The MegaNETIMPRESS/C”arNETIMPRESS/NETIMPRESS next (hereafter called as
“NETIMPRESS”) is the in-circuit programmer that can perform high-speed on-board
programming of an microcomputer with built-in flash ROM or flash ROM connected to
external bus of a microcomputer.
AAA.YLC: License for Device A
BBB.YLC: License for Device B
The NETIMPRESS can support programming various devices by inserting the compact
module (hereafter called as “Control Module”), which contains programming firm data for
each microcomputer, into the programmer main unit.
The Control Module uses the Compact Flash (CF) card as its media.
You can add a target device to program by adding programming conditions to the Control
Module in a form of a license.
The NETIMPRESS can be also used as a stand-alone since programming conditions are
saved in the Control Module.
Also, you can control the programmer very flexibly from a PC, as it has the 100Base-Tx
interface. You can build up an automatically-controlled production line system by using the
Remote Package AZ491 that is available for an additional order.
1
2 Notes & Points
The Control Module is specifically designed and built for the NETIMPRESS programmer and
cannot be used for any other purposes. (A CF card commercially available cannot be used
as the Control Module.)
About this manual
This Startup Manual describes only the initial setup procedures required to perform
programming.
For detailed specifications of the NETIMPRESS main unit, Control Module, probe, software,
etc., see their relevant manuals.
This Startup Manual explains how to install the software, set up an IP address in the
NETIMPRESS main unit, add a license to the Control Module and file operation steps. This
Startup Manual describes the processes up to the step to control the programmer from a PC.
For the information on how to set up environments of each device and connection
information, which vary depending on each device, see the manual of the relevant manual of
the Control Module or probe.
Note:
The Control Module (CF card) is not added with the license when delivered. Be sure to add
the license (extension: YLC), which is provided in CD-ROM.
PC Requirements
The NETIMPRESS runs only on a Windows PC (Windows XP, and Windows7).
An Ethernet cable (10BASE-T, and 100BASE-TX) to connect the programmer and a PC is
a user-prepared item. (When you make one-to-one connection without using a hub, you
need a cross cable.)
The reader for the CF card (USB connection, for example) at the side of a PC is a
user-prepared item.
2
3 Checking Hardware and Software (Standard Package)
This chapter explains the standard package of hardware and software that will be provided
for the NETIMPRESS programmer. (The hardware and software to be provided may differ
depending on your environments.)
3.1 Hardware
The following items are included in the hardware package of the NETIMPRESS.
(1) NETIMPRESS main unit (AF320/AF420/AF520/AF620/AF430)
(2) AC adapter specially built for the NETIMPRESS
(/AC4P INPUT: 100V to 240V OUTPUT: 12V)
(3) Control Module (Media: Compact Flash (CF) card)
(4) CD-ROM: 1 to 2 pieces (License Pack, Utility) depending on a target device
(5) Target probe, adapter, etc., which vary depending on a target device
3
3.2 Software
The following items are included in the software package of the NETIMPRESS.
(1) AZ490 (Remote Controller to download the various files, execute the device functions
and set up various parameters)
(2) AZ482 (F/DF Sheet Generator to create a file to set up an IP address to the programmer
main unit and download the files)
(3) AZ481 (Key File Generator to create an ID code Key to communicate with a PC, and a
SUM file)
4
4 Installing the Software
The software to make the various settings to the NETIMPRESS programmer is available at
our website:
Download the following software from the above mentioned web site:
(1) AZ490 (Remote Controller)
(2) AZ482 (F/DF Sheet Generator)
(3) AZ481 (Key File Generator)
Since they are the self-expanding files, decompress them on a PC and install them.
Note:
When you complete installing them and if you choose the default setting, they will be
registered in [DTS INSIGHT Tools], which you can open by selecting [Start] → [Program].
5
5 Setting up IP Address to Programmer Main Unit
To set up an IP address to the programmer main unit so as to control it via Ethernet from a
PC, follow the below steps.
* As a stand-alone, you can set IP address by using FUNC E2 to E4. For how to operate
NETIMPRESS as a stand-alone, refer to a chapter “Setting Ethernet” of an instruction
manual.
(1) Start up the AZ482 (F/DF Sheet Generator) that has been installed on your PC.
(2) From the Menu bar, select [File] → [New] → [Communication].
6
(3) Enter IP address, port information, etc. to set up in the programmer main unit, and select
[File] → [Save As] and enter a file name with extension “.ycm” to save. (This file name
can be changed.)
Note:
[Default Gateway] does not have to be set up in most cases, just enter “0.0.0.0”. When using
the NETIMPRESS via a router, enter an address of the router.
* Enter 1000 for Port No. if there is no problem on the network.
(4) Copy the xxx.ycm file you created to right underneath the drive of the Control Module (CF
card) by using the card reader of the CF card.
(5) Insert the Control Module into the slot of the NETIMPRESS main unit and turn on the
power.
(6) The message “YCM DATA SET?” is displayed on the LCD of the NETIMPRESS main
unit. Then, press either “EXE1” or “EXE2”. (For Mega/C”arNETIMPRESS , press EXE1
and EXE2, both of them are the user-defined keys with no names.)