Durapac DPA-18 Instruction Manual

Maximum Operating Pressure – 700 bar
Instruction Manual
Reciprocating Air Hydraulic Power Unit Model – DPA-18
ABSOLUTE EQUI P MENT PTY LTD 2 /186 Granite Street, GEEBUNG QL D 4034 A u stralia
sale s @abs o l utee q uipme nt.co m .au – P hone : +61 7 386 5 400 6 – Fax: + 61 7 3102 628 8
This is a safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid injury or death
DANGER:
To avoid personal injury keep hands and feet away from work area during operation
Do NOT handle pressurised hoses. Escaping oil under pressure can penetrate the skin
1.0 Product Information
DURAPAC – Reciprocating Air Hydraulic Power Units are engineered to meet Industrial Standards for Performance and Safety. The DPA-18 model’s unique hydraulic circuit allows the quick displacement of hydraulic fluid under no load conditions and easy pumping in loaded conditions. These air actuated power units supply compressed hydraulic fluid to compatible applications i.e. cylinder, presses, spreaders, compactors and crimping machines, anywhere that 700 bar of fluid pressure is needed.
1.8 L usable oil reservoir 3 position treadle for adv/hold/retract functions Treadle may be operated by hand or foot for greater versatility Release detent function enhances productivity Convenient carry handle included Recommended air pressure range 4-12 bar
Special skill, knowledge and training may be required for a specific task and the product may not be suitable for all jobs. The user must ultimately make the decision regarding suitability of the product for any given task and assume the responsibility of safety for all in the work area. Contact a Durapac representative if you are unsure of your power unit’s suitability for a particular application.
2.0 Receiving Instructions
It is recommended prior to use that an inspection be done by qualified personnel and that any missing or damaged parts, decals, warning/safety labels or signs are replaced with Durapac authorised replacement parts only. Any power unit that appears to be damaged in any way, is worn, leaking or operates abnormally should be removed from service immediately until such time as repairs can be made. Any power unit that has been or suspected to have been subject to a shock load should be removed from service immediately until inspected by a Durapac authorised service centre. Owners and operators of this equipment should be aware that the use and subsequent repair of this equipment may require specialised training and knowledge.
3.0 Safety
Save these instructions. For your safety, read and understand the information contained within. The owner and operator should have an understanding of this product and safe operating procedures before attempting to use this product. Instructions and safety information should be conveyed in the operator's native language before use of this product is authorised. Make certain that the operator thoroughly understands the inherent dangers associated with the use and misuse of the product. If any doubt exists as to the safe and proper use of this product as outlined in this factory authorised manual, remove from service immediately.
DPA-18 Air Hyd. Power Unit - V1.0 www.durapac.com Page 2 of 11
causing serious injury. If oil is injected under the skin, see a doctor immediately
Stay clear of loads supported by hydraulics. A cylinder, when used as a load lifting
device, should never be used as a load holding device. After the load has been raised or lowered, it must always be supported mechanically
WARNING:
The system operating pressure must not exceed the pressure rating of the lowest
rated component in the system. Install pressure gauges in the system to monitor operating pressure. It is your window to what is happening in the system
Always wear appropriate personal protective equipment (PPE) when operating
hydraulic equipment. The operator must take precaution against injury due to failure of the tool or work piece(s)
Do NOT hold or stand directly in line with any hydraulic connections while pressurising
Do NOT attempt to disconnect hydraulic connections under pressure. Release all line
pressure before disconnecting hoses
All personnel must be clear before lowering load or depressurising the system
Do NOT attempt to lift a load weighing more than the capacity of the cylinder
IMPORTANT:
If at any stage, the safety related decals become hard to read, these must be replaced
Minimum age of the operator must be 18 years. The operator must have read and
understood all instructions, safety issues, cautions and warnings before starting to operate the equipment. The operator is responsible for this activity towards other persons
Do NOT lift hydraulic equipment by the hoses or couplers. Use the carrying handle or
other means of safe transport
Hydraulic equipment must only be serviced by a qualified hydraulic technician. For
repair service, contact the Durapac authorised service centre in your area. To protect your warranty, use only high quality hydraulic oil
CAUTION:
KEEP HYDRAULIC EQUIPMENT AWAY FROM FLAMES AND HEAT. Hydraulic fluid can
ignite and burn. Excessive heat will soften packings and seals, resulting in fluid leaks. Heat also weakens hose materials and packings. For optimum performance do not expose equipment to temperatures of 65°C (150°F) or higher. Protect all equipment from weld spatter
No alteration should be made to this device
3.1 Hydraulic Power Units
Do use a gauge or other load measuring instrument to verify load Do NOT exceed the rated capacity of the power unit or any equipment in the system.
Burst hazard exists if connection pressure exceeds rated pressure
Do NOT operate the system with bent or damaged couplers or damaged threads
DPA-18 Air Hyd. Power Unit - V1.0 www.durapac.com Page 3 of 11
IMPORTANT:
Always secure threaded port connections with high grade, non-hardening pipe thread
sealant. Teflon tape can be used if only one layer of tape is used and it is applied carefully, two threads back, to prevent the tape from being introduced into hydraulic system, which could cause jamming of precision-fit parts
To extend the life of your power unit, the air compressor should have a filter, regulator
and lubricator system that will provide clean, lubricated air to the power unit. Contact a Durapac representative for the necessary accessories
Do NOT subject the power unit and its components to shock loads Use only Durapac approved accessories and components Do NOT connect to an application which can return more oil to the reservoir than the
power unit reservoir can hold
Do NOT connect the power unit to a hydraulic system that is powered by another
pump
3.2 Hydraulic Hoses & Fluid Transmission Lines
Avoid short runs of straight line tubing. Straight line runs do not provide for expansion
and contraction due to pressure and/or temperature changes
Reduce stress in tube lines. Long tubing runs should be supported by brackets or clips.
Before operating the power unit, connections should be tightened securely and leak­free. Over tightening can cause premature thread failure or high pressure fittings to burst
Should a hydraulic hose ever rupture, burst or need to be disconnected, immediately
shut off the power unit and release all pressure. Never attempt to grasp a leaking pressurised hose with your hands. The force of escaping hydraulic fluid can inflict injury
Do NOT subject the hose to potential hazard such as fire, sharp objects, extreme heat
or cold or heavy impact
Do NOT allow the hose to kink, twist, curl, crush, cut or bend so tightly that the fluid
flow within the hose is blocked or reduced. Periodically inspect the hose for wear
Hose material and coupler seals must be compatible with the hydraulic fluid used.
Hoses also must not come in contact with corrosive materials such as battery acid, creosote-impregnated objects and wet paint. Never paint a coupler or hose
FAILURE TO HEED THESE WARNINGS MAY RESULT IN PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.
4.0 Installation
4.1 Familiarise yourself with the specifications and illustrations in this owner’s manual.
Know your power unit, its limitations and how it operates before attempting to use. Refer to the specification chart below or if in doubt, contact a Durapac representative.
DPA-18 Air Hyd. Power Unit - V1.0 www.durapac.com Page 4 of 11