Ausgabe / Edition: 07/2003Printed in Federal Republic of GermanyTeile-Nr.:/Part-No.: 0791 589001
Foreword
This instruction manual is intended to help the user to become familiar
with the machine and take advantage of its application possibilities in
accordance with the recommendations.
The instruction manual contains important information on how to
operate the machine securely, properly and economically. Observation
of the instructions eliminates danger, reduces costs for repair and
down-times, and increases the reliability and life of the machine.
The instruction manual is intended to complement existing national
accident prevention and environment protection regulations.
The instruction manual must always be available at the machine/sewing
unit.
The instruction manual must be read and applied by any person that is
authorized to work on the machine/sewing unit. This means:
–Operation, including equipping, troubleshooting during the work
The user also has to assure that only authorized personnel work on the
machine.
The user is obliged to check the machine at least once per shift for
apparent damages and to immediatly report any changes (including the
performance in service), which impair the safety.
The user company must ensure that the machine is only operated in
perfect working order.
Never remove or disable any safety devices.
If safety devices need to be removed for equipping, repairing or
maintaining, the safety devices must be remounted directly after
completion of the maintenance and repair work.
Unauthorized modification of the machine rules out liability of the
manufacturer for damage resulting from this.
Observe all safety and danger recommendations on the machine/unit!
The yellow-and-black striped surfaces designate permanend danger
areas, eg danger of squashing, cutting, shearing or collision.
Besides the recommendations in this instruction manual also observe
the general safety and accident prevention regulations!
General safety instructions
The non-observance of the following safety instructions can cause
bodily injuries or damages to the machine.
1. The machine must only be commissioned in full knowledge of the
2. Before putting into service also read the safety rules and
3. The machine must be used only for the purpose intended. Use of
4. When gauge parts are exchanged (e.g. needle, presser foot, needle
5. Daily servicing work must be carried out only by appropriately
instruction book and operated by persons with appropriate training.
instructions of the motor supplier.
the machine without the safety devices is not permitted. Observe all
the relevant safety regulations.
plate, feed dog and bobbin) when threading, when the workplace is
left, and during service work, the machine must be disconnected
from the mains by switching off the master switch or disconnecting
the mains plug.
trained persons.
6. Repairs, conversion and special maintenance work must only be
carried out by technicians or persons with appropriate training.
7. For service or repair work on pneumatic systems, disconnect the
machine from the compressed air supply system (max. 7-10 bar).
Before disconnecting, reduce the pressure of the maintenance unit.
Exceptions to this are only adjustments and functions checks made
by appropriately trained technicians.
8. Work on the electrical equipment must be carried out only by
electricians or appropriately trained persons.
9. Work on parts and systems under electric current is not permitted,
except as specified in regulations DIN VDE 0105.
10. Conversion or changes to the machine must be authorized by us
and made only in adherence to all safety regulations.
11. For repairs, only replacement parts approved by us must be used.
12. Commissioning of the sewing head is prohibited until such time as
the entire sewing unit is found to comply with EC directives.
13. The line cord should be equipped with a country-specific mains
plug. This work must be carried out by appropriately trained
technicians (see paragraph 8).
What items are supplied depends on your order. Prior to installation
please check that all the required parts are present.
–
1 head
–
2 operating panel
–
3 stand
–
4 pedal linkage
–
5 pedal
–
6 yarn stand
–
7 table plate
–
8 main switch
–
9 control box
–
10 maintenance unit
–
–
optional extras (depending on the order)
tools and minor components in the accessory kit
2.General and shipping braces
2
CAUTION:
The machine must be set up by trained specialist personnel.
All work on the electrical equipment of this special sewing machine
may only be carried out by qualified electricians or other appropriately
trained persons.
The mains plug must be removed.
Shipping braces
All shipping braces must be removed before the machine is installed.
–
Remove safety straps and battens on the machine head, table and
stand.
3
3.Installing the machine
3.1Adjusting the working height
The working height is continuously adjustable between 85 and 120 cm
(measured to the upper edge of the table plate).
–
–
–
1
2
3
Undo locking screws 1 and 2 on both sides of the stand.
Adjust the table of the machine to the required working height.
Tighten locking screws 1 and 2.
3.2Attaching the yarn stand
6
4
3
5
–
Insert the reel stand 3 in the hole in the table plate and secure it
with the nuts and washers.
–
Fit and align the yarn-reel bracket 5 and unwinding arm 3 as
shown in the illustration.
NB: the yarn-reel holder and the unwinding arm must be vertically
in line.
–
Depending on the type of yarn reel the centring piece 6 must be
set as shown in the above illustration. Incorrect settings may lead
to faults in operation.
6
4
3.3Aligning and connecting the pedal
1
2
3
4
5
–
Align the pedal 4 laterally on the stand brace 5 so that the middle of
the pedal is roughly beneath the needle.
–
Screw the pedal 4 firmly to the stand brace.
–
Screw the set value initiator 1 firmly to the stand brace.
–
Attach the pedal linkage 3 to the set value initiator 1.
–
Slightly undo clamping screw 2.
–
Adjust the pedal linkage so that when released the pedal 4 is at an
angle of about 10°.
–
Tighten clamping screw 2.
2
5
4.Electrical connection
1
2
3
4
CAUTION:
The mains voltage must coincide with the rated voltage specified on
the name plate.
The machine adapts the local mains voltage via connection terminals 1
to 5 and A to D of the transformers in the control box.
Both the transformer terminals are factory-set to a mains voltage of
230 V.
For different mains voltages the terminals must be connected as
follows:
Strip termin a l 2:
Voltagebluebrown-and-white
200VAB
230VAC
240VAD
On strip terminal 5 the brown-and-white and blue-and-white wire
jumpers must be changed. Both connection terminals are given in the
5
table.
Example:
“L-4" means place the wire jumper between terminals L and 4.
Strip termin a l 5:
Voltagebrown-and-white blue-and-white