DURACELL DURA PLUS 9V1 Datasheet

This data is subject to change. Performance information is typical. Contact Duracell for the latest information.
MN9VEURP0821
Page 1 of 2
Z
n/M
nO2
MN1604
Size: 9V
(6LR61)
Alkaline-Manganese Dioxide Battery
Z
n/M
nO2
Berkshire Corporate Park Bethel, CT. 06801 U.S.A. Telephone: Toll-free 1-800-544-5454 www.duracell.com
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the energy/service life that the battery will provide for various load conditions.
Nominal voltage
9 V
Impedance
1,700 m-ohm @ 1 kHz
Typical weight
46 g (1.7 oz)
Typical volume
22.8 cm
3
(1.4 in3)
Terminals
Miniature snap
Storage temperature range
6ºC to 29ºC (42ºF to 85ºF)
Operating temperature range
-18ºC
to
54ºC
Designation
IEC: 6LR61
USAGE GUIDE (Please refer to IEC60086.5 for detailed safety and storage specifications.)
(1) Insert batteries correctly with regard to the polarities (“+”/”-”) marked on the battery and the electrical appliances.
(2) Do not short-circuit, recharge, heat, disassemble the battery, or dispose of in fire.
(3) Do not mix use old batteries with new ones, or mix use batteries of different types, chemistries or brands.
(4) Exhausted batteries should be immediately removed from the equipment.
(5) Keep the batteries away from small children. Do not let the child remove/replace batteries without monitoring from adults.
(6) Storage temperature: 6~29, and humidity conditions RH: 40%~90%.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information.
MN9VEURP0821
Page 2 of 2
Z
n/M
nO2
MN1604
Size: 9V
(6LR61)
Alkaline-Manganese Dioxide Battery
Z
n/M
nO2
Berkshire Corporate Park Bethel, CT. 06801 U.S.A. Telephone: Toll-free 1-800-544-5454 www.duracell.com
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the energy/service life that the battery will provide for various load conditions.
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
0 50 100 150 200 250 300 350 400
Voltage (V)
Service Hours
Constant Current
2mA
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
0 2 4 6 8 10 12 14 16
Voltage (V)
Service Hours
Constant Resistance
180 Ohm
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
0 2 4 6 8 10
Voltage (V)
Service Hours
Constant Current
60 mA
250 mA
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
0 10 20 30 40 50 60
Voltage (V)
Service Hours
Constant Resistance
270 Ohm
620 Ohm