Ducasa AVANT-DGP 350, AVANT-DGP 800, AVANT-DGP 1000, AVANT-DGP 1300, AVANT-DGP 1500 Operating And Installation Instructions

...
AVANT–DGP
Thermal Electric Radiator
Operating and Installation Instructions
(Read these instructions carefully and retain for future reference)
Models:
AVANT-DGP 350 AVANT-DGP 800 AVANT-DGP 1000 AVANT-DGP 1300 AVANT-DGP 1500 AVANT-DGP 1800
A qualified electrician must carry out the electrical installation of this radiator. The Electrical
installation must comply with the current UK regulations. Any claim on the warranty could be
invalid if these requirements have not been met.
2
CONTENTS
General / Important Information Page 3
Installation Instructions Page 5
Electrical Power Supply
Location of Radiator
Mounting of Radiator
Operating Instructions Page 8
Controls
Switching On
Setting the temperature
Selection Of Mode
Programming
Keypad Locking (Anti-Tamper)
Maintenance and Guarantee Page 12
3
GENERAL INFORMATION
The Avant DGP has a special cast aluminium body specifically designed to assure maximum rate of heat
radiation; the air circulation channels providing a very efficient convection effect.
Special heat conducting fluid in the aluminium body. A unique process provides bubble free filling so
that the fluid delivers warmth from the heating element in a totally uniform way, ensuring that the entire
surface of radiator provides comfortable heat.
Monotube heating element to ensure maximum heat output.
Designed and fabricated in accordance with EN 60335-1, EN 60335-2 and EN 55014 (regulations
for domestic appliances)
Standard colour White (RAL 9016)
Class I or Class II
Wall mounted (by quick fixing system)
Capillary safety limiter
On-off main switch (illuminated)
Overheat protection
Programmable digital control wi
th LCD display
Comfort, Economy and Frost Protection settings
Key-pad locking (anti-tamper)
Programmable by infrared remote control (Ducasa Remote) – optional
NTC electronic sensor
Fitted with connecting power cable 1450mm long (without a plug)
Technical Data
Avant-DGP 350 3 350 340 x 580 x 100
6.9
Avant-DGP 500 4 500 420 x 580 x 100
8
Avant-DGP 800 6 800 580 x 580 x 100
12
Avant-DGP 1000 8 1000 740 x 580 x 100
16
Avant-DGP 1300 10 1300 900 x 580 x 100
20
Avant-DGP 1500 12 1500 1060 x 580 x 100
24
Avant-DGP 1800 12 1800 1060 x 580 x 100
24
Important Information
See Section “Installation Instructions – Location of Heater” for important notes regarding the siting of the appliance.
Due to the surfaces of the heater becoming hot, it must not be positioned directly against or below inflammable surfaces.
Do not dry clothes or towels on the heater nor leave fabrics, magazines, spray cans, volatile substances or similar objects within 250mm of the heater.
In case of breakdown or damage turn off the appliance at the main On/Off switch and notify the supplier.
If the electricity cable gets damaged it must only be replaced by a technician appointed by the supplier. This will avoid possible risks and ensure that special tools are available if needed
This appliance is not intended to be used by persons (incl. children) with limited physical
, sensory or mental capabilities, or who lack experience, except for those under supervision or have received instruction in the use of the appliance from a person responsible for their security.
Children must be supervised in order to ensure that they do not play with the appliance.
WARNING: In order to prevent overheating, do not cover this appliance. There has to be free movement of air around all surfaces of the appliance.
This symbol “DO NOT COVER”, is placed on the heater as a reminder to the user.
4
MODEL Number of Fins Power Rating (W) Size (mm) Net Weight (Kg.)
Loading...