Dux Sunpro DN15DS, Sunpro DL15DS, Sunpro DL15CS, Sunpro DN15CS Installation And Owner's Manual

Owner’s Manual
Pre Boosted Gas Solar Water Heater MP15
Models: DN15DS
DL15DS DN15CS DL15CS
Installation Details
Owner’s Information
Warranty
For advice, repairs and service, call:
1300 365 115 (Australia) 0800 729 389 (New Zealand)
Carefully remove all packaging and transit protection from the heater before installation. Dispose of the packaging responsibly using re-cycling facilities where they exist.
Specications and materials may change without notice Effective for Sunpro gas boosted solar water heaters manufactured and sold after 1 April 2011.
H4096 4096 Rev. F
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Contents
Welcome To Dux Hot Water 1
Installation of the Tank 2
Plumbing Connections 4
Specications 7
System Components 8
Installation of Collectors 10
Plumbing Connections to Collectors 13
Gas Connection 15
Electrical Connections 16
Hotlogic Connections 17
Owner’s Information 18
System Maintenance 22
Troubleshooting 23
Warranty 25
Other Information 28
© Dux Manufacturing Limited 2012. All rights reserved.
H4096 4096 Rev. F
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Welcome To Dux Hot Water
Your decision to purchase a Dux Hot Water system will reward you for many years to come.
Since 1915, the Dux range has seen continuous research and development, resulting in many breakthroughs in the efciency, reliability and longevity of hot water systems.
Dux water heaters are manufactured in Australia in a state-of-the-art facility, using a Quality Endorsed Company production system.
This is your assurance that you have purchased the highest quality water heater available, one that will provide continuous hot water for all your needs – safely, economically, and for many years to come.
To be upfront about it, we want Dux to be your brand of choice. So you can depend on us to provide more than just a hot water system.
Go with Dux and you’ll have a dependable, economical, efcient hot water system designed to perform well, year after year. And that’s a promise.
You can rely on Dux products and choose them with condence. We’ll make sure you have the information, the quality and the innovation you’re looking for, including the latest energy-saving alternatives. If you should ever have a problem – and we’ll bet you won’t – you’ll nd that we’re easy to get hold of, friendly to talk to and quick to act. Our service is all about providing anything you need as soon as you need it.
H4096 4096 Rev. F
1
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
AS5601 – Gas Installation Code
Installation of the Tank
Installer’s Guide
Full and detailed installation instructions are in the Installer’s Guide, included inside the water heater’s carton.
Outdoor Tank Installation
The water heater must be installed outdoors, with the minimum clearances as shown in the gure below.
We recommend a plinth be installed under the water heater where the water heater is subjected to wet conditions. Please refer to AS/NZS
3500.4, clause 5.5.3.
Minimum clearance around the windows and doors must be maintained – refer to AS 5601.
Location
The water heater should be located as close as possible to the most frequently used hot water outlet. Ensure that the data label is clearly visible and that there is adequate access for servicing the unit.
Note: All models are equipped with a sacricial anode, accessible through the top cover. Allow 50% of the height of the water heater for clearance above to replace the anode.
A properly drained overow tray must be used where property damage could occur from water spillage. (See AS/ NZS3500.4 for further details). Warranty does not cover consequential damage due to heater leakage.
Safety
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children and animals should be supervised to ensure that they do not interfere with the appliance.
B
A
C
A = 500mm B=300mm C=50mm min
For further details, refer to
2
H4096 4096 Rev. F
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Installation of the Tank
Installation of the Tank
Frost Protection
The areas in gray in the map below may be vulnerable to frost. Solar hot water heaters installed in these areas require an approved antifrost protection device to maximise system performance.
Note: The Gas Boosted Solar water heater already has an in-built frost protection device, so no further antifrost protection is required.
Model Numbers
Below is a list of model numbers and their descriptions:
Model No. Description
DN15DS 315 Litre, 45 MJ/h, Natural Gas
DL15DS 315 Litre, 45 MJ/h, LPG
DN15CS 250 Litre, 45 MJ/h, Natural Gas
DL15CS 250 Litre, 45 MJ/h, LPG
H4096 4096 Rev. F
Auckland
Wellington
Christchurch
3
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Plumbing Connections
Installation Requirements
This water heater must be installed by a licensed tradesperson, and in accordance with:
AS/NZS3500.4 “National Plumbing and Drainage Code Hot Water Supply Systems – Acceptable Solutions”.
AS5601/AG601 “Gas Installations”
Local authority regulations.
Outside Australia and New Zealand, please refer to local plumbing and building codes and regulations.
Notice to Victorian customers from the Victorian Plumbing Industry Commission – this water heater must be installed by a licensed person as required by the Victorian Building Act (1993). Only a licensed person will give you a compliance certicate, showing that the work complies with all the relevant Standards and only a licensed person will have insurance protecting their workmanship for 6 years.
Water Supply Pressure
This water heater is designed for direct connection to water supply pressures of no greater than:
800kPa
Where the mains pressure can exceed or uctuate beyond the pressure shown above, a pressure limiting device (complying with AS1357) must be tted in the cold water inlet supply. This device must be installed after the isolating valve and set below the pressure shown above. Note during periods of lower demand water pressure may increase.
Pool Heating
This water heater must not be used for pool heating.
4
H4096 4096 Rev. F
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Plumbing Connections
Pressure & Temperature Relief Valve
The Pressure & Temperature Relief (PTR) Valve is supplied loose with the water heater. The valve rating is:
1000kPa
The specications and part numbers of the PTR Valve provided are:
Part No: H0443
Description: PT VALVE ½" – HT55 1000kPa
The PTR valve must be installed directly into the top socket marked “RELIEF VALVE”. The drain line from this valve must run in a continuously downward direction in a frost-free ambient position with the discharge end left open to atmosphere permanently.
The PTR Valve is not intended to enable connection of the water heater to supplementary energy sources such as solar panels or slow combustion stoves (refer AS/NZS 3500.4 for guidance on these types of installations).
Warning: We recommend that you open the PTR valve at least once every six (6) months. Failure to do this may result in problems with the water heater.
The PTR Valve must not be tampered with or removed. The water heater must not be operated unless this valve is tted and in working order.
The PTR Valve should be checked for adequate performance or replaced at intervals not exceeding 5 years, or less in areas where local regulations apply.
Important: The PTR Valve and its drain outlet pipe must not be sealed or blocked. It is normal for the PTR valve to leak a small amount of water during heating cycles.
Open the PTR Valve for approximately 10 seconds by lifting the lever on the valve to ensure water is relieved to waste through the relief drain pipe. Lower lever gently and check that it closes correctly.
H4096 4096 Rev. F
5
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Connection
Valve
Cold Water Inlet
Expansion
Isolating Valve
Plumbing Connections
Cold Water Connection
It is mandatory to t the following items between the supply main and the RP¾"/20mm socket in the water heater.
an isolating valve
a non return valve
a line strainer
a union
All ttings must be approved by the relevant Authority and in accordance to the plumbing code.
(Spindle Vertical)
Line Strainer
Note: a combined isolating valve/non­return valve/line strainer may be used. Expansion valve only required where local regulations demand.
Valve
Union
Non-return
Note for S.A. and W.A.: It is a state requirement that a pressure relief valve be tted on the cold water supply line between the non return valve and the water heater.
Hot Water Connection
The hot water line should be connected to the “OUTLET” socket on the tank.
Insulation of Pipes
All hot water pipes must be insulated with UV stabilized insulation suitable for solar working temperatures, e.g. Armaex Insulation.
Building Flow & Return
Never install a building circulated ow and return line to the inlet connection of a Dux (Electric solar or Gas solar hot water heater) or (Heat Pump water heater)
The solar water heater is not designed to be installed on a circulated ow and return line due to loss of thermal efciency. Extensive pipe work will cause efciency losses gained from solar energy and will increase energy consumption.
If a ow and return line is required, we recommend that you install a backup storage or continuous ow water heater on the ow and return line and a time control the building circulation loop to help reduce energy usage.
6
H4096 4096 Rev. F
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Plumbing Connections
Temperature Protection
All solar water heaters have the ability to produce hot water very quickly. To reduce the risk of scald injury, it is mandatory under the requirements of Australian Standard AS/NZS3500.4 that a suitably approved temperature control device, such as a tempering valve, be tted to the hot water supply to outlets used primarily for personal hygiene.
Note: This water heater is supplied with a tempering valve. Install the valve according to the manufacturer’s recommendations. Any adustments to the valve should be made according to the manufacturer’s recommendations.
The tempering valve should be checked at regular intervals to ensure its operation and settings remain correct.
H4096 4096 Rev. F
7
Owner’s Manual – Pre Boosted Gas Solar Water Heater MP15
Front RHSLHS
T ank Alignment
Specifications
Detail G
Wall
Water Heater
Hot Water Outlet
Cold Water Inlet
Model
Number
A B
Approximate
Weight Empty
(kg)
See Detail G
D
E
C
Dimensions
(mm)
A B C D E F
Solar drain. Plumb to waste.
To solar collector
Gas inlet
Return from solar collectors
F
See Detail G
Storage
Capacity
(L)
DN15CS, DL15CS 98 1444 1231 215 750 617 648 259
DN15DS, DL15DS 112 1754 1541 215 750 617 1013 324
Note: Minor changes to specifications and materials may occur without notice. While these will not affect the safety, reliability or performance of your Dux unit, they could impact on the installation procedures explained in this manual – check with Dux on 1300 365 115 if you are uncertain about any aspect of installing this product.
8
H4096 4096 Rev. F