Durant-Eaton Ambassador Series Data Sheet

April 2007
Counters, Panel Meters, Tachometers and Timers Count Control
Ambassador Series — Durant
®
43
Cat. No. 57601401
Features
8-digit totalizer
1/Tau ratemeter
Totalizer and ratemeter scaling
Four user-configurable control
inputs
Up to two output relays
Two solid-state outputs
RS-485 Serial communications
Feet/Inches control available
Standards and Certifications
UL Listed
CE Marked
Technical Data and Specifications
Power Input
AC Operation — 115V AC (±15%) std., 50 to 60 Hz,
7W
230V AC (±15%) opt., 50 to 60 Hz,
7W
DC Operation: 10 – 15V DC opt.,
300 mA maximum
DC Power Output
12V DC (±25%), 100 mA maximum
(includes all line and load varia­tions)
Environmental
Operating Temperature: 32 to 131°F
(0 to 55°C)
Storage Temperature: -4 to 158°F
(-20 to 70°C)
Operating Humidity: 85% Relative,
non-condensing
NEMA 4 rating when mounted with
gasket provided
Main Counter
Type: Bi-directional
Digits: 6
Presets: Varies by Model
Reset modes: Auto or manual reset
to zero or preset
Scaler Range: 0.00001 to 9.99999
Decimal Point: 5 positions, (6 on 4-
preset models)
Output Latency: See Table 40
Batch Counter
Type: Increment with main counter
recycle or final preset signal
Digits: 6
Presets: 1
Output Latency: < 1 mS
Totalizer
Type: Bi-directional, same or
opposite of main counter
Digits: 8
Scaler: Shared with main counter
Decimal Point: Tracks main counter
Count Input Speeds
See Tables 42 and 43
Count Inputs
Sink — Impedance: 4.6k ohms to +5V DC
Voltage —
High: 3.5 to 34.0 Low: 0.0 to 1.9V DC
Source (high) —Impedance: 2.3k ohms to
common
Voltage —
High: 3.5 to 17.0V DC (100% duty cycle) Low: 0.0 to 1.9V DC
Source (low) —Impedance: 2.3k ohms to
common
DC Voltage —
High: 0.6 to 17.0V DC Low: -17.0 to -0.6V DC
AC Voltage: 17V AC (48V Peak-
Peak) maximum
Control Inputs
Impedance: 4.7k ohms to +5V DC
Voltage —High: +3.7 to +24V DC
Low: 0.0 to 0.9V DC Response: Minimum low 15 mS,
minimum high 15 mS
Relay Outputs
Type: SPDT contacts
UL Ratings: 250V AC, 360V A Pilot
Duty
Transistor Outputs (2)
Type: NPN open collector with tran-
sient protection
Maximum Voltage (OFF state):
30V DC
Maximum Current (ON state):
200 mA @ 1.3V DC
Communication
Type: RS-485
Format: 1 start bit, 7 data bits
(ASCII), 1 parity bit, 1 stop bit
Protocol: Opto-22 compatible
Speed: 300, 1200, 2400, 4800, 9600
and 19200 baud
Parity: Odd, Even, None (space
transmitted, ignore received)
Rate Indicator (Not available on models 57601-415 and 57601-485)
Type: 1/Tau
Digits: 6
Presets: 2
Scaler Range: 0.00001 to 99999
Decimal Point: 5 positions,
programmable
Accuracy: ±0.015% of reading
Update Time: See Table 41
Zero Time: See Table 41
Connections
Type: Dual depluggable screw
terminal strips
Conductor Size: 14 – 22 AWG
(2.1 – 0.38 mm
2
), 600V, solid,
stranded, or fused (preferred)
PG05400001E For more information visit: www.eaton.com
44
Counters, Panel Meters, Tachometers and Timers Count Control
Ambassador Series — Durant
®
April 2007
Table 40. Output Latency for Ambassador Control
Style Number Output Latency
5760X401 5760X402 5760X403
5760X404 5760X405 5760X415
0.7 to 2 mS
0.7 to 2 mS
0.7 to 2.7 mS
0.7 to 2.7 mS < 1 mS < 1 mS
Table 41. Rate Indicator Specs for Ambassador Control
Style Number Update Time Zero Time
5760X401 5760X402 5760X403
5760X404 5760X405
5760X415
1 second, fixed 1 second, fixed 1 second, fixed
1 second, fixed
0.1 to 99.9 sec, programmable
0.1 to 999.9 sec, programmable
10 seconds, fixed 10 seconds, fixed 10 seconds, fixed
10 seconds, fixed
0.1 to 99.9 sec, programmable
0.1 to 999.9 sec, programmable
Table 42. Ambassador Count Input Speeds — 5760X405, 5760X415
Solid-State A or B A and B
A - B A + B
-A + B
A, B Dir 2A, B Dir A, B Rst
Quad x 1 Quad x 2 Quad x 4
Tot A/Cnt B Tot + Cnt B
Contact inputs = 40 Hz; B Direction inputs = 40 Hz and B Reset input = 10 μS Min. Low. Input A not active on Feet/Inches control.
8250/8250 8250/8250 8000/8000
8000/40 4500/40 8250
— — —
14000/9000 16000/8500
3000/3000 4000/4000 3000/3000
— — —
3250 3250 2000
6500/6500 6500/6500
Table 43. Ambassador Count Input Speeds — 5760X401, 5760X402, 5760X403, 5760X404
Mode Input A/B
Add/Sub Add/Add
Count/Direction Count x 2/Direction
Quadrature Quadrature x 2
The maximum count speed depends on the selected count mode. All maximum speeds are shown with square waves (50% duty cycle) input.
Maximum Speed
Solid-State (High Speed)
20 kHz 20 kHz
15 kHz
7.5 kHz
6.5 kHz
6.5 kHz
Contact (Low Speed)
40 kHz 40 kHz
40 kHz —
— —
For more information visit: www.eaton.com PG05400001E