DTS SCENA LED 80 PC FC, SCENA LED 80 FR FC User Manual

SCENA LED 80 FC
Made in Italy
SCENA LED 80 FR FC
SCENA LED 80 PC FC
User’s Manual rel. 1.0 GB
D.T.S. Illuminazione s.r.l. – ITALY http://www.dts-lighting.it/
2
Le informazioni contenute in questo documento sono state attentamente redatte e
controllate. Tuttavia non è assunta alcuna responsabilità per eventuali inesattezze.
Tutti i diritti sono riservati e questo documento non può essere copiato, fotocopiato,
riprodotto per intero o in parte senza previo consenso scritto della D.T.S .
D.T.S. si riserva il diritto di apportare senza preavviso cambiamenti e modifiche
estetiche , funzionali o di design a ciascun proprio prodotto. D.T.S non assume alcuna
responsabilità sull’uso o sull’applicazione dei prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no responsibility will be taken for any errors. All rights are
reserved and this document cannot be copied, photocopied or reproduced, in part or
completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to
any of its products without prior notice. D.T.S. assumes no responsibility for the use or
application of the products or circuits described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées
avec le plus grand soin. Nous déclinons toutefois toute responsabilité en cas
d'éventuelles inexactitudes. Tous droits réservés. Ce document ne peut être copié,
photocopié ou reproduit, dans sa totalité ou partiellement, sans le consentement
préalable de D.T.S.
D.T.S. se réserve le droit d'apporter toutes modifications et améliorations esthétiques,
fonctionnelles ou de design, sans préavis, à chacun de ses produits. D.T.S. décline
toute responsabilité sur l'utilisation ou sur l'application des produits ou des circuits
décrits.
Las informaciones contenidas en este documento han sido cuidadosamente
redactadas y controladas. Con todo, no se asume ninguna responsabilidad por
eventuales inexactitudes. Todos los derechos han sido reservados y este documento
no puede ser copiado, fotocopiado o reproducido, total o parcialmente, sin previa
autorización escrita de D.T.S.
D.T.S. se reserva el derecho a aportar sin previo aviso cambios y modificaciones de
carácter estético, funcional o de diseño a cada producto suyo. D.T.S. no se asume
responsabilidad de ningún tipo sobre la utilización o sobre la aplicación de los
productos o de los circuitos descritos.
3
INDEX:
1- SYMBOLS ................................................................................................................. 4
2- GENERAL WARNING .............................................................................................. 4
3- GENERAL WARRANTY CONDITIONS .................................................................... 4
4- TECHNICAL FEATURES ......................................................................................... 5
5- ACCESSORIES ........................................................................................................ 6
6- IMPORTANT SAFETY INFORMATION .................................................................... 7
6.1 Fire prevention...................................................................................................... 7
6.2 Prevention of electric shock .................................................................................. 7
6.3 Safety ................................................................................................................... 7
6.4 Waste Electrical and Electronic Equipment directive ............................................ 7
7- INPUT / OUTPUT CONNECTIONS ........................................................................... 8
8- DMX SIGNAL CONNECTION ................................................................................... 9
8.1 DMX Addresses .................................................................................................. 10
8.2 Selecting the DMX address ................................................................................ 10
9- FIRMWARE UPDATING ......................................................................................... 10
10- DISPLAY FUNCTIONS ......................................................................................... 11
11- DMX PROTOCOL ................................................................................................. 17
4
!
1- SYMBOLS Graphic symbols used on this manual:
THIS SYMBOL INDICATES A HOT SURFACE
THIS SYMBOL INDICATES ELECTRIC SHOCK
RISK
THIS SYMBOL INDICATES GENERAL RISK
THIS SYMBOL MEANS YOU CAN PLACE THE
UNIT ON NORMALLY FLAMMABLE SURFACES
THIS SYMBOL INDICATES THE MINIMUM
DISTANCE TO BE KEPT BETWEEN THE UNIT
AND THE ILLUMINATED OBJECTS
THIS SYMBOL INDICATES THE EUROPEAN
COMMUNITY DIRECTIVE 2002/96/EC ON WASTE
ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE)
2- GENERAL WARNING
Read the instruction contained in this user manual carefully, as they give important information regarding safety during installation , use and maintenance. The device is not for domestic use and must be installed by a qualified electrician or experienced person. Always disconnect the device from the mains before maintenance. The device must always be equipped with an efficient ground connection.
3- GENERAL WARRANTY CONDITIONS
The unit is guaranteed for 36 months from the date of purchase against manufacturing material defects.
LED 30 cm
5
4- TECHNICAL FEATURES
OVERVIEW
SCENA LED 80 FC is a compact, lightweight, DMX-controlled LED projector equipped with an high-power Full Colour (RGBW) LED featuring 4 LED channels (Red / Green / Blue / White); 3660 Total Lumens. The unit in available in two models: SCENA LED 80 PC FC, featuring a Ø 90 mm PC lens, and a long excursion 10°-76° linear zoom with high-efficiency optical system, enabling it to be used as a PC Beam or a very wide Wash (4245 Lux / 2 m). SCENA LED 80 FR FC, featuring a Ø 112 mm Fresnel lens, and a long excursion 14°-77° linear zoom (3864 Lux / 2 m) with high-efficiency optical system. SCENA LED 80 FC is a modern alternative to conventional lights, improving light quality, flexibility of use and installation, energy savings and component duration. The fixture doesn’t heat up and the projection is always flicker free. The dimming curves are similar to those of halogen lamps. The connectors are Powercon In/Out and 5 poles DMX In/Out. SCENA LED 80 FC is contained in a strong housing with folded edges, designed to resist all the rigors of continuous use. Also, the yoke has an exclusive round flange + clutch system which guarantees a perfect grip and safer operation.
PRODUCT CODES:
03.TS026.03.A SCENA LED 80 FC *PC lens *White finishing
03.TS026.44.A SCENA LED 80 FC *PC lens *Grey Silver finishing
03.TS026.46.A SCENA LED 80 FC *PC lens *Black finishing
03.TS026.03.F SCENA LED 80 FC *Fresnel lens *White finishing
03.TS026.44.F SCENA LED 80 FC *Fresnel lens *Grey Silver finishing
03.TS026.46.F SCENA LED 80 FC *Fresnel lens *Black finishing
LED Technology 1 x FULL RGBW LED; 3660 Lumens
Optical group PC version (Ø 90 mm PC lens), 4245 Lux / 2 m, 10° - 76° linear zoom FR version (Ø 112 mm Fresnel lens), 3864 Lux / 2 m, 14° - 77° linear zoom
Control 10 DMX channels (Default) 4 digit 7 segments LED display + 4 soft keys
Connectors Power supply: Powercon In & Out connectors DMX: 5 poles In & Out connectors
Power supply Electronic full-range 90-260Vac , 50/60 Hz Consumption: max 90W
Weight
4 Kg (PC version) 3,7 Kg (FR version)
6
DIMENSIONS
5- ACCESSORIES
As standard
1 x User’s Manual 1 x POWERCON male cable connector (D.T.S. Code 0520P014) 1 x XLR 5 pins male cable connector (D.T.S. Code 0508B028) 1 x XLR 5 pins female cable connector (D.T.S. Code 0508B027) 1 x Filterframe for SCENA COMPACT *Black finish (D.T.S. Code 02M00422.46)
Optional (on request)
- “C” Clamp G50 (Max. Load. 10 Kg) *Black finish (D.T.S. Code 0521A012)
- “C” Clamp G60 (Max. Load. 50 Kg) *Black finish (D.T.S. Code 0521A004)
- Barndoor for SCENA COMPACT *Black finish (D.T.S. Code 03.TA206)
7
6- IMPORTANT SAFETY INFORMATION
6.1 Fire prevention:
It is permissible to place the unit on normally flammable surfaces. Suitable for mounting on normally flammable materials surfaces greater than 200°C with some combustion time lag. Minimum distance from the closest illuminable surface: 30 cm. Replace any blown or damaged fuses only with those of identical value (2AT).
6.2 Prevention from electric shock:
High voltage is present inside the unit. Unplug the unit prior to performing any operation which involves touching the inside of the unit. This equipment must be grounded, do not connect to non-grounded supplies. The use of a thermal magnetic circuit breaker is recommended for each SCENA LED 80 FC unit. Use only AC supplies 90-260V , 50-60 Hz. SCENA LED 80 FC should never be located in position exposed to rain or in areas of extreme humidity. A good air ventilation is essential for proper equipment work.
6.3 Safety:
The external surface of the unit may exeed 50°C; never handle the unit until at least 5 minutes have elapsed since the unit was turned off. Never install the unit in an enclosed area lacking sufficient air flow. The ambient temperature should not exeed 40°C and should not be lower than -10°C.
6.4 Waste Electrical and Electronic Equipment (WEEE) directive:
The machine, accessories and packaging should be sorted for environmental-friendly recycling. For EC countries: according to the European Directive 2002/96/EC for Waste Electrical and Electronic Equipment and its implementation into national right, luminaires that are no longer usable must be collected separately and disposed of in an environmentally correct manner.
!
8
7- INPUT / OUTPUT CONNECTIONS
FUSE 2AT
DMX OUTPUT XLR 5 Pins Female Panel Connector
MAINS AC
INPUT 90-260V, 50/60 Hz
DMX INPUT XLR 5 Pins Male Panel Connector
DISPLAY PANEL
MAINS AC
OUTPUT 90-260V, 50/60 Hz
MAX 16A
9
5
3
4 2
1
1=GND 2=DATA­3=DATA+
CONTROLLER S T A N D A R D D M X 5 1 2
DMX OUT DMX OUT
DMX IN DMX IN
DMX OUT
DMX IN
DMX OUT
8- DMX SIGNAL CONNECTION:
The unit operates using a digital DMX 512 signal. Connection between the controller and the unit or between units must be carried out using a two pair screened ø 0.5 mm. Ensure that the conductors do not touch each other. Do not connect the cable ground to the DMX connector chassis. The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first unit to the DMX IN plug of the second one. In this way, all the projectors are cascade connected.
If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX reception problem For Installations where long distance DMX cable connections are needed, we
suggest to use a DMX terminator. The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor Between pin 2 and 3. The DMX terminator must be plugged into the last unit (DMX out panel connector) of the DMX line.
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
1
2
3
5
4
OUT
120 ohm
PIN 3
PIN 2
Loading...