Ducasa 720 Installation Manual

Installation of the thermostat
First of all disassemble the thermostat. Take off the front cover, using a thin screwdriver, carefully press in the locks located on the upper and lower sides of the front cover pulling it out slightly.
Programmable Thermostat
Remove the cover. Remove the frame.
Place the device into the junction box and fasten it by means of at least two screws (preferably
located at the same horizontal level).
Assemble the thermostat acting in reverse order. Install the frame carefully ensuring that it closely fits to the device’s case. Then return the front cover to its place and press it ensuring that both locks are fixed. Make sure that the front cover is properly affixed.
Technical specification
Supply voltage
Maximum load current
Consuming power
Weight
Dimensions ....................................................................................... 80 × 80 × 52 mm
Time of setting storage when supply is disconnected
Ingress Protection
Floor mounting temperature sensor ................................................... NTC 6,8 k
Length of sensor connection cable
Allowable ambient air temperature
Allowable relative air humidity
Maintaining temperature range
Factory preset
................................................................................. 240/120 V AC , 50/60 Hz
...................................................................... 16 А
............................................................................................. 150 g
....................... 12 Month
............................................................................. IP20
.................................................... 2 m
................................................... +5 bis +40 °C
........................................................... 80%
........................................................ +5 bis +45
.................................................................................. +25
°
С
If you have questions, please contact:
Ducasa Clima C/. Venezuela, 33 08019 Barcelona Spain
8
°
С
Tel.: +34 93 247 86 30 Fax.: +34 93 245 57 81 info@ducasa.com www.ducasa.com
720
Important information for safe usage ...................................................... 1
Introduction .............................................................................................. 1
Function .................................................................................................. 2
Controls and display ............................................................................... 2
Start-up of the thermostat......................................................................... 2
Menu structure of the thermostat ............................................................ 2
Basic settings ......................................................................................... 3
Set the Language .................................................................................... 3
Set the date and the time ........................................................................ 3
Daily program ......................................................................................... 4
Setting the daily program ......................................................................... 4
Weekly program ..................................................................................... 5
Setting the weekly program .................................................................... 5
Control of the heating system operating conditions ................................. 6
Setting of the common parameters of the thermostat ............................. 6
Output of energy saving statistics data ................................................... 6
Warranty ................................................................................................. 7
720 installation manual ........................................................................... 7
Tools and materials required for thermostat installation .......................... 7
Installation of floor-mounting temperature sensors ................................. 7
Thermostat installation.............................................................................. 7
Preparation of electrical connections ...................................................... 7
Connection diagram ................................................................................ 7
Installation des Thermostats ..................................................................... 8
Technical specification ............................................................................. 8
Important information for safe usage
Thermostat:
Manufacturer's guarantee does not cover malfunctions caused by mechanical damage, improper installation, or exploitation for purposes, or under conditions, not provided by the User- and Installation Manual. Please keep in mind that the Installation Manual and the Connection Diagram are no replacement for the professional skill of the device installer. We recommend that you apply for professional service for the thermostat and heating system installation. Only qualified electricians should perform the connections and power networking of the device. Switch off power before connecting wiring to the thermostat or disconnecting the device for testing .
Start-up:
Don’t turn the newly built heating system on before the tile fixing mixture or cement -sand mortar layer are hardened. You can get the different hardening times from the manufacturer of your chosen building material. Turning on the heating system prematurely can lead to damage of the floor decorative cover and heating mats, or sections outage. In case of doubt contact your dealer or heating system manufacturer.
Introduction
Thank you for choosing the 720 thermostat, the new intelligent heating control system. With this product you will see how easy it is to maintain your comfort at a lower cost; it will take care of keeping your home warm and cozy all the time. Designed with innovation and inspiration, the new thermostat is highly reliable, and easy to set and use.
Separate settings can be programmed for different times of the day, whether or in or out. This unit allows programming in half hour time periods over a seven day period providing maximum operating choice. Before you start the installation, please read this manual carefully!
Table of content
1
Function
The 720 thermostat is designed for the control of electrical underfloor heating systems (heating mats or cable units) or other electrical indoor heating systems. It automatically maintains a specified temperature exactly when you need it. There is no need to think about your heating man­agement. You will never have to remember to turn it on. You only need to set the time when you need it, and the 720 thermostat will turn the heat on for you so far in advance that the required temperature will be achieved by the time you specify. The 720 thermostat is an intelligent and self­developing system. Its operation is based on its particular experience of heating your house, so it strives every time to execute your commands more and more precisely and efficiently. The thermostat is equipped with a large highlighted LCD-Display with extended indication that makes it very easy to use the device. 3 multifunctional control buttons are located under the display; a help string appears in the bottom part of the display which indicates the current function of the buttons. The highlight appears when pressing any button and turns off automatically 40 seconds after the last button is pressed. The 720 thermostat controls the temperature based upon data received from the floor temperature sensor (included in the package). The device displays two tem­peratures — the actual floor temperature and the « set by you» temperature. The display also shows the maintenance mode (continuous, daily or weekly schedule). In the bottom part of the display the current day and time are displayed. The device has self-diagnostics, and will display warning messages. You can set a limit of maximum floor temperature. The device
will also show energy saving statistics per day, per week or per month in the form of a percentage figure.
Controls and display
Display
Buttons
1 Current floor temperature (°C)
2 Preset floor temperature (°C) 3 Heating system is powered on 4 Operating mode symbol 5 + button for maintaining temperature increase 6 Button for device turn ON/OFF and menu functions
Start-up of the thermostat
The thermostat can be turned on after wiring connections are complete and tested. To turn the 720 thermostat ON/OFF press the middle button
[Button ] for not less than 3 seconds. Turning ON/OFF is accompanied by an appropriate animation on the display. After the 720 thermostat is turned on the basic indication appears
on the highlighted display.
The larger numbers (20°C) indicate the actual floor temperature, the figures in the upper left corner (23°C) show the floor temperature to be maintained (the «comfort» temperature), the sign in the upper right corner indicates the continuous temperature maintenance mode. This symbol informs you about the operation status of the heating system (the heating is powered when the symbol is visible).
When the 720 thermostat is turned on for the first time it starts working in the maintenance mode (factory setting +25°C). When turned on, with your selected settings, the 720 thermostat starts working in that mode and will retain those parameters until you change them.
You can change the preset floor temperature by pressing for increasing and for reducing. This value will remain set, as the comfort temperature in all the modes, until you change it again. To activate the device press, and hold, any button. The buttons are not active, i.e. their
first button pressed only «wakes up» the device and turns on the highlighting.
7 – button for maintaining temperature decrease
In the bottom indicator the current functions of the buttons are shown:
lowering of the preset temperature,
MENU enter into device's menu,
+ increasing of the preset temperature
Warranty
During the warranty period the customer has the right to get the product repaired or replaced due to faulty materials from the manufacturer on the condition that the manual guides to Installation and Operation of this device have been followed. The warranty policy does not cover thermostats with mechanical damage and in cases where the failure is a result of disregard for operating conditions provided in this Manual, and/or instruc­tions provided for device installation and electrical connections. Reclamations :In case of failure during the warranty period of the device the customer must immediately apply to the Manufacturer service center
or to the regional authorized representative.
Appendix
Delivery set 720 Thermostat
Floor mounting temperature sensor with connection cable (2 m) External terminal block for grounding line connection User- and installation manual
Packing box
720 thermostat installation manual
* Important: Switch off the power before connecting or disconnecting wiring to the thermostat. A qualified electrician trained to current Indoor
Electrical Equipment regulations must install all wiring. We strongly recommend that you NOT to install the thermostat in premises with high air humidity. It is prohibited to install the device in bathrooms, saunas, shower cubicles or pools. The thermostat controlling heating in these premises must be installed in a neighbouring “dry room”.
Please study this manual carefully before starting the installation.
Tools and materials required for thermostat installation:
- Corrugated plastic tube not less than 16mm in diameter; the length depends on the distance between the thermostat and the heating unit
- Standard junction box for wall mounting units
- Screwdriver
- Phase voltage indicator
Installation of floor-mounting temperature sensor
The floor temperature sensor is installed when you perform your heating element (mat or cable section) installation. The Sensor is connected to the thermostat via a junction box. Place the sensor in the corrugated plastic tube near its end, and seal this end of the tube to prevent penetration of water, tile fixing mixture or cement mortar during the installation of the heating system. The tube containing the temperature sensor must be located at the same level as the heating cable between two neighbouring passes of this cable. Place the tube in a prepared groove in the floor and
lead its other end to the place chosen for the thermostat or junction box location.
Thermostat installation
Preparation of electrical connections
Install the plastic junction box into the wall where the location of the thermostat is planned. Lead the power supply cable, the cold leads of the heating mat or section, and the temperature sensor cable, into the box.
Connection diagram
Menu structure of the thermostat
To control the device, and the setting of its working parameters, the thermostat is provided with a graphic menu, subdivided into parts according to their purpose of function. To enter the menu, press the Menu button in the main indication window of the thermostat. The name of menu subdivisions will be displayed.
The subdivisions can be browsed by pressing the and the buttons, in the following sequence:
To enter the required menu subdivision, press the button in this division. To return to the main menu press the button in the Save settings and exit division.
2
7
Loading...
+ 2 hidden pages