NOTE:
A qualied electrician must carry out the electrical installation of this radiator. The
warranty could be invalid if these requirements have not been met.
The Vitro
Radiant / Convector Combination Heater
Instructions for Operation and Installation
(Read these instructions carefully and retain for further reference.)
Models:
VITRO 750 Black VITRO 1200 Black VITRO 1600 Black
VITRO 750 White VITRO 1200 White VITRO 1600 White
The Ducasa Vitro glass fronted designer heater provides a combination of radiant and convected heat and will grace any home. With touch sensitive adjustment and LCD display the Vitro can be used as a stand alone heater, as a part of a zoned pilot wire system (optional) or programmed via the Ducasa remote controller (optional).
Luxurious design with glass front panel (Black or White)
Double heating circuit: aluminium heater for convection heating and heating circuit on glass for radiant heat.
Designed and fabricated in accordance with EN60335-1 and EN 60335-2-30
NEC Class II
The radiator requires a 230/240V 50Hz power supply and is a double insulated product so does
not require an earth cable.
Wall mounted (by quick xing system)
On-off main switch
Electronic digital thermostat with LCD screen
Standby, Comfort and Anti-frost settings
2 Hour Turbo Mode
Keypad locking (anti-tamper) facility
Overheat protection
Connectable to a central programming system by pilot wire if required
Programmable by infrared control (Ducasa Remote) - optional
See Section “Installation Instructions – Location of Heater” for important notes regarding the siting of the appliance.
Due to the surfaces of the heater becoming hot, it must not be positioned directly against or below infammable surfaces.
Do not dry clothes or towels on the heater nor leave fabrics, magazines, spray cans, volatile substances or similar objects within 250mm of the heater.
In case of breakdown or damage turn off the appliance at the main On/Off switch and notify the supplier.
If the electricity cable gets damaged it must only be replaced by a technician appointed by the supplier. This will avoid possible risks and ensure that special tools are available if needed.
This appliance is not intended to be used by persons (incl. children) with limited physical, sensory or mental capabilities, or who lack experience, except for those under supervision or have received instruction in the use of the appliance from a person responsible for their security.
Children must be supervised in order to ensure that they do not play with the appliance.
WARNING: In order to prevent overheating, do not cover this appliance. There has to be free
movement of air around all surfaces of the appliance.
This symbol “DO NOT COVER”, is placed on the heater as a reminder to the user.
GENERAL INFORMATION
1. IMPORTANT INFORMATION
ELECTRICAL CONNECTION
A qualifed electrician must carry out the electrical installation of this radiator. The electrical installation must comply with the current UK regulations. Any claim on the warranty could be invalid if these requirements have not been met.
The radiator requires a 230/240V 50Hz power supply and is a double insulated product so does not require an earth cable.
CONNECTING WIRES
L = Live Brown N = Neutral Blue FP = Pilot Wire Black (if required for external programmer)
IF PILOT WIRE IS NOT REQUIRED INSULATE BLACK CABLE TO ENSURE IT DOES NOT COME INTO CONTACT WITH ANY OTHERS WIRES OR TERMINALS.
The connecting wires must be of the appropriate section, in regards to the length of cable, type of cable and power rating of the apparatus. The apparatus must be connected into a connecting box. We recommend that the connecting box is positioned 10cm to the right of the apparatus and at 15cm above the oor. According to regulations, the apparatus must be connected to the power supply by means of an all-pole circuit breaker with a contact gap of at least 3mm or by a thermal-magnetic circuit breaker.
LOCATION
The ideal place to site the Ducasa radiator is as close as possible to coolest wall in the room but it is not recommended to site the radiator on un-insulated exterior walls, in this case, the part of the wall behind the radiator should be insulated. In bathrooms, the radiators must not be sited inside the protected area. The control unit switches must not be reachable, directly or indirectly, by a person in the bath or shower. The radiator, under no circumstances, should be installed below an electric power point. Choose the location of the radiator in respect of the minimum distances that are indicated below.
3. INSTALLATION INSTRUCTIONS
2. TECHNICAL DATA
MODEL
Vitro 750 Vitro 1200 Vitro 1600
Power (w) 750 1200 1600
Voltage 230V /1Ph /50Hz
Dimmensions WxHxD(mm.) 670x500x110 840x500x110 1000x500x110
CLASS II II II
gure 2