18, 20, 22, 24, 26 & 28 Seconds
2, 2.5, 3, 3.5, 4, 3/4.5, 3/5, 3.5/5.5, 4/6 & 6.5 Secs
1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5 & 5.5 Seconds OFF, 3, 6, 12, 24, 36, 48 & 72 Hours 2, 3, 3.5, 4, 4.5, 5, 5.5, 6 & 6.5 Seconds OFF, 2-10 Ops
Single or Dual 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6 & 6.5 Seconds 1-3 OFF, 3, 6, 12, 24, 36, 48 & 72 Hours 2, 3, 3.5, 4, 4.5, 5, 5.5, 6 & 6.5 Seconds OFF, 2-10 Ops
CHLORINATE MENU
Chlorination Time Abort and Reset
PP0 0 -4 68 011116
1 Minute
1, 2, 3, 4, 5, 10, 20 & 30 Minutes