Ducasa Richmond DPL 15, Richmond DPL 10, Richmond DP 450, Richmond DP 600, Richmond DP 900 Installation And Operation Manual

...
1
ADVANCED ELECTRIC HEATING
Richmond DPL & DP
Low Level & Full Height Thermal Electric Radiator
Installation and Operation Guide
Type Wattage No. of Fins Size (WxHxD) (mm) Net Weight (kg)
DPL 10 950 10 865 340 96 12.8 DPL 15 1425 15 1265 340 96 19.2 DP 450 450 3 310 575 96 6.1 DP 600 600 4 390 575 96 8.1
DP 900 900 6 550 575 96 11.8 DP 1200 1200 8 710 575 96 15.7 DP 1500 1500 10 870 575 96 19.3 DP 1800 1800 12 1030 575 96 25.7
Models
v10 20171214
E1400226
2
Installation
Main Principles
This appliance must be connected to a 230V 50Hz power supply. This appliance must be connected to a switched fused spur or a plug. Main installation must be provided by an omni­polar device where the distance between contacts must be a minimum of 3mm.
Power Cord Wires = Neutral (Grey or Blue)
Live (Brown)
Pilot-Wire (Black)
IF PILOT WIRE IS NOT REQUIRED INSULATE BLACK CABLE TO ENSURE IT DOES NOT COME INTO CONTACT WITH ANY OTHERS WIRES OR TERMINALS.
The replacement of the power cable, if necessary, should be completed by a qualied
electrician authorised by the importer.
Precautions to be Taken
The radiator must be placed far from any inammable material and should not be used by
unsupervised children.
The radiator should never be covered by clothes, other materials or objects. It should never be placed in enclosed spaces or areas which might prevent the free circulation of air around the radiator.
Important Safety Information
Whilst in operation, the appliance must not be covered to avoid over-heating. If the appliance is covered and the safety over-heat switch is activated, the element will need replacing. This is not covered by the warranty.
This appliance is a Class 2 double insulated appliance and should not be used or connected in the wet zone of a bathroom or kitchen. The appliance should be placed at a distance that makes it impossible for a person taking a bath or shower to touch the switches and thermostat unit.
Do not place the radiator under a power socket.
Should the appliance have to be repaired in the rst instance please contact the supplier of
the radiator.
The minimum distance needed to allow air circulation is 150mm.
This unit contains a precise amount of synthetic heating uid inside the ns which must only
be opened by the manufacturer.
The standard rules about recycling and removal of synthetic heating uid should be followed
once the appliance is no longer in use.
Children of less than 3 years should be kept away unless continuously supervised.
3
Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the applince in a safe way and understand the hazards involved.
Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
CAUTION — Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
4
Directions for the Installer
Installation should only be completed by a qualied professional.
Electric Power
The electrical circuits within your house should be of the correct type and size for the appliance wattage.
We recommend that the fused spur outlet is placed 10cm to the right of the appliance and 15cm
from the oor.
The appliance is supplied with approximately 1.5m of power cable without a plug. The electrical circuit should be isolated by means of an omni-polar cutting system either by a switch or magnetothermic protecting device.
Main Components
The Richmond DPL body consists of special cast aluminium ns, specically designed to ensure
a maximum rate of heat diffusion, the air circulation channels providing a very effective convection effect.
The aluminium body contains a special heat conducting uid, lled inside the ns with a unique
procedure assuring a bubble-free content for a total uniform and silent delivery of heat.
Fitting the Appliance
The appliance should be hung as close as possible to the coolest wall in the room, however it is not recommended to place it on a wall that is not properly insulated – if this is the case, the part of the wall behind the unit should be insulated.
In a bathroom, the appliance must be placed within the protected zone and should not be reachable, directly or indirectly by a person in the shower or bath.
The appliance should, by no means, be placed under a connecting plug.
To hang the radiator, place the radiator on the oor in the position it is to be installed. Locate the bracket above the radiator with the point on the bracket being between the rst and second element on both sides (gure 1.a). For radiators with more than 9 elements, the bracket should be placed between the second and third element (gure 1.b).
Figure 1.a Figure 1.b