Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso
scritto della D.T.S .
DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di
design a ciascun proprio prodotto. D.T.S non assume alcuna responsabilità sull’uso o sull’applicazione dei
prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products
without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits
described herein.
PHARUS
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de .
D.T.S.
de design, sans préavis, à chacun de ses produits. décline toute responsabilité sur l'utilisation ou
Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado
D.T.S.
estético, funcional o de diseño a cada producto suyo. no se asume responsabilidad de
se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou
D.T.S.
sur l'application des produits ou des circuits décrits.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y
controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.
o reproducido, total o parcialmente, sin previa autorizaciónescrita de
se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter
D.T.S.
ningún tipo sobre la utilización o sobre la aplicació
n de los productos o de los circuitos descritos.
D.T.S
D.T.S.
3
ARC 1200
PHARUS
INDEX:
1- TECHNICAL FEATURES4
2- IMPORTANT SAFETY INFORMATION 6
2.1 Fire prevention
2.2 Prevention of electric shock
2.3 Protection against ultraviolet radiation
2.4 Safety
2.5 Level of protection against the penetration of solid and liquid objects
3- MOUNTING THE LAMP 7
3.1 Lamp alignment
4- VOLTAGE AND FREQUENCY8
5- INSTALLATION9
5.1 Protection against liquids
5.2 Movement
5.3 Risk of fire
5.4 Forced ventilation
5.5 Ambient temperature
6- MAINS CONNECTION10
6.1 Protection
7- OPENING THE PROJECTOR HOUSING 11
8- IRIS REPLACEMENT 12
9- PROJECTOR USE 13
9.1 Focus and Zoom
9.2 Iris and Dimmer
10- PERIODIC CLEANING 15
10.1 Lenses and reflector
10.2 Fans and air passages
11- PERIODIC CONTROLS 15
12- DISPLAY FUNCTION 16
13- HIDDEN MENU 17
4
1- TECHNICAL FEATURES
PHARUS is the latest evolution of the D.T.S. follow spots range.
PHARUS is a new follow spot ideal for all professional applications (theatres, concerts,
television studios, fashion displays, special events, etc).
PHARUS offers a distinct improvement in projection quality - thanks to a new optical
group with condenser lens.
PHARUS is available in two models: PHARUS 1500 (fitted with a 1500 W discharge lamp)
and PHARUS 1200 (fitted with a 1200 W discharge lamp).
PHARUS offers also a series of updated functions that ensure effective and creative use:
New customizable colour system (5 interchangeable gel filter holders);
Linear iris-diaphragm (extractable);
Linear zoom (7° to 16°);
Linear focus;
Mechanical dimmer with black-out.
PHARUS is designed to resist all the rigours of continuous use: the body is made in
aluminium and stainless steel, which offer high resistance to heat and mechanical stress.
PHARUS is complete with external ballast (electromagnetic or electronic).
New optical group with condenser lens
Zoom 7° ÷ 16°
Linear focus
Extractable iris-diaphragm
Mechanical dimmer with black-out
Colours
Colour changer (optional): 5 interchangeable gel filter holders
Automatic switching system between colours
Gobos
Gobo holder for gobo projections (optional)
Construction
Made on aluminium and stainless steel
High resistance to heat and mechanical stress
Removable cover for easy access to lamp
Safety
Safety microswitches
Power supply
220-240V 50/60Hz electromagnetic ballast version
90V-260V 50/60Hz electronic ballast version
Power consumption 1600 VA, with built-in power factor correction
External ballast (electromagnetic or electronic)
Weight
21,2 Kg (PHARUS); 22,8 Kg (PHARUS with colour changer);
7 Kg (electronic ballast)
19 Kg (electromagnetic ballast).
ARC 1200
PHARUS
Dimensions (LxWxH)
Projector (996 x 381 x 466mm)
Projector with colour changer (1108 x 381 x 466mm)
Ballast: electromagnetic (300 x 251 x 269mm), electronic (400 x 251 x 220mm)
996 mm
m
m
6
381 mm
46
Projector Packaging
Dimensions (LxWxH)
1200 x 450 x 500 mm
Weight
23,2 Kg
Ballast Packaging Dimensions
(LxWxH)
350 x 300 x 310 mm
Weight
20,5 Kg electromagnetic
8,5 Kg electronic
6
ARC 1200
PHARUS
2- IMPORTANT SAFETY INFORMATION
2.1 Fire prevention:
PHARUS 1500 uses a Osram HTI 1500W/D7/60
PHARUS 1200 uses a Osram HMI 1200W/S
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if
there is any doubt.
-Connect the unit to mains power via a thermal magnetic circuit breaker.
2.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves
touching the inside of the moving head, including lamp replacement.
-The level of technology inherent in the PHARUS requires the assistance of specialised personnel for all
servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
2.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses or filters are damaged. Their respective shielding functions
will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
2.4 Safety:
-The external surface of the unit, at various points, may exceed 70°C. Always wear suitable hand
protection when handling the unit.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should
not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
2.5 Level of protection against the penetration of solid and liquid objects:
-The projector is classified as an ordinary appliance and its protection level against the penetration of
solid and liquid objects is IP 20.