A. Front View, Back View and Dimensions
B. General Description
C. Specifications
D. Controls and Indicators
C. Capacitance Diaphragm Gauge Suppliers
IIIInstallation page 9
A. Unpack the Controller
B. Mount the Controller
C. Select the CDG
D. Connect the CDG
E. Attach the CDG Cable
F. Make Accessory Connections
G. Check Supply Voltage
H. Attach the Power Cord
IVOperation page 13
A. Turn Power On
B. Front Panel Controls
C. Set Pt 1 High
D. Set Pt 1 low
E. Set Pt 2 High
F. Set Pt 2 Low
G. Units mTorr/Torr/kTorr -- Bar/mBar/microBar -- Pascal/kPascal -- Arb
H. Calibrate
I. Full Scale
J. Zero
K. Reset of Stored (Default) Values
L. Set Point Operation
M. Reading Pressure
N. Analog Output
O. Serial Interface
P. Pascal/kPascal Pressure Units Only Set-Up (-J Mode)
WARNING!
Do not use the Model 908A Dual Capacitance Diaphragm Gauge Controller to measure the pressure of combustible gas mixtures. The gauge
normally operates at low temperatures, but it is possible that momentary transients or controller malfunction may cause ignition of combustible mixtures, which then might explode and cause damage to
equipment and injury to personnel.
Limitation on use of Compression Mounts
WARNING!
Do not use a compression mount (quick-connect) for attaching the
gauge tube to the vacuum system in applications that may develop positive pressures. Positive pressures may cause the tube to be blown out
of a compression fitting and damage equipment and injure personnel.
Chemicals
WARNING!
Many organic cleaning solvents, such as acetone, produce fumes that
are toxic or flammable. Use such solvents only in areas that are well
ventilated to the outdoors and away from electronic equipment, open
flames, or other potential ignition sources.
Please let us Know...
Terranova products are the most advance instruments of their type available
from any manufacturer. We have made this Instruction Manual as complete
and clear as possible. Let us know if you have any comments that can make
this manual or our products more useful.
The Terranova Scientific Model 908A Dual Capacitance Diaphragm Gauge (CDG) Controller
displays vacuum pressure as measured from capacitance diaphragm gauges. The 908A supplies
±15 volts at up to 0.75 amp; this is sufficient to operate most heated capacitance diaphragm gauges. The 908A precisely measures the 0 to 10 volt signal from the CDG to determine pressure.
Model 908A controller covers full scale ranges from 20 mTorr to 10,000 Torr. The 908A is
housed in a 1/8 DIN enclosure and is simple to operate.
C. Specifications
1. Useful Measuring Range
4 decades; for CDG tubes with full scale of 20 mTorr to 10.00 ktorr; full scale range selection is
entered on the front panel by the user
2. Display Range
-9.9 torr to 10.00 ktorr; pressures higher than 130% of Sensor Full Scale displays HI;
The
3. Display Resolution
varies according to full scale range, from 0.01 mTorr to 1 Torr
4. Gauge Interface
The 908A incorporates a high-resolution input circuit which allows the use of the capacitance diaphragm gauge over its entire 4 decades.
5. Input to the 908A Controller
0 to 10 volts for full scale of the gauge
6. Units of Display
torr (mtorr), mBar (Bar), pascal (kpascal), or arb (no units); user selectable
7. Full Scale
user selectable range to match CDG FULLSCALE : 20, 50, 100 mTorr; 1, 2, 10, 100, 1000, 5,000
and 10,000 torr
8. Calibration Adjust
for calibration of display; allows user to multiply CDG response by 0.50 to 2.00
9. Vacuum Gauge
one or two capacitance diaphragm gauges which have 1-10 VDC signal output and require up to
0.75 amp total from ± 15 volt supplies; this is sufficient to operate most heated gauges
used for adjustment of gauge and instrument parameters
4. Digital Display
4-digit 7-segment bright red LED, 10 mm high
5. Display Indicators
bright red individual LED for miscellaneous indicators
E. Capacitance Diaphragm Gauge Suppliers
CDGs may be ordered from several sources, including the following:
Duniway Stockroom Corp.
1305 Space Park Way
Mountain View, California 94043
USA
telephone(650) 969-8811
toll-free(800) 446-8811
facsimile(650) 965-0764
emailinfo@duniway.com
internetwww.duniway.com
MKS Instruments, Inc.
Six Shattuck Rd.
Andover, Massachusetts 01810
USA
telephone (978) 975-2350
toll-free (800) 227-8766)
facsimile (978) 975-0093
internet www.mksinst.com
Carefully unpack the Model 908A Dual Capacitance Diaphragm Gauge Controller. The shipment
includes these components:
• controller unit
• power cord
• mounting clips, fuses
• D-sub 15 ac
• this instruction manual
cessory connector
If your controller does not have all of these items, call Du
niway Stoc
kroom. If anything appears
to have been damaged in shipment, contact the shipper.
If you need a gauge cable for connection to the Model 908A, please contact Duniway Stockroom.
Do not plug the power cord in yet.
B. Mount the Controller
You can rest the controller unit on a bench, table top, or shelf, or you can mount it in a rack or
cabinet. The controller unit is housed in a standard 1/8 DIN box. If you are mounting the unit in
a panel, the cutout dimensions are 1.78 inch by 3.60 inch (45.2 mm by 91.4 mm), see fig. 3, page
9. One mounting clip attaches to each of the sides of the controller unit. To attach the clip, slide
the beveled surfaces of the clip under the cutout on the side of the box and push the clip toward
the back of the unit.
Be sure to leave enough clearance at the back of the controller unit for easy ac
cess to ca
nections.
C. Select the CDG
The Model 908A controller is designed to work with standard capacitance diaphragm gauges
which operate on ±15 volts. If you have difficulty obtaining a CDG, please contact us at Duniway
Stockroom.
ble con-
CAUTION
Use of a CDG other than those which operate from ±15 volts may cause
damage to the CDG.
9 of 29