1300 365 115 (Australia)
0800 729 389 (New Zealand)
Carefully remove all packaging and
transit protection from the heater before
installation. Dispose of the packaging
responsibly using re-cycling facilities
where they exist.
Specications and materials may change without notice
Effective for Sunpro gas boosted solar water heaters manufactured and sold after 1 April 2011.
H4096 4096 Rev. F
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Welcome To Dux Hot Water
Your decision to purchase a Dux Hot
Water system will reward you for many
years to come.
Since 1915, the Dux range has seen
continuous research and development,
resulting in many breakthroughs in the
efciency, reliability and longevity of hot
water systems.
Dux water heaters are manufactured
in Australia in a state-of-the-art facility,
using a Quality Endorsed Company
production system.
This is your assurance that you have
purchased the highest quality water
heater available, one that will provide
continuous hot water for all your needs
– safely, economically, and for many
years to come.
To be upfront about it, we want Dux to
be your brand of choice. So you can
depend on us to provide more than just
a hot water system.
Go with Dux and you’ll have a
dependable, economical, efcient hot
water system designed to perform well,
year after year. And that’s a promise.
You can rely on Dux products and
choose them with condence. We’ll
make sure you have the information, the
quality and the innovation you’re looking
for, including the latest energy-saving
alternatives. If you should ever have a
problem – and we’ll bet you won’t –
you’ll nd that we’re easy to get hold of,
friendly to talk to and quick to act. Our
service is all about providing anything
you need as soon as you need it.
H4096 4096 Rev. F
1
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
AS5601 – Gas Installation Code
Installation of the Tank
Installer’s Guide
Full and detailed installation instructions
are in the Installer’s Guide, included
inside the water heater’s carton.
Outdoor Tank Installation
The water heater must be installed
outdoors, with the minimum clearances
as shown in the gure below.
We recommend a plinth be installed
under the water heater where the
water heater is subjected to wet
conditions. Please refer to AS/NZS
3500.4, clause 5.5.3.
Minimum clearance around the windows
and doors must be maintained – refer to
AS 5601.
Location
The water heater should be located as
close as possible to the most frequently
used hot water outlet. Ensure that the
data label is clearly visible and that there
is adequate access for servicing the unit.
Note: All models are equipped with a
sacricial anode, accessible through the
top cover. Allow 50% of the height of
the water heater for clearance above to
replace the anode.
A properly drained overow tray must
be used where property damage could
occur from water spillage. (See AS/
NZS3500.4 for further details). Warranty
does not cover consequential damage
due to heater leakage.
Safety
This appliance is not intended for use
by persons (including children) with
reduced physical, sensory or mental
capabilities, or lack of experience and
knowledge, unless they have been given
supervision or instruction concerning
use of the appliance by a person
responsible for their safety.
Children and animals should be
supervised to ensure that they do not
interfere with the appliance.
B
A
C
A = 500mm B=300mm C=50mm min
For further details, refer to
2
H4096 4096 Rev. F
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Installation of the Tank
Installation of the Tank
Frost Protection
The areas in gray in the map below may
be vulnerable to frost. Solar hot water
heaters installed in these areas require
an approved antifrost protection device
to maximise system performance.
Note: The Gas Boosted Solar water
heater already has an in-built frost
protection device, so no further antifrost
protection is required.
Model Numbers
Below is a list of model numbers and
their descriptions:
Model No.Description
DN15DS315 Litre, 45 MJ/h, Natural Gas
DL15DS315 Litre, 45 MJ/h, LPG
DN15CS250 Litre, 45 MJ/h, Natural Gas
DL15CS250 Litre, 45 MJ/h, LPG
H4096 4096 Rev. F
Auckland
Wellington
Christchurch
3
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Plumbing Connections
Installation Requirements
This water heater must be installed
by a licensed tradesperson, and in
accordance with:
• AS/NZS3500.4 “National Plumbing
and Drainage Code Hot Water
Supply Systems – Acceptable
Solutions”.
• AS5601/AG601 “Gas Installations”
• Local authority regulations.
• Outside Australia and New Zealand,
please refer to local plumbing and
building codes and regulations.
• Notice to Victorian customers
from the Victorian Plumbing
Industry Commission – this water
heater must be installed by a
licensed person as required by the
Victorian Building Act (1993). Only
a licensed person will give you a
compliance certicate, showing
that the work complies with all
the relevant Standards and only a
licensed person will have insurance
protecting their workmanship for 6
years.
Water Supply Pressure
This water heater is designed for direct
connection to water supply pressures of
no greater than:
800kPa
Where the mains pressure can exceed
or uctuate beyond the pressure
shown above, a pressure limiting
device (complying with AS1357) must
be tted in the cold water inlet supply.
This device must be installed after
the isolating valve and set below the
pressure shown above. Note during
periods of lower demand water pressure
may increase.
Pool Heating
This water heater must not be used for
pool heating.
4
H4096 4096 Rev. F
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Plumbing Connections
Pressure & Temperature Relief
Valve
The Pressure & Temperature Relief (PTR)
Valve is supplied loose with the water
heater. The valve rating is:
1000kPa
The specications and part numbers of
the PTR Valve provided are:
Part No: H0443
Description: PT VALVE ½" – HT55
1000kPa
The PTR valve must be installed directly
into the top socket marked “RELIEF
VALVE”. The drain line from this valve
must run in a continuously downward
direction in a frost-free ambient position
with the discharge end left open to
atmosphere permanently.
The PTR Valve is not intended to enable
connection of the water heater to
supplementary energy sources such as
solar panels or slow combustion stoves
(refer AS/NZS 3500.4 for guidance on
these types of installations).
Warning: We recommend that you
open the PTR valve at least once every
six (6) months. Failure to do this may
result in problems with the water heater.
The PTR Valve must not be tampered
with or removed. The water heater must
not be operated unless this valve is
tted and in working order.
The PTR Valve should be checked for
adequate performance or replaced at
intervals not exceeding 5 years, or less
in areas where local regulations apply.
Important: The PTR Valve and its
drain outlet pipe must not be sealed or
blocked. It is normal for the PTR valve
to leak a small amount of water during
heating cycles.
Open the PTR Valve for approximately
10 seconds by lifting the lever on the
valve to ensure water is relieved to waste
through the relief drain pipe. Lower lever
gently and check that it closes correctly.
H4096 4096 Rev. F
5
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Connection
Valve
Cold Water
Inlet
Expansion
Isolating Valve
Plumbing Connections
Cold Water Connection
It is mandatory to t the following items
between the supply main and the
RP¾"/20mm socket in the water heater.
• an isolating valve
• a non return valve
• a line strainer
• a union
All ttings must be approved by the
relevant Authority and in accordance to
the plumbing code.
(Spindle Vertical)
Line
Strainer
Note: a combined isolating valve/nonreturn valve/line strainer may be used.
Expansion valve only required where local
regulations demand.
Valve
Union
Non-return
Note for S.A. and W.A.: It is a state
requirement that a pressure relief valve
be tted on the cold water supply line
between the non return valve and the
water heater.
Hot Water Connection
The hot water line should be connected
to the “OUTLET” socket on the tank.
Insulation of Pipes
All hot water pipes must be insulated
with UV stabilized insulation suitable
for solar working temperatures, e.g.
Armaex Insulation.
Building Flow & Return
Never install a building circulated ow
and return line to the inlet connection
of a Dux (Electric solar or Gas solar
hot water heater) or (Heat Pump water
heater)
The solar water heater is not designed
to be installed on a circulated ow
and return line due to loss of thermal
efciency. Extensive pipe work will
cause efciency losses gained from
solar energy and will increase energy
consumption.
If a ow and return line is required, we
recommend that you install a backup
storage or continuous ow water heater
on the ow and return line and a time
control the building circulation loop to
help reduce energy usage.
6
H4096 4096 Rev. F
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Plumbing Connections
Temperature Protection
All solar water heaters have the ability
to produce hot water very quickly.
To reduce the risk of scald injury, it is
mandatory under the requirements of
Australian Standard AS/NZS3500.4 that
a suitably approved temperature control
device, such as a tempering valve, be
tted to the hot water supply to outlets
used primarily for personal hygiene.
Note: This water heater is supplied
with a tempering valve. Install the
valve according to the manufacturer’s
recommendations. Any adustments to
the valve should be made according to
the manufacturer’s recommendations.
The tempering valve should be checked
at regular intervals to ensure its
operation and settings remain correct.
H4096 4096 Rev. F
7
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
FrontRHSLHS
T ank Alignment
Specifications
Detail G
Wall
Water
Heater
Hot
Water
Outlet
Cold
Water
Inlet
Model
Number
A B
Approximate
Weight Empty
(kg)
See
Detail G
D
E
C
Dimensions
(mm)
ABCDEF
Solar drain.
Plumb to
waste.
To solar
collector
Gas inlet
Return from
solar
collectors
F
See
Detail G
Storage
Capacity
(L)
DN15CS, DL15CS9814441231215750617648259
DN15DS, DL15DS112175415412157506171013324
Note: Minor changes to specifications and materials may occur without notice. While these will not affect the
safety, reliability or performance of your Dux unit, they could impact on the installation procedures explained in
this manual – check with Dux on 1300 365 115 if you are uncertain about any aspect of installing this product.
8
H4096 4096 Rev. F
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.