Instruction Manual
This is a safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid injury or death
To avoid personal injury keep hands and feet away from work area during operation
Do NOT handle pressurised hoses. Escaping oil under pressure can penetrate the skin
causing serious injury. If oil is injected under the skin, see a doctor immediately
Stay clear of loads supported by hydraulics. A cylinder, when used as a load lifting
device, should never be used as a load holding device. After the load has been raised
or lowered, it must always be supported mechanically
1.0 Product Information
DURAPAC – 035 Series Auto 2 Speed Power Units are engineered to meet Industrial Standards for
Performance and Safety. The SPES3502AR model delivers 2.0 Lpm up to 10 bar and 0.2 Lpm up to
700 bar pressure on single acting cylinders and tools. The power unit has an internal ‘pop off’ valve
to indicate full pressure and remote pendant to actuate Advance/Retract functions. The power unit
is driven by a 0.35 kW, 230 Volt, 50/60 Hz single phase electric motor and may be used at any angle
due to the fully enclosed rubber lined reservoir. The power unit is lightweight and easily portable
using the shoulder strap and handle.
Special skill, knowledge and training may be required for a specific task and the product may not be
suitable for all jobs. The user must ultimately make the decision regarding suitability of the product
for any given task and assume the responsibility of safety for all in the work area. Contact a Durapac
representative if you are unsure of your power unit’s suitability for a particular application.
2.0 Receiving Instructions
It is recommended prior to use that an inspection be done by qualified personnel and that any
missing or damaged parts, decals, warning/safety labels or signs are replaced with Durapac
authorised replacement parts only. Any power unit that appears to be damaged in any way, is worn,
leaking or operates abnormally should be removed from service immediately until such time as
repairs can be made. Any power unit that has been or suspected to have been subject to a shock
load should be removed from service immediately until inspected by a Durapac authorised service
centre. Owners and operators of this equipment should be aware that the use and subsequent
repair of this equipment may require specialised training and knowledge.
3.0 Safety
Save these instructions. For your safety, read and understand the information contained within. The
owner and operator should have an understanding of this product and safe operating procedures
before attempting to use this product. Instructions and safety information should be conveyed in the
operator's native language before use of this product is authorised. Make certain that the operator
thoroughly understands the inherent dangers associated with the use and misuse of the product. If
any doubt exists as to the safe and proper use of this product as outlined in this factory authorised
manual, remove from service immediately.
SPES3502AR Electric PU - V1.0 www.durapac.com Page 2 of 12
![](/html/b2/b24c/b24c286b1b3ac3ffd2f28b1b85fef07cdd1b407ded08fe2d0adbf6cb68b6fb6a/bg3.png)
Instruction Manual
The system operating pressure must not exceed the pressure rating of the lowest
rated component in the system. Install pressure gauges in the system to monitor
operating pressure. It is your window to what is happening in the system
Always wear appropriate personal protective equipment (PPE) when operating
hydraulic equipment. The operator must take precaution against injury due to failure
of the tool or work piece(s)
Do NOT hold or stand directly in line with any hydraulic connections while pressurising
Do NOT attempt to disconnect hydraulic connections under pressure. Release all line
pressure before disconnecting hoses
All personnel must be clear before lowering load or depressurising the system
Do NOT attempt to lift a load weighing more than the capacity of the cylinder
If at any stage, the safety related decals become hard to read, these must be replaced
Minimum age of the operator must be 18 years. The operator must have read and
understood all instructions, safety issues, cautions and warnings before starting to
operate the equipment. The operator is responsible for this activity towards other
persons
Do NOT lift hydraulic equipment by the hoses or couplers. Use the carrying handle or
other means of safe transport
Hydraulic equipment must only be serviced by a qualified hydraulic technician. For
repair service, contact the Durapac authorised service centre in your area. To protect
your warranty, use only high quality hydraulic oil
KEEP HYDRAULIC EQUIPMENT AWAY FROM FLAMES AND HEAT. Hydraulic fluid can
ignite and burn. Excessive heat will soften packings and seals, resulting in fluid leaks.
Heat also weakens hose materials and packings. For optimum performance do not
expose equipment to temperatures of 55°C (131°F) or higher. Protect all equipment
from weld spatter
No alteration should be made to this device
3.1 Hydraulic Power Units
Do use a gauge or other load measuring instrument to verify load
Do NOT exceed the rated capacity of the power unit or any equipment in the system.
Burst hazard exists if connection pressure exceeds rated pressure
Do NOT operate the system with bent or damaged couplers or damaged threads
Do NOT subject the power unit and its components to shock loads
Use only Durapac approved accessories and components
SPES3502AR Electric PU - V1.0 www.durapac.com Page 3 of 12
![](/html/b2/b24c/b24c286b1b3ac3ffd2f28b1b85fef07cdd1b407ded08fe2d0adbf6cb68b6fb6a/bg4.png)
Instruction Manual
SPES3502AR 0.35 230 50/60 4.5 1.6 700 2 0.2
Advance/Retract. Pop Off
valve indicates full pressure.
Maximum
Pressure
Rating
(bar)
Remote Pendant Function
2.4 mtr
Do NOT connect to an application which can return more oil to the reservoir than the
power unit reservoir can hold
Do NOT connect power unit to a hydraulic system that is powered by another pump
3.2 Hydraulic Hoses & Fluid Transmission Lines
Avoid short runs of straight line tubing. Straight line runs do not provide for expansion
and contraction due to pressure and/or temperature changes
Reduce stress in tube lines. Long tubing runs should be supported by brackets or clips.
Before operating the power unit, connections should be tightened securely and leakfree. Over tightening can cause premature thread failure or high pressure fittings to
burst
Should a hydraulic hose ever rupture, burst or need to be disconnected, immediately
shut off the power unit and release all pressure. Never attempt to grasp a leaking
pressurised hose with your hands. The force of escaping hydraulic fluid can inflict
injury
Do NOT subject the hose to potential hazard such as fire, sharp objects, extreme heat
or cold or heavy impact
Do NOT allow the hose to kink, twist, curl, crush, cut or bend so tightly that the fluid
flow within the hose is blocked or reduced. Periodically inspect the hose for wear
Hose material and coupler seals must be compatible with the hydraulic fluid used.
Hoses also must not come in contact with corrosive materials such as battery acid,
creosote-impregnated objects and wet paint. Never paint a coupler or hose
FAILURE TO HEED THESE WARNINGS MAY RESULT IN PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.
4.0 Installation
IMPORTANT: Always secure threaded port connections with high grade, non-hardening pipe
thread sealant. Teflon tape can be used if only one layer of tape is used and it is applied
carefully, two threads back, to prevent the tape from being introduced into hydraulic system,
which could cause jamming of precision-fit parts
To avoid power loss between the electrical outlet and the power unit motor, use the shortest
possible extension cord
4.1 Familiarise yourself with the specifications and illustrations in this owner’s manual. Know
your power unit, its limitations and how it operates before attempting to use. Refer to
the specification chart below or if in doubt, contact a Durapac representative.
SPES3502AR Electric PU - V1.0 www.durapac.com Page 4 of 12