DTS SCENA LED 150 User Manual

Page 1
Made in Italy
SCENA LED 150
D.T.S. Illuminazione s.r.l. – ITALY http://www.dts-lighting.it/
Page 2
2
Le informazioni contenute in questo documento sono state attentamente redatte e
controllate. Tuttavia non è assunta alcuna responsabilità per eventuali inesattezze.
Tutti i diritti sono riservati e questo documento non può essere copiato, fotocopiato,
riprodotto per intero o in parte senza previo consenso scritto della D.T.S .
D.T.S. si riserva il diritto di apportare senza preavviso cambiamenti e modifiche
estetiche , funzionali o di design a ciascun proprio prodotto. D.T.S non assume alcuna
responsabilità sull’uso o sull’applicazione dei prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no responsibility will be taken for any errors. All rights are
reserved and this document cannot be copied, photocopied or reproduced, in part or
completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to
any of its products without prior notice. D.T.S. assumes no responsibility for the use or
application of the products or circuits described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées
avec le plus grand soin. Nous déclinons toutefois toute responsabilité en cas
d'éventuelles inexactitudes. Tous droits réservés. Ce document ne peut être copié,
photocopié ou reproduit, dans sa totalité ou partiellement, sans le consentement
préalable de D.T.S.
D.T.S. se réserve le droit d'apporter toutes modifications et améliorations esthétiques,
fonctionnelles ou de design, sans préavis, à chacun de ses produits. D.T.S. décline
toute responsabilité sur l'utilisation ou sur l'application des produits ou des circuits
décrits.
Las informaciones contenidas en este documento han sido cuidadosamente
redactadas y controladas. Con todo, no se asume ninguna responsabilidad por
eventuales inexactitudes. Todos los derechos han sido reservados y este documento
no puede ser copiado, fotocopiado o reproducido, total o parcialmente, sin previa
autorización escrita de D.T.S.
D.T.S. se reserva el derecho a aportar sin previo aviso cambios y modificaciones de
carácter estético, funcional o de diseño a cada producto suyo. D.T.S. no se asume
responsabilidad de ningún tipo sobre la utilización o sobre la aplicación de los
productos o de los circuitos descritos.
Page 3
3
INDEX:
1- SYMBOLS
4
2- GENERAL WARNING 4 3- GENERAL WARRANTY CONDITION 4 4- TECHNICAL FEATURES 5 5- MAIN ELECTRICAL CHARACTERISTICS 6 6- ACCESSORIES 7 7- IMPORTANT SAFETY INFORMATION 8
7.1 Fire prevention
7.2 Prevention of electric shock
7.3 Safety 8- INPUT / OUTPUT CONNECTIONS 8 9- DMX SIGNAL CONNECTION 9
9.1 DMX Addresses
9.2 Selecting the DMX address 10- FIRMWARE UPDATING 10 11- DISPLAY FUNCTIONS 11 12- SERVICE MENU 15 13- DMX PROTOCOL 16
Page 4
4
1- SYMBOLS Graphic symbols used on this manual
THIS SYMBOL INDICATES A HOT SURFACE
THIS SYMBOL INDICATES ELECTRIC SHOCK
RISK
THIS SYMBOL INDICATES GENERAL RISK
THIS SYMBOL MEANS “DO NOT PLACE THE
UNIT ON INFLAMMABLE SURFACES”
THIS SYMBOL INDICATES THE MINIMUM
DISTANCE TO BE KEPT BETWEEN THE DEVICE
AND THE LIT OBJECT
2- GENERAL WARNING
Read the instruction contained in this user manual carefully, as they give important information regarding safety during installation , use and maintenance. The device is not for domestic use and must be installed by a qualified electrician or experienced person. Always disconnect the device from the mains before maintenance. The device must always be equipped with an efficient ground connection.
3- GENERAL WARRANTY CONDITIONS
The unit is guaranteed for 36 months from the date of purchase against manufacturing material defects.
F
!
30cm
Page 5
5
4- TECHNICAL FEATURES
OVERVIEW
SCENA LED 150 is a compact, lightweight, DMX-controlled theatre projector featuring a single high-power White LED (3.000 °K), a Ø 120 m m PC or Fresnel lens, and a long wide excursion 8,2° - 70° (PC Version) or 12,8 ° - 62° (Fresnel Version) linear motorized zoom with high-efficiency optical system, enabling it to be used as a PC Beam or a very wide Wash.The unit is wireless ready. SCENA LED 150 is a modern alternative to conventional theatre lights, improving light quality, flexibility of use and installation, energy savings and component duration. In fact the fixture doesn’t heat up, and the projection is always flicker free. Also, the dimming curves are similar to those of halogen lamps. The connectors are Powercon In & Out and 5 poles DMX In & Out. SCENA LED 150 is contained in a strong housing with folded edges, designed to resist all the rigours of continuous use. Also, the yoke has an exclusive round flange + clutch system which guarantees a perfect grip and safer operation.
PRODUCT CODES:
03.TS016.A SCENA LED 150 *White 3.000 °K *PC BLACK
03.TS016.F SCENA LED 150 *White 3.000 °K *FR BLACK
03.TS016.AWS SCENA LED 150 *White 3.000 °K *With Wi reless on Board *PC BLACK
03.TS016.FWS SCENA LED 150 *White 3.000 °K *With Wi reless on Board *FR BLACK
03.TS017.A SCENA LED 150 *White 4.000 °K *PC BLACK
03.TS017.F SCENA LED 150 *White 4.000 °K *FR BLACK
03.TS017.AWS SCENA LED 150 *White 4.000 °K *With Wireless on Board *PC BLACK
03.TS017.FWS SCENA LED 150 *White 4.000 °K *W ith Wireless on Board *FR BLACK
03.TS018.A SCENA LED 150 *White 5.600 °K *PC BLACK
03.TS018.F SCENA LED 150 *White 5.600 °K *FR BLACK
03.TS018.AWS SCENA LED 150 *White 5.600 °K *With Wireless on Board *PC BLACK
03.TS018.FWS SCENA LED 150 *White 5.600 °K *W ith Wireless on Board *FR BLACK
Page 6
6
LED Technology 1 x White LED 3.000 °K, CRI>90, 7.000 Lumens Also available as 4.000 °K and 5.600 °K LEDs LED Max power: 150W
Optical group
Linear motorized zoom: PC Version (Ø 120 mm PC lens) from min 8,2° (1.600 Lux at 5 mt) to max 70° (185 Lux at 5 mt) Fresnel Version (Ø 120 mm Fresnel lens) from min 12,8° (800 Lux at 5 mt) to max 62° (250 Lux at 5 mt)
Control 4 DMX channels LED display + 4 soft keys Wireless ready
Connectors Power supply: POWERCON IN & OUT Connector DMX: 5 poles In & Out Connector
Power supply Electronic full-range AC 90-260 V 50 / 60 Hz
5- MAIN ELECTRICAL CHARACTERISTICS
Input Voltage Range : Vin 90 - 260 Vac Frequency : 50 / 60 Hz Power Consumption Range : 5 - 160 W Power Factor (Pf) : 0.95 electronic PFC controller Efficiency : 95% typical
Control Input:
Control Signal : DMX 512 Dimming System : Constant Current PWM Address Range : DMX 512 channels addressable by display
Page 7
7
6- ACCESSORIES
As standard
1 x User’s Manual 1 x POWERCON male cable connector (D.T.S. Code: 0520P014) 1 x XLR 5 pins male cable connector (D.T.S. Code: 0508B028) 1 x XLR 5 pins female cable connector (D.T.S. Code: 0508B027) 1 x Filterframe for SCENA LED 150 *Black finish (D.T.S. Code: 02M00416.46)
Optional (on request)
* “C” Clamp G60 (Max. Load. 50 Kg) *Black finish (D.T.S. Code: 0521A004) * “C” Clamp G60 (Max. Load. 50 Kg) *Chrome finish (D.T.S. Code: 0521A004.20) * Barndoor for SCENA LED 150 *Black finish (D.T.S. Code: 03.TBD01) * Ø 120 mm PC lens for SCENA LED 150 (D.T.S. Code: 0506P003) * Ø 120 mm Fresnel lens for SCENA LED 150 (D.T.S. Code: 0506P004) * Filterframe for SCENA LED 150 *Black finish (D.T.S. Code: 02M00416.46)
DIMENSIONS
Unit Dimensions Packing Dimensions (LxWxH) (LxWxH) 330 x 250 x 301 mm 300 x 235 x 425 mm
Weight Weight 5,3 Kg (PC version) 6,3 Kg (PC version) 5,1 Kg (Fresnel version) 6,1 Kg (Fresnel version)
250 mm
330 mm
281 mm
1 8 5
m m
3
0
1
m
m
Page 8
8
7- IMPORTANT SAFETY INFORMATION
7.1 Fire prevention:
Never locate the fixture on any flammable surface. Minimum distance from flammable materials: 10 cm. Minimum distance from the closest illuminable surface: 30 cm. Replace any blown or damaged fuses only with those of identical value (3,15 AT).
7.2 Prevention from electric shock:
High voltage is present inside the unit. Unplug the unit prior to performing any operation which involves touching the inside of the unit. This equipment must be grounded, do not connect to non-grounded supplies. The use of a thermal magnetic circuit breaker is recommended for each SCENA LED 150 unit. Use only AC supplies 90-260V, 50 / 60 Hz. SCENA LED 150 should never be located in position exposed to rain or in areas of extreme humidity. A good air ventilation is essential for proper equipment work.
7.3 Safety:
The external surface of the unit may exeed 50°C; ne ver handle the unit until at least 5 minutes have elapsed since the unit was turned off. Never install the unit in an enclosed area lacking sufficient air flow. The ambient temperature should not exeed 40°C and s hould not be lower than -10°C.
8- INPUT / OUTPUT CONNECTIONS
FUSE 3,15 AT
DMX OUT
XLR 5 Pins Male Panel Connector
MAINS AC INPUT
90-260V 50/60 Hz
DMX IN
XLR 5 Pins Female Panel Connector
DISPLAY PANEL
MAINS AC OUTPUT
90-260V 50/60 Hz (MAX 14 SCENA LED 150 UNITS @ 230V ; MAX 7 SCENA LED 150 UNITS @ 120V)
F
!
30cm
Page 9
9
9- DMX SIGNAL CONNECTION:
The unit operates using a digital DMX 512 signal. Connection between the controller and the unit or between units must be carried out using a two pair screened ø 0.5 mm. Ensure that the conductors do not touch each other. Do not connect the cable ground to the DMX connector chassis. The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first unit to the DMX IN plug of the second one. In this way, all the projectors are cascade connected.
If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX reception problem For Installations where long distance DMX cable connections are needed, we
suggest to use a DMX terminator. The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor Between pin 2 and 3. The DMX terminator must be plugged into the last unit (DMX out panel connector) of the DMX line.
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
1
2
3
5
4
OUT
120 ohm
PIN 3
PIN 2
5
3
4 2
1
1=GND 2=DATA­3=DATA+
CONTROLLER S TA ND AR D D M X 5 1 2
DMX OUT
DMX OUT
DMX OUT
DMX IN
DMX IN
DMX IN
DMX OUT
Page 10
10
9.1 DMX addresses
SCENA LED 150 can be controlled with 4 DMX channels. In order to use the unit in 4 channels, set the following addresses on the mixer:
Projector 1 A001 Projector 2 A005 If you want to select the next projector, just add “4” Projector 3 A009 ….. A…. projector 6 A021
9.2 Selecting the DMX address
1) Press the UP-DOWN key until you reach the required DMX address. The numbers on the display will start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the projector is now controlled by the new DMX address.
TIPS: if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a faster selection.
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the projector is now controlled by the new DMX address.
10- FIRMWARE UPDATING
Warning:
This procedure require a base knowledge of Windows computer applications. Please refer to an authorised D.T.S. service centre.
To update the software version of the SCENA LED 150 you need: D.T.S. RED BOX interface (D.T.S. Code: 03.LA.008). USB-DMX Driver for the D.T.S. RED BOX interface. D.T.S. Firmware upgrade utility program. (The driver and the installation procedure are available in our web site www.dts-lighting.it)
Updating the software version.
Please follow the procedure below to perform the update:
1. Install the D.T.S. RED BOX USB-DMX driver on the PC you will use to update the unit software.
2. Connect the D.T.S. RED BOX interface to the PC by using a USB cable.
3. Connect the D.T.S. RED BOX interface to the fixture by using a DMX cable.
4. Download the new software version into the unit by using D.T.S. Firmware upgrade utility program.
!
Page 11
11
Up-Dow n
MENU
ENTERUp-Dow n
Up-Dow n
ENTER
Up-Down
ENTER
ENTER
ENTER
ENTER
ENTER
Up-Down
Up-Dow n
MENU
ENTER
Up-Dow n
ENTER
ENTER
Up-Dow n
ENTER
ENTER
ENTER
11- DISPLAY FUNCTIONS
DISPLAY FUNCTIONS
The SCENA LED 150 display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the D.T.S. setting can vary the functions of the unit so that it does not respond to the DMX 512 used to control it. Carefully follow the instructions below before carrying out any variations or selections. NOTE: the symbol shows which key has to be pushed to obtain the desired function.
Software version 1.22
REVERSE DISPLAY Reverses display's reading depending on the mounting position (on the ground or suspended).
DISPLAY STAND BY To turn off the display (after 5 seconds) Or leave it always on.
DMX MODE To select DMX mode : 4 DMX channels mode (default), 2 DMX channels mode, 1 DMX channel mode or Manual mode. Manual mode can also be activated by pressing at the same time the “UP’’ + ”DOWN” buttons on unit display for 3 seconds (“A001”).
Suspended
Position
Floor
Position
Display
Off
Display
Always on
Default DMX Mode
4 Channels
Manual Mode
2 DMX channels mode 1 DMX channel mode
Page 12
12
With BOOST active, the LED’S current is set to Max value. (30% more gain compared to BOOST Off) Default = Enabled
Up-Down
MENU
ENTER
Up-Dow n
ENTER
Up-Dow n
Up-Dow n
Up-Dow n
ENTER
ENTER
ENTER
Up-Dow n
Up-Dow n
Up-Dow n
ENTER
Up-Dow n
ENTER
Up-Dow n
ENTER
Up-Dow n
ENTER
ENTER
ENTER
ENTER
ENTER
MENU
Up-Dow n
Up-Dow n
ENTER
ENTER
MENU
Up-Dow n
Up-Dow n
ENTER
ENTER
LED Led Min/Max, Smooth, Compression, Sync and Boost level values settings
LED MINIMUM VALUE This menu allow to select the minimum levels for white
LED MAXIMUM VALUE This menu allow to select the maximum levels for white
These settings have priority on Master Dimmer channel
SMOOTH VALUE This menu allow to select the value of the delay (in milliseconds) for Dimmer channel reaction to DMX or Program variation. Off = 25 ms. Instant response to DMX variation. 20 = 250 ms. Smooth response to DMX variation.
COMPRESSION This menu allow to select between Linear current output or Quadratic current output for LEDs Default = Quadratic
SYNC This menu allow to adjust the PWM frequency value (Hz) in order to reduce flickering in the process of your camera recordings
BOOST DRIVING This menu allow to increase the LED’s current from Min to Max
Linear = Linear Current output
Quadratic = Linear light output
Default = 0
Default = 100
Range = Off-20 Default = 4
Range = 610 Hz – 10 KHz Default = 610 Hz
Boost mode
activated
Boost mode deactivated
MENU
Up-Dow n
Up-Dow n
ENTER
ENTER
ENTER
INFRARED MODE Infrared remote control. By activating Ir Mode, it will be possible to navigate trought the unit functions by using the D.T.S. infrared remote control (D.T.S. Code: 0514L008)
Note: External infrared remote sensor needed (D.T.S. Code: 03.LA.016)
NOT IMPLEMENTED ON SCENA LED 150
DIMMER Dimmer intensity level (range 0-255) Active only if MODE = 1 DMX channel mode
ZOOM Zoom regulation (range 0-255) Active only if MODE = 1 DMX channel mode
Page 13
13
MENU Up-Down
Up-Dow nENTER
Up-Dow n
ENTER
ENTER
ENTER
ENTER
WIRELESS DMX
Wireless DMX enabled / disabled. By activating WDMX MODE, it will be possible to control SCENA LED 150 via D.T.S. ANTENNA Wireless DMX Transmitter (cod. 03.E1271). Active only on SCENA LED 150 with
Wirel
ess on board
Wireless Enabled
Wireless Disabled
UNLINK = LOG OUT
Logging on SCENA LED 150 (WIRELESS DMX must be enabled on SCENA LED 150 unit)
To log on the SCENA LED 150 in the WIRELESS system simply press and quickly release the function button on the transmitter. The transmitter will start flashing rapidly red/green scanning for new free receivers / SCENA LED 150 units. When a SCENA LED 150 logs on to the transmitter the LINK green light on transmitter starts to flash rapidly. After approximately 10 seconds the transmitter will jump back to normal mode and continue transmitting data. The SCENA LED 150 now try to synchronize to the transmitter. When synchronized to the transmitter, 2 different modes are possible:
1. Antenna transmitter has detected and transmits a DMX signal, in this mode a solid green light is seen on the transmitter and solid display is seen on SCENA LED 150.
2. No DMX signal connected, the Antenna transmitter will flash red/green; display blinking on SCENA LED
150. To log SCENA LED 150 off from a transmitter simply select UNLINK function under WIRELESS DMX MENU and press ENTER.
When SCENA LED 150 is logged off, the display is blinking, meaning its available for log in on a new transmitter.
Logging out a SCENA LED 150 Select UNLINK function under WIRELESS DMX MENU and press ENTER.
When SCENA LED 150 is logged off the display is blinking, meaning its available for log in on a new transmitter.
Logging out all SCENA LED 150units linked to a transmitter Press and hold the function button of the transmitter for about 3 seconds. When the display is blinking on
SCENA LED 150, it mean that the units are logged out.
Transmitter, Status LED Flashing red/green, no dmx connected. Solid green, dmx signal detected and transmitted. Fast flashing red/green, log in mode (every free SCENA LED 150 unit, not logged in to any other transmitter, will be logged on)
SCENA LED 150 Status Display blinking = not logged on to a transmitter (free). Solid display = logged on to a transmitter and receiving dmx data.
Page 14
14
MENU Up-Down
Up-Dow nENTER
ENTER
Up-Dow n
ENTER
ENTER
ENTER
EMERGENCY Emergency operating mode. By setting Emergency mode, it will be possible to select Dimmer intensity level that will then ran if DMX signal is missing or not available.
Usefull for Emergency EXIT
Default = 255
ENTER
ENTER
Up-Dow n
MENU
ENTER
ENTER
Up-Dow n
MENU
.
DEFAULT SETTING To restore default settings
TEMPERATURE Internal unit temperature visualisation
Internal unit temperature (° Celsius)
LIFE TIME This menu show the total unit life time and the LED life time
SOFTWARE Software version
Default = OFF
ENTER
Up-Dow n
ENTER
Up-Dow n
MENU
ENTER
ENTER
Up-Dow n
MENU
.
.
Page 15
15
12- SERVICE MENU
For technical personnel only
To operate this menu:
-Connect the unit to the main
-While reset is running, press the MENU and ENTER keys at the same time.
Up-Dow nE NTER
ENTER
ENTER
Up-Dow nENTER
.
ENTER
Up-Dow nEN TER
.
ENTER
Up-Dow nEN TER
.
ENTER
Up-Dow nEN TER
.
ENTER
Up-Dow nENTER
.
ENTER
Up-Dow nENTER
.
ENTER
CURRENT From min 20 mA to max 600 mA
Default = 300 mA
LENS PC or Fresnel lens selection
ZERO OFFSET From min 1 mm to max 50 mm
Default = 5 mm
RANGE From min 30 mm to max 150 mm Default = 103 mm
SPEED Maximum speed From min 1 mm/s to max 400 mm/s Default = 20 mm/s
ACCELERATION Maximum Acceleration/Deceleration From min 1 mm/s² to max 400 mm/s²
RATIO Transmission ratio. From min 10 mm/turn to max 200 mm/turn Default = 58.2 mm/turn
Up-Dow nENTER
ENTER
PRODUCT Product model selection SCENA LED 150 (Default) or PROFILO LED 150
Page 16
16
13- DMX PROTOCOL
4 CHANNELS MODE (Default)
1 SHUTTER / STROBE 2 DIMMER 3 ZOOM 4 RESET
DMX CHANNEL
1
Parameter:
SHUTTER
/ STROBE
DMX range
Value
Mid Point
DMX
value
Move Range
(degrees)
Mode
Option
Function
000-009
Black
-
out
010-019
Open
020-029
Black
-
out
030-119
Strobe
(from 3.27 s to 30 ms)
120-149
Pulse up (from 42.6 s to 120 ms)
150-179
Pulse down (from 42.6 s to 120 ms)
180-204
Random strobe
(Dimmer channel active)
205-229
Full independent Random Str
obe
(Dimmer channel disabled)
230-255
Open
DMX CHANNEL
2
Parameter:
DIMMER
DMX range
Value
Mid Point
DMX
value
Move Range
(degrees)
Mode
Option
Function
000-255
Proportional dimmer
DMX CHANNEL
3
Parameter:
ZOOM
DMX range
Value
Mid P
oint
DMX
value
Move Range
(degrees)
Mode
Option
Function
000-255
Linear ZOOM from Narrow to Wide
(8,2° - 70° PC lens ;
12,8° - 62° FRESNEL lens)
DMX CHANNEL
4
Parameter:
RESET
DMX range
Value
Mid Point
DMX
value
Move Range
(degrees)
Mode
Option
Function
000-015
No Effect
016-255
Zoom Motor Reset
(active after 3 sec.)
ENTER
ENTER
ENTER
RESM To restore service and user default settings
EXIT Exit from service menu
Page 17
17
2 CHANNELS MODE
1 DIMMER 2 ZOOM
DMX CHANNEL
1
Parameter:
DIMMER
DMX range
Value
Mid Point
DMX
value
Move Range
(degrees)
Mode
Option
Function
000-255
Proportional dimmer
DMX CHANNEL
2
Parameter:
ZOOM
DMX range
Value
Mid Point
DMX
value
Move Range
(degrees)
Mode
Option
Function
000-255
Linear ZOOM from Narrow to Wide
(8,2° - 70° PC lens ;
12,8° - 62° FRESNEL lens)
1 CHANNEL MODE
1 DIMMER
DMX CHANNEL
1
Parameter:
DIMMER
DMX range
Value
Mid Point
DMX
value
Move Range
(degrees)
Mode
Option
Function
000-255
Proportional dimmer
Page 18
18
NOTES
Page 19
19
NOTES
Page 20
20
The information contained in this publication has been carefully prepared and checked. However, no responsibility will be taken for any errors. All rights are reserved and this document cannot be copied, photocopied or reproduced, in part or completely, without prior written consent from D.T.S. D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits described herein.
D.T.S. Illuminazione s.r.l. – Via Fagnano Selve 10-12-14 47843
Misano Adriatico (RN) Italia
Tel.: +39 0541 611131. Fax + 39 0541 611111
info@dts-lighting.it www.dts-lighting.it
0517I197
MADE IN ITALY
ISO 9001:2008
D.T.S. quality system
is certified to the
ISO 9001:2008 standard
D.T.S. products are designed
and manufactured at the D.T.S.
plants in italy
0517I197
0517I1970517I197
0517I197