![](/html/fd/fd67/fd67785b796948dadbae95b47f5d534cdb2bf4f2f563179e8a0f37eb4d44abb0/bg1.png)
Installation Instructions
DuraTech 5" - 24"
Chimney Shroud
DuraTech Shroud
![](/html/fd/fd67/fd67785b796948dadbae95b47f5d534cdb2bf4f2f563179e8a0f37eb4d44abb0/bg2.png)
A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE
TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO
COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE
THAT THIS CHIMNEY BE INSTALLED ONLY IN
ACCORDANCE WITH THESE INSTRUCTIONS.
NOTE:
Read through all these instructions
before beginning your installation. Failure
toinstall the chimney as described in these
instructions will void the manufacturer’s
warranty and may have an effect on your
homeowner insurance and UL listing
status. Refer to the DuraTech Chimney
Installation Instructions for complete details
on installing the DuraTech Chimney system.
Keep these instructions for future use.
Dear Customer, Installer, or End User:
We welcome any comments regarding matters
pertaining to our DuraVent products.
We welcome any ideas, input or complaints
and I’ll make sure that someone responds
directly back to you.
Send your emails to:
president@duravent.com
If you are searching for tech support or product
information, please phone us at 800-835-4429.
Or email us at:
techsupport@duravent.com
APPLICATION AND LISTING
As specied in these instructions, Shrouds are
approved for use with DuraTech Chimney
(5”-24” diameter). A Shroud built and installed
in compliance with these instructions is UL
listed for use with DuraTech chimney (listing
number MH7399).
INSTALLATION NOTES
Practice good workmanship. Exercise
extreme caution when working on roofs. Be
sure to wear appropriate safety gear and
clothing as needed. Refer to the DuraTech
Chimney Installation Instructions for further
safety details.
MH7399
![](/html/fd/fd67/fd67785b796948dadbae95b47f5d534cdb2bf4f2f563179e8a0f37eb4d44abb0/bg3.png)
SHROUD REQUIREMENTS
Shrouds can either be eld-fabricated or
factory-fabricated, but they must meet the
requirements as specied in these instructions.
Shrouds must be constructed of a minimum
24 gauge (.024”) stainless steel, aluminized
steel, galvanized steel, or copper. Other
materials may also be used, such as brick,
mortar, stucco, stone, etc., provided they
are completely non-combustible. Check with
your local building code authorities for any
additional shroud requirements. Shrouds
must be able to be removed to allow chimney
access to properly clean the chimney.
DuraTech installations which include the use
of a shroud must comply with the following
requirements (Figure 1):
ALLOW A 1-INCH AIR GAP BETWEEN STORM
COLLAR AND CHASE TOP FLASHING
1/2” AIR SPACE ESTABLISHED
BY SPACERS
▪ DuraTech chimney must maintain at least 2”
clearance from combustible materials.
▪ The chase enclosure must be ventilated.
▪ The Chase Top Flashing or eld-fabricated
chase pan must be used. Fieldfabricated
chase pans are acceptable if they meet these
requirements:
▪ Material must be 24 gauge (.024”)
Galvanized steel or equivalent.
▪ Chase pan must have opening 3”
larger than outside diameter of
chimney pipe with at least a 1/2”
upturned ange/collar.
▪ Chase pan must overhang chase
by 1/2” per side for proper air ow.
▪ Chase pan must have a 1” down
urned outside edge (weather
protection).
CHIMNEY CAP
STORM COLLAR
5”-16” DIAMETER
CHIMNEY MUST
EXTEND AT LEAST 3-
INCHES, 18”-24” MUST
EXTEND AT LEAST 6-
INCHES ABOVE CHASE
TOP FLASHING.
1/2-INCH
OVERHA NG
DURATECH
CHIMNEY
MAINTAIN 2-INCH
CLEARANCE BETWEEN
DURATECH CHIMNEY AND
CHASE ENCLOSURE
Figure 1
CHASE TOP
FLASHING OR
CHASE PAN
1/2-INCH
FIELD-FABRICATED
SPACERS FOR CHASE
TOP FLASHING
3